1 / 15

The Microcirculation

The Microcirculation. Figure 16-1; Guyton and Hall. Structure of Capillary Wall. Figure 16-2; Guyton and Hall. Interstitium and Interstitial Fluid. Figure 16-4; Guyton and Hall. Determinants of Net Fluid Movement across Capillaries.

lis
Download Presentation

The Microcirculation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Microcirculation Figure 16-1; Guyton and Hall

  2. Structure of Capillary Wall Figure 16-2; Guyton and Hall

  3. Interstitium and Interstitial Fluid Figure 16-4; Guyton and Hall

  4. Determinants of Net FluidMovement across Capillaries • Capillary hydrostatic pressure (Pc)-tends to force fluid outward through the capillary membrane. • Interstitial fluid pressure (Pif)- opposes filtration when value is positive. Figure 16-5; Guyton and Hall

  5. Determinants of Net FluidMovement across Capillaries • Plasma colloid osmotic pressure ( c)- opposes filtration causing osmosis of water inward through the membrane • Interstitial fluid colloid pressure ( if) promotes filtration by causing osmosis of fluid outward through the membrane NP = Pc -  c - Pif +  if Figure 16-5; Guyton and Hall

  6. Plasma Proteins and ColloidOsmotic Pressure • 75% of the total colloid osmotic pressure of plasma results from the presence of albumin and 25% is due to globulins. gm/dl p(mmHg) Albumin 4.5 21.8 Globulins 2.5 6.0 Fibrinogen 0.30.2 Total 7.3 28.0

  7. Determinants of Net FluidMovement Across Capillaries Figure 16-5; Guyton and Hall • Filtration rate = net filtration pressure (NFP) multiplied by the filtration coefficient • Filtration coefficient (Kf) is a product of surface area times the hydraulic conductivity of membrane

  8. Forces Causing Filtration at theArteriole End of the Capillary mmHg Forces tending to move fluid outward: Capillary pressure 30 Negative interstitial free fluid pressure 3 Interstitial fluid colloid osmotic pressure 8 TOTAL OUTWARD FORCE 41 Forces tending to move fluid inward: Plasma colloid osmotic pressure 28 TOTAL INWARD FORCE 28 Summation of forces: Outward 41 Inward 28 NET OUTWARD FORCE 13

  9. Forces Causing Reabsorption at the Venous End of the Capillary mmHg Forces tending to move fluid inward: Plasma colloid osmotic pressure 28 TOTAL INWARD FORCE 28 Forces tending to move fluid outward: Capillary pressure 10 Negative interstitial free fluid pressure 3 Interstitial fluid colloid osmotic pressure 8 TOTAL OUTWARD FORCE 21 Summation of forces: Outward 21 Inward 28 NET INWARD FORCE 7

  10. Net Starling Forces in Capillaries mmHg Mean forces tending to move fluid outward: Mean Capillary pressure 17.3 Negative interstitial free fluid pressure 3.0 Interstitial fluid colloid osmotic pressure 8.0 TOTAL OUTWARD FORCE 28.3 Mean force tending to move fluid inward: Plasma colloid osmotic pressure 28.0 TOTAL INWARD FORCE 28.0 Summation of mean forces: Outward 28.3 Inward 28.0 NET OUTWARD FORCE 0.3

  11. Net Starling Forces in Capillaries • Net filtration pressure of .3 mmHg which causes a net filtration rate of 2ml/min for entire body. Figure opener; Guyton and Hall

  12. Question Utilizing the data below, calculate the rate of net fluid movement across the capillary wall: Pressures (in mmHg) Plasma colloid osmotic = 20 Capillary hydrostatic = 20 Venous hydrostatic = 5 Arterial = 80 Interstitial hydrostatic = -5 Interstitial colloid osmotic = 5 Filtration coefficient = 10 ml/min/mmHg a. 0 ml/min d. 100 ml/min (Reabsorption) b. 10 ml/min (Filtration) e. 10 ml/min (Reabsorption) c. 100 ml/min (Filtration)

  13. Lymphatic System

  14. Determinants of Lymph Flow • The degree of activity of the lymphatic pump • smooth muscle filaments in lymph vessel cause them to contract • external compression also contributes to lymphatic pumping Figure 16-11; Guyton and Hall

  15. Determinants of Lymph Flow Interstitial fluid hydrostatic pressure Lymph Flow Figure 16-9; Guyton and Hall Figure 16-10; Guyton and Hall

More Related