Cryomodule Concepts & Cryogenics

Cryomodule Concepts & Cryogenics. J.D. Fuerst SPX Technical Study Group Meeting 27-29JUL10. SPX Layout. JLab 100mA Cryomodule Design J. Preble, JLab. RT HOM loads inside vacuum vessel. ELBE/ALICE ERL Cryomodule P. McIntosh, STFC Daresbury Laboratory.

liv
Download Presentation

Cryomodule Concepts & Cryogenics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cryomodule Concepts &Cryogenics J.D. Fuerst SPX Technical Study Group Meeting 27-29JUL10

  2. SPX Layout SPX Technical Study Group Meeting J.D. Fuerst

  3. JLab 100mA Cryomodule DesignJ. Preble, JLab • RT HOM loads inside vacuum vessel SPX Technical Study Group Meeting J.D. Fuerst

  4. ELBE/ALICE ERL CryomoduleP. McIntosh, STFC Daresbury Laboratory SPX Technical Study Group Meeting J.D. Fuerst

  5. Heavy Ions: TRIUMF ISAC-IIR. Laxdal, TRIUMF • Low-b drift tube-loaded quarter wave cavities • Common beam & insulating vacuum spaces SPX Technical Study Group Meeting J.D. Fuerst

  6. Heavy Ions: ATLAS • b=0.15 DTL QWR • Separated beam & insul. vac. SPX Technical Study Group Meeting J.D. Fuerst

  7. JLab SPX Cryomodule Concept (1)J. Henry, JLab • Based on CEBAF/SNS/12GeV Upgrade Evolution • Shown with internal HOM loads SPX Technical Study Group Meeting J.D. Fuerst

  8. JLab SPX Cryomodule Concept (2)J. Henry, JLab SPX Technical Study Group Meeting J.D. Fuerst

  9. Cornell ERL Injector Cryomodule (1): Cold MassM. Liepe, Cornell SPX Technical Study Group Meeting J.D. Fuerst

  10. Cornell ERL Injector Cryomodule (2): TTF EvolutionM. Liepe, Cornell SPX Technical Study Group Meeting J.D. Fuerst

  11. Cornell ERL Injector Cryomodule (3): CM SupportM. Liepe, Cornell SPX Technical Study Group Meeting J.D. Fuerst

  12. Cornell ERL Injector Cryomodule (4): AlignmentM. Liepe, Cornell SPX Technical Study Group Meeting J.D. Fuerst

  13. Cornell ERL Injector Cryomodule (5): MaintenanceM. Liepe, Cornell SPX Technical Study Group Meeting J.D. Fuerst

  14. Refrigeration (1) HELIUM PURIFIER HELIUM GAS STORAGE MAIN COMPRESSOR MAIN COLDBOX LN2 STORAGE LHE STORAGE SUB ATM COLDBOX 4.6K SUPPLY SHIELD SUPPLY LP RETURN SHIELD RETURN CRYOMODULE CRYOMODULE SPX Technical Study Group Meeting J.D. Fuerst

  15. VC WC VC T1 HX2 T2 HX3 CC2 CC1 HX4 JTHX JT1 JT2 CRYOMODULE Refrigeration (2) • Pressure stability • Vibration • Off-design operation • System margin • Upgradeability • Safety • Reliability • Efficiency • Cost/delivery • Similar systems HX1 LN2 T3 DIST SYS 80K SHIELD SPX Technical Study Group Meeting J.D. Fuerst

  16. Schneider, Kneisel, Rode, “Gradient Optimization for SC CW Accelerators,” PAC2003 Refrigeration (3) • Refrigeration @4.3K: • COPINV = 70 W/W • Carnot efficiency = 30% • Input power required = 230 W per watt at 4.3K • Refrigeration @2K: • COPINV = 150 W/W • Carnot efficiency = 18% • Input power required = 830 W per watt at 2K SPX Technical Study Group Meeting J.D. Fuerst

  17. ELBE CryoplantFZ-Rossendorf • Cryoplant hall: 17m x 10m • 220W @ 1.8K + 200W @ 80K, upgradeable to 380W with more comp & LN2 precooling • 417kW at full load (220W) SPX Technical Study Group Meeting J.D. Fuerst

  18. Cryoplant Costs • Requirements are calculated using data from T. Smith, 03MAY10: • 312W for Q=1E9 • 200W for Q=3E9 • 161W for Q=1E10 • 152W for Q=2E10 • Same Qs, but ½ voltage • Equivalent load includes 300W for 5-8K intercepts and distribution sys. losses and 200W equivalent for 40-80K shield load. This extra load is a fixed value and assumed to be independent of the 2K load. • For cryoplants of this type, 1.8K operation adds 33% to plant size compared to 2.0K operation. *Fermilab is buying a new cryoplant for ILC string tests. Design capacity is 270W@2K + 300W@5-8K + 4500W@40-80K (= 1230W equivalent at 4.5K). Costs scale with the 0.7 power of plant capacity (per Byrns & Green, “An update on estimating the cost of cryogenic refrigeration,” 1998). SPX Technical Study Group Meeting J.D. Fuerst