Continuous Emission Monitors (CEMS) Advancements From Measuring HCl and Ammonia (NH3) to using Sensitive Moisture Measurements for Identifying Boiler Tube Leaks. Ronald L. Baker Robert Peters Edul Chikhliwala EcoChem Analytics. Introduction & Overview.
E N D
Continuous Emission Monitors (CEMS) Advancements From Measuring HCl and Ammonia (NH3) to using Sensitive Moisture Measurements for Identifying Boiler Tube Leaks Ronald L. Baker Robert Peters EdulChikhliwala EcoChem Analytics
Introduction & Overview • Stack Monitoring Systems are already at plants to measure “acid gases” (NOx & SO2) and often CO, O2 & CO2 • Note: Stack moisture content, %H2O, typically measured as well • New or pending regulations in certain industries can require additional measurements: • HCl Hydrogen Chloride : another acid gas • NH3 Ammonia : related to ammonia/urea injection
MC3 Measurement Capability Gas Range Interval** CO 0-5 PPM to 0-10,000 PPM Single MC3 analyzer can measure 8 gases plus Oxygen SO2 0-10 PPM to 0-1,000 PPM NO 0-5 PPM to 0-500 PPM NO2 0-5 PPM to 0-500 PPM CO2 0-1,000PPM to 0-40% NH3 0-5 PPM to 0-500 PPM Dualranges can be selected for same gas HCl 0-10 PPM to 0-100 PPM H2O 0-2% to 0-50% * All components at 185C or above; standard sample cell path 12 meters ** User can select appropriate range within the range interval * Use of a short path cell can permit higher concentration ranges O2 0-25% N2O 0-10 PPM to 0-1,500 PPM CH4 0-10 PPM to 0-1,000 PPM
Moisture Measurements to Identify Boiler Tube Leaks • Since 2004, there have been 8 of these hot-wet analyzers installed at seven different waste coal fired facilities. • In addition to pollutant measurements of NOx, SO2, CO and diluents measurements of oxygen (O2) and carbon dioxide (CO2), these analyzers continuously monitor the concentration of moisture (H2O) in the flue gas stream. • This moisture measurement, similar to the other measurements, is updated every 7-10 seconds and has been shown to be effective in identifying and or verifying a boiler tube leak. • In the event of a tube leak, the increase in moisture can be fairly significant from the unit’s baseline moisture levels, ranging from a 1-3%+ increase. Therefore in a unit with a typical moisture level of 6.5%, a rather sudden increase to 8.5% moisture has confirmed boiler tube leaks. • Correlations improve after each event
HCl, Ammonia and Water Calibration “Wet” Calibrations with the Hovacal unit Hot-Wet Vapor Mixture Supply Unit Evaporator Mass Flow Controller Temperature Control Mass Flow Meter Pump Liquid Carrier Gas Solution (pure water, NH3 or HCl) Balance (Optional)
MC3 Installations - HCl • Wasatch Integrated Waste Mgmt • 2 waste to energy units • Wheelabrator Falls – PA • 2 waste to energy units • Chemical & Waste Treatment Industry worldwide - 15+ analyzers including Eli Lily & Company
MC3 Installations – NH3 • TransCanada – Ocean State Power – RI • 4 units on gas turbines with SCR • Wheelabrator Falls – PA • 2 waste to energy units-evaluating de-NOx system • Fertilizer and Chemical Industry in USA - 20 analyzers including Rentech Nitrogen, PCS, & CF Industries
HCl Dedicated CEMS • Major Utility in Texas • Installation near Dallas
Question and Answers EcoChem Analytics www.ecochem.biz