Cooling & mechanics

Cooling & mechanics. Georg Viehhauser (recycling material from Steve McMahon). Stability (from LOI back-up draft). Short timescale: No major disturbing events from external causes (magnet ramps, intended or unintended cooling system stops etc.)

lluvia
Download Presentation

Cooling & mechanics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cooling & mechanics Georg Viehhauser (recycling material from Steve McMahon)

  2. Stability (from LOI back-up draft) • Short timescale: • No major disturbing events from external causes (magnet ramps, intended or unintended cooling system stops etc.) • From ATLAS experience: ~24h. Corresponds to the timescale of a track-based alignment cycle. • Typical load variations during this timescale are • External vibration (relevant at time scales of up to 1s), • Power fluctuations of the front-end electronics of about 10%, • Temperature variations at any given position of ±1°C. • In present tracker typically a stability of 1µm was achieved during these periods (in rφ) • For future tracker we require the same performance over this timescale. • Medium timescale: • Timescale over which we currently gather enough data to constrain the weak modes. • During these periods (relatively infrequent) external perturbations can occur, which include • Magnet ramps, • Cooling system cycles, • Power and HV cycles, • Temperature variations at any given position of ±3°C, • Relative humidity variations between 10% and 50% at the operating temperature. • Based on ATLAS experience, this timescale is about one month. • In the present tracker typically a stability of 10µm was achieved during these periods. • For future tracker we require the same performance over this timescale. • Long timescale: • Stability against relaxation caused by creep, possibly accelerated by irradiation. • The timescale is months to years. • Require that the detector positions satisfy the same criteria as in the original placement requirements

  3. What have we achieved (short timescale)? Example: SCT Barrel as measured with FSI LHC fill

  4. What are the load changes (short timescale)? • Changes in front-end electronics power consumption • Rate-dependent • Reduced by L1 levelling • Different run types (calibrations etc.)? • Estimate is that front-end power constant within 10% • That defines an overhead in cooling power • Also need to understand potential temperature changes due to change in return line pressure drop • Example: type I pipe (ID 3.6, 2.2mm) for 5.88g/s: ΔT changes by 13% between x=0.5 and 0.45 at -38°C, so if we assign 9°C equivalent ΔT for all lines from start of evaporator to accumulator and scale naively we get ~1°C variation. This has to be absorbed by the structures. • This is in addition to the local temperature changes because of the changed power load • Are there any other sources of temperature variation in the cooling system (sink temperature,…)?

  5. What have we achieved (medium timescale)? This is driven by ‘seismic events’ • Cooling system stops, magnet quenches, power outages, etc…

  6. Cooling stoppages • An example: Cooling Stoppages in 2011 • A total of 19 stops of the evaporative cooling • 3 scheduled stops Maintenances of the plant by ENCV • 16 un-scheduled stops • 11 due to “external” influences (external to the cooling plant) • 1 fake smoke alarm • 1 Toroid fast dump • 6 power cuts • 2 failures in related systems (ID cable cooling & TRT FE cooling) • 1 fake DSS signal • 5 due to “internal” influences • 3 Minor (failure of TCs x 2 {119,162} + 1x trip of a circuit breaker) • 2 Major (water in filter, massive leak in pressure reducer)

  7. Thermal shocks • Apart from causing deformations, there is evidence which could link them to damage to the systems • Local supports and front-end electronics incl. all connections need to be able to withstand them • Due to proximity of pipes this applies also for all type I connections (incl. PP1) • Design thermal isolation of critical passive components (electrical connectors etc.) from cooling pipes • Prototype • In present system shock at turn-on and stop (lower than operating temperature because small return line pressure drop) • In 2PACL turn-on is more gentle (system loaded with liquid before temperature ramp-down), I suspect turn-off can be controlled similarly, but we need to be prepared to deal with unscheduled cooling stops Pixel module failures Time

  8. Summary • Feedback to local support community • Your structures must be stable at the μm scale for variations of the heat load of 10% and evaporation temperature changes of 1°C • Your structures must be able sustain thermal shocks (all power off, front-end and cooling) and remain stable to 10μm • Feedback to cooling community • Your system needs to keep the evaporation temperature stable on short time scales to 1°C • You should do everything to prevent thermal shocks