240 likes | 545 Views
PillCam ™ COLON. Case Demonstrations. PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006. Case I. 46-year old male Rectal bleeding, change in bowel habit. Sample Cases.
E N D
PillCam™ COLON Case Demonstrations PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case I 46-year old male Rectal bleeding, change in bowel habit SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy image PillCam image Case I SampleCases Colonoscopy: 4 mmpedunculatedpolyp (tubular adenoma) at sigmoid PillCam capsule endoscopy: Polyp (<6 mm) at sigmoid PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case II 65-year old female Chronic diarrhea SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
PillCam images Case II SampleCases Colonoscopy: Large tubulo-villous polyp with severe dysplasia. Patient referred to surgical intervention (findings verified). PillCam capsule endoscopy: Large rectal neoplastic tumor PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case III 69-year old male Colorectal cancer (CRC) screening SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
PillCam images Case III SampleCases Colonoscopy: Normal PillCam capsule endoscopy: 5 mm polyp at sigmoid. Patient referred to repeat colonoscopy. PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy image PillCam image Case III SampleCases Repeat Colonoscopy: 5 mm adenomatic polyp identified at sigmoid and removed. PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case IV 58-year old male Positive FOBT SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy image PillCam image Case IV SampleCases Colonoscopy: 14 mm pedunculated polyp (villous adenoma) at sigmoid PillCam capsule endoscopy: Large (>9 mm) polyp at sigmoid PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case V 62-year old male Surveillance due to history of polyps SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy image PillCam image Case V SampleCases Colonoscopy: 4 mmpolyp at sigmoid (tubular adenoma) PillCam capsule endoscopy: Polyp (<6 mm) at sigmoid-rectum, and more… PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
PillCam images Case V SampleCases PillCam capsule endoscopy: <6 mm plyp at transverse 6-9 mm polyp at left colon PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case VI 58-year old male Rectal bleeding SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy images PillCam images Case VI SampleCases Colonoscopy and PillCam capsule endoscopy: Spread diverticulosis PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case VII 75-year old female Positive VC: 17x22 mm polyp at sigmoid Referred to colonoscopy / polypectomy SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
PillCam image Colonoscopy image Case VII SampleCases Colonoscopy: Carcinoma at sigmoid. Patient referred to surgical intervention PillCam capsule endoscopy: Large neoplastic tumor at sigmoid PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case VIII 53-year old female Rectal bleeding SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy image PillCam image Case VIII SampleCases • PillCam capsule endoscopy: • 6-9 mm polyp at sigmoid • Colonoscopy: • 8 mm polyp at sigmoid • 5 mm polyp at transverse PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Case IX 48-year old female Blood in stool and anemia SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
PillCam images Case IX SampleCases Colonoscopy: Normal PillCam capsule endoscopy: Two polyps (<6 mm) at descending colon PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy images PillCam images UlcerativeColitis SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
Colonoscopy images PillCam images Polyp (~10 mm) at Transverse SampleCases PillCam™ COLON has received a CE Mark, but is not cleared for marketing or available for commercial distribution in the USA. UEGW 2006
The End UEGW 2006