An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electrical Cable Aging: What does IAEA Recommend? Module 2 Dr. John H. Bickel Evergreen Safety & Reliability Technologies, LLC

  2. Objective is to Understand.. • Recommendations of TECDOC-1147 regarding aging management of electrical cables. • Aging management program process • Types of cables previously investigated and aging mechanisms considered • General recommendations for tests, inspections, and maintenance programs

  3. IAEA TECDOC-1147 • Title: “Management of Aging of I&C Equipment in Nuclear Power Plants” • Prepared by experts from US, UK, France, Germany, Finland • Findings/recommendations reviewed by countries with large nuclear programs (Russia, Czech, Slovak Republics, India, others) • Purpose: “guide worldwide nuclear industry on potential effects of I&C aging on plant safety and economy” • Identify “means available to minimize or eliminate any detrimental effects of aging”

  4. Aging Management Program Essentials: • Identify components whose aging may impact safety • Determine aging mechanisms important to safety and consequences of this aging • Identify tests, inspections and evaluation criteria for detection of safety component aging • Establish testing and replacement strategies to assure NPP operates safely over intended lifetime.

  5. General Observations: • Electrical cable experience indicates cable aging problems generally less significant than for other types of I&C components. • Under normal operating conditions, electrical cable lifetimes exceed most other active components. • Under accident conditions, potential for common cause failure considered serious enough to warrant further investigations.

  6. Mechanisms Which Aggravate Cable Aging: • Elevated local temperatures • Humidity, moisture ingress • Mechanical Stresses due to cyclic loads • Radiation Exposure

  7. Tests, Measurements for Assessing Aging • Chemical testing of insulation composition • Mechanical testing of insulation ductility • Electrical resistance testing of cable conductors and insulation • All of these tests are based on measurements of degradation in aged cables compared to a “base-line” sample.

  8. Recommended Methods Used to Monitor Cable Aging • Visual examinations of insulation (cracking) • Hardness testing of small cable section • Chemical analysis of sample section of cable • Measurement of resistance of insulation • Microscopy examinations of cable insulation samples • Swept frequency tests to measure dielectric properties (instrumentation cables) • Time domain reflectrometry (TDR) of conductor cable and connectors • AC/DC conductor resistance measurements