260 likes | 1.23k Views
Logger Net 3.4.1. Introduction. Logger Net 3.4.1 is a latest version of Support Software for many Campbell Scientific Inc. (CSI) Data loggers. It enables users to setup, configure and retrieve data from a network of Campbell Scientific Data loggers
E N D
Logger Net 3.4.1 Introduction Logger Net 3.4.1 is a latest version of Support Software for many Campbell Scientific Inc. (CSI) Data loggers. It enables users to setup, configure and retrieve data from a network of Campbell Scientific Data loggers It supports both Edlog and CRBasic Data loggers Edlog Data loggers CRBasic Data loggers CR500, CR510, CR10, CR10X, 21X, CR23X, CR7 CR200/205, CR800, CR3000, CR1000, CR5000, CR9000 Old (current data logger at GBC) New (future data logger at GBC)
Requisites for CR1000 • Power Supply: 12 V (nominal) • Software Support: PConnect 3.1, PC400, PC200W 3.0, Logger Net • Data logger Program File: .CR1 Logger Net 3.4.1, Logger Net Admin, Logger Net Remote, Logger Net-SDK, Logger Net Server-SDK, Logger Net Linux Can be created by three different ways For uploading software (sending program file to data logger from computer) to CR1000, we need the program file written in CRBasic code, i.e. extension file .CR1 Note: Program written for CR10X in Edlog (.CSI/.DLD files) is not supported by CR1000
Creating CR1000 program (.CR1 file) Logger Net 3.4.1 provides three different software applications to write the data logger program (.CR1), the only file type that is compatible with CR1000 data logger 1. Short Cut: Program generator 2. CRBasic: Program editor 3. Transformer Utility: Programming Code Converter Note: Logger Net 3.4.1 also provides Edlog editor for many other different kinds of data loggers
Logger Net 3.4.1 Main Menu For CR10X data logger For both data loggers For CR1000 data logger Data download Sending .CR1 file to data logger from computer Connect/Disconnect
Short Cut (SCWin) • Excellent choice for the beginning data logger programmer for creating data logger programs quickly and easily • Generates a program for user (for almost all of Campbell Scientific’s data loggers) which can be imported to CRBasic editor (also to Edlog) and can be directly sent to our data logger • It’s an application which also generates wiring diagram for the sensors connection to the data logger However …. • NOT suitable • for complex applications that require more control over measurement programs • for programs that require to support all of the functionality in Campbell Scientific data loggers
Short Cut main menu For new sensor-measurement set-up For adding/removing sensors in existing program
CRBasic: Campbell Recorder Basic -- similar to BASIC programming instruction code CRBasic Editor CRBasic Editor is a text editor programming tool that facilitates creation and modification of ASCII text files that constitutes the CR1000 application program. Intended for use by experienced data logger programmers who need more flexibility and control over data logger operation that what can’t be achieved using SCWin Note: CRBasic code - Case Insensitive
CRBasic main menu Writing/Editing window for CRBasic Code
Transformer Utility It’s a tool for transforming Edlog program file (.CSI /.DLD) to CRBasic program file (.CR1) Specially for those who are switching to CRBasic data loggers from Edlog data loggers Transformer utility is not installed on the logger net window, instead it is installed in separate window which can be opened from Start | Programs | LoggerNet | Utilities | Transformer
Transformer main menu Source CR10X file Converted CR1000 file
Source and Converted Files CR1000 file CR10X file Action Log: Comments about the problems in Converted file
Program Files: CR10X Vs CR1000 SMTEST.CSI SMTEST.CR1 Text files: SMTEST.CSISMTEST.CR1
Downloaded data from CR1000 Soil Moisture data in LAB Measurement Index Text file: http://www.geocities.com/sanjayaworld/smexpt01.txt
Soil Moisture Data Calibration EC5 Soil Moisture ~ Volumetric Water Content (VWC) ( % ) (m3/m3) Multiplier Sensor Output Offset Newly applied Calibration VWC = 0.00103 x mV – 0.334 ---- Potting Soil VWC = 0.000507 x mV – 0.0394 ---- Rockwool VWC = 0.00119 x mV –0.400 ---- Mineral Soil Soil Moisture Data Now & Then Text file: http://www.geocities.com/sanjayaworld/08Jun02_sm.txt Excel file: http://www.geocities.com/sanjayaworld/08Jun02_sm1.xls
List of Components for new weather station Component List
Questions ? Presentation slides available on http://www.geocities.com/sanjayaworld/loggernet.ppt