An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TOP Server: Understanding Modbus for Device Connectivity Presenter: Kevin Rutherford

  2. Modbus Protocol TrainingAgenda • Overview • Modbus Protocol Specifics • Modbus Types • Modbus Terminology • Modbus “Quirks” • Example Modbus packets • TOP Server Modbus Suite Flexibility • Supported Protocols • Dealing with “Non-Standard” Modbus Devices • Live Modbus Demo • Configuration • Troubleshooting • Using Quick Client • Using Channel Diagnostics • Questions?

  3. What is a Protocol? • Protocols can happen at many levels and cover many things • Cabling • Electrical • Packet structure • Content of Packets • Timing of Packets • Rarely does ONE protocol cover all of these things • Multiple protocols involved in making a full connection

  4. Application Protocols – Modbus TCP = Contents of the Train Cars Network Protocol Transport – TCP/IP Ethernet, FTP, HTTP = The train and cars Physical Transport Media- RS-232, RS-422, 10-Base-T = The Train Tracks What is a Protocol? Analogy – Train Tracks, Cars, & Cargo • RS-232, 485, Ethernet define cabling and electrical protocols, i.e. the Train Tracks… • In Ethernet connections, the transport defines the Train Cars (Packet structure) • In Serial connections, the application protocol usually defines the Train Cars • What’s in the Train Cars (packets) is the Cargo – the data – which is defined by the actual device/application protocol….

  5. Parts of a Typical Application Protocol • Many application protocols use some or all of these in their structures: • Header/start characters • Target Device ID • Function Code, Sub-Function Codes • Data Length • Data • Checksum/error checking • Termination character • Data section usually contains • Read: Memory type, start location, length, or multiple locations in some protocols • Write: Memory type & location to write, size to write, actual data to write • Data contents is usually driven by what Function Code or Sub-Function Codes are used in the request • Data is OFTEN communicated in Hex – Base 16!!!!

  6. Modbus – Used Everywhere! • Schneider/Modicon/Telemecanique PLCs • Nearly every other PLC brand offers built-in Modbus or a Modbus option module • Electrical transmission & distribution control & monitoring equipment • Water/wastewater control equipment • Temperature controllers • AC Variable Speed Drives • Servo Drives • Pick a device – it just might support Modbus • When in doubt – find out – is Modbus a choice on the hardware?

  7. Modbus Types • Serial – RS-232/422/485 electrical protocol • Two possible transmission modes: • Modbus RTU • Modbus ASCII • Proprietary – Vendor specific electrical protocol • Modbus Plus • Ethernet – standard TCP/IP Ethernet electrical +transport • Modbus TCP or Modbus Ethernet • Ethernet Encapsulated Modbus RTU or ASCII • Gateway Devices • Ethernet or Modbus Plus • Modbus RTU or ASCII serial on other side • Multiple serial devices on downstream side

  8. Modbus Terminology • Memory Types & Addressing • Input coils = Digital inputs • 1xxxxx address type • 0/1 values • Boolean data type • Output Coils = Digital outputs • 0xxxxx address type • 0/1 values • Boolean data type • Input Registers = Analog inputs • 3xxxxx address type • 16-bit registers • 32-bit data types use two consecutive registers • Holding (Output) Registers = Analog outputs • 4xxxxx address type • 16-bit registers • 32-bit data types use two consecutive registers

  9. Modbus Terminology • Read/Write Access • Read Only: Input registers & Input Coils • Read/Write: Output Coils and Holding Registers • Addressing – 5 or 6 digits • Original Modbus was 5 digits – i.e. 40001 • As PLC memories grew, went to 6, i.e. 400001 • Offset • Modbus address offset is all digits after the first digit identify which memory type the address is • Can be 0 or 1 based • Pointer that specifies where into that memory type to go and start getting data or writing data

  10. Modbus Terminology • Modbus Node Address • Used with serial devices • Each device on serial connection has unique ID • Slave ID values = 1 to 247 • Master’s don’t have a Node address • Modbus Function Codes • Used by Modbus Masters to tell a Modbus Slave what they want it to do • Read or Write? • Memory Type? • Single item or Multiple Items in a Transaction

  11. Modbus Terminology • Common Modbus Function Codes • 01 – Read Coils (output coils), 0xxxxx memory • 02 – Read Discrete Inputs (input coils), 1xxxxx memory • 03 – Read Holding Registers, 4xxxxx memory • 04 – Read Input Registers, 3xxxxx memory • 05 – Write Single coil (outputs), 0xxxxx memory • 06 – Write single Holding Register, 4xxxxx memory • 15 (0x0F) – Write multiple coils (outputs) • 16 (0x10) – Write multiple Holding Registers

  12. Modbus Terminology • Modbus Exception Codes • Used by slaves to tell Master what it did not like about a request • Examples: • 02 - Bad memory address • 01 - I don’t understand this function code • 0x0B - Slave didn’t respond – gateway devices

  13. Common Modbus Quirks • Data Byte Ordering • 32 bit data type word order • 64 bit data type Dword order • Byte order within words • Addressing – 0 or 1 based • Function Code support • Use of user definable function codes • Non-Modicon use of memory type + offset for addressing in documentation confusing

  14. Modbus RTU Packet Framing • PDU = protocol data unit • Address field – 1 byte – node address of the slave • CRC = error checking calculation, 2 bytes • Function Code + Data depends on what you want to accomplish.

  15. Modbus Packet FormatModbus RTU • A MODBUS message is placed by Modbus Master into a serial frame that has a known beginning and ending point. • This is an amount of time indicating to devices that receive a new frame to begin at the start of the message, and to know when the message is completed. • In RTU mode, message frames are separated by a silent interval of at least 3.5 character times. Character time= time to send one byte @ chosen baud rate

  16. Modbus RTU ExampleRead Holding Registers 108-110 from Slave Node 01 • Transmit: TX: 01 03 00 6B 00 03 xx xx • Receive: RX: 01 03 06 02 2B 00 00 00 64 xx xx xx xx = 2 byte checksum IMPORTANT Notice: • Request is in # of registers • Response is in # of bytes • 1 Register = 2 bytes

  17. Modbus RTU ExampleWrite Single Holding Register 2 with value of 3 on Slave Node 1 xx xx = 2 byte checksum • Transmit: TX: 01 06 00 01 00 03 xx xx • Receive: RX: 01 06 00 01 00 03 xx xx

  18. Modbus RTU ExampleException Response • Master asks for memory address that doesn’t exist in the slave

  19. Modbus Packet FormatModbus TCP • A Modbus TCP Packet is put into a TCP/IP wrapper • Notice similarity to Modbus RTU with function code + data • MBAP Header=Modbus Application Protocol Header – similar to the address field in the serial framing • MBAP = 7 extra bytes on beginning of transmission

  20. Modbus TCP MBAP HeaderContents • Unit identifier used when using bridging to downstream serial devices. 0 = no bridging being used

  21. Modbus TCP - Example • Reading Input Register 30070, Reading through a gateway to slave device ID 1 on serial connection • Request: • TX: 08 3B 00 00 00 06 01 04 00 46 00 01 • 08 3B 00 00 00 06 01 = MBAP • 08 3B = Transaction ID • 00 00 = Protocol ID • 00 06 = 6 bytes follow from here • 01 = Node ID 1 • 04 00 46 00 01 = regular Modbus Read input Registers command • 04 = Function Code • 00 46 = Starting address in hex 0x46 = 70 decimal = offset into input registers • 00 01 = Quantity of input registers to read • Response • RX: 08 3B 00 00 00 05 01 04 02 01 23 • 08 3B 00 00 00 05 01 = MBAP • 08 3B = Transaction ID – notice this matches the request • 00 00 = Protocol ID • 00 05 = 5 bytes follow from here • 01 = slave ID 1 • 04 02 01 23 = regular response to Modbus Read Input Registers • 04 = Function Code • 02 = byte count • 01 23 = Value in hex = 291 Decimal

  22. TOP Server Modbus Suite Flexibility • Protocols Supported • Modbus RTU Serial Master and Slave • Modbus ASCII Master • Modbus Plus • Modbus TCP Ethernet Master and Slave • Flexible Settings for Non-Standard Modbus • Zero or One-Based Addressing • Holding Register Bit Mask Writes • Specifying Function Code for Writes • Data order manipulation

  23. Live Demo • Overview • Modbus Protocol Specifics • Modbus Types • Modbus Terminology • Modbus “Quirks” • Example Modbus packets • TOP Server Modbus Suite Flexibility • Supported Protocols • Dealing with “Non-Standard” Modbus Devices • Live Modbus Demo • Configuration • Troubleshooting • Using Quick Client • Using Channel Diagnostics • Questions?

  24. Questions? • Questions later? • Kevin Rutherford • krutherford@softwaretoolbox.com • 704-849-2773 x1326 • support@softwaretoolbox.com • TOP Server Modbus Suite (Info / Free Demo) • http://www.toolboxopc.com/html/modbussuite.html • Other learning opportunities • Visit www.softwaretoolbox.com/webinars