Resistive Shimming for Higher Homogeneity Magnets in the MagLab’s DC Magnet User Program Mark D. Bird, Florida State University, DMR 0603042.
E N D
Resistive Shimming for Higher Homogeneity Magnets in the MagLab’s DC Magnet User ProgramMark D. Bird, Florida State University, DMR 0603042 The Series-Connected Hybrid Magnet (SCH) being developed at the MagLab will provide an unprecedented magnetic field of 36 T with 1 ppm homogeneity over a 10 mm diameter spherical volume (DSV). To accomplish this level of homogeneity at such a high field, new water-cooled shim coils are being developed (above). Prototypes recently tested in the MagLab’s Keck magnet successfully demonstrated a world-record value of 5.6 ppm over 10 mm DSV at 25 T (left). After being implemented in the SCH magnet for DC Magnet users, this resistive shim technology will help enable the next generation of NMR magnets proposed to use high-temperature super-conductors to operate at 30T and above