1 / 24

Density-Based Model of Bending Strength for AGR Graphites Irradiated in Oxidising Environments

Density-Based Model of Bending Strength for AGR Graphites Irradiated in Oxidising Environments. Ernie D. Eason Modeling & Computing Services Boulder, Colorado, USA eeason@ix.netcom.com Graham Hall Barry J. Marsden

lyle
Download Presentation

Density-Based Model of Bending Strength for AGR Graphites Irradiated in Oxidising Environments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Density-Based Model of Bending Strength for AGR Graphites Irradiated in Oxidising Environments Ernie D. Eason Modeling & Computing ServicesBoulder, Colorado, USA eeason@ix.netcom.com Graham Hall Barry J. Marsden Nuclear Graphite Research Group, School of Mechanical, Aerospace & Civil Engineering, University of Manchester, UK graham.n.hall@manchester.ac.uk barry.J.marsden@manchester.ac.uk Presented at INGSM-14 Seattle, Washington, USA September 18, 2013

  2. Data Used for Density-Based Strength Models • Trepanned data 1998 - 2010 used for model calibration and validation: • All are 3-point bending strength, measured at Windscale Nuclear Laboratories (WNL) • 1835 points were used for calibration • 203 randomly-selected points were set aside, used to validate the model on data not used for fitting • 2013 models and comparisons are based on trepanned bending strength S, not ratio S/S0

  3. Trepanned Bending Strength Irradiated Density Model • Model form • The coefficients Ci and exponents Ni vary by reactor • The Tirr term is a small correction (+3%, -1%) • Average Tirr = 402.75C over all trepanned data

  4. Advantages of an Irradiated Density Strength Model versus a Weight Loss Strength Model • Simple power function form • Better fit than a model based on weight loss on the same data • Slightly smaller standard error, 3.99 vs. 4.09 MPa • No significant residual error trend in any variable • Much smaller “year effect” than a weight loss model (1/3 as large) • No need to estimate virgin density or make corrections as with weight loss estimates

  5. The “Year Effect”-- Strength Appears to Increase with Trepanning Year 26 MPa 2003 24 MPa 2000 Same reactor, three sets of strength measurements from trepanning campaigns 3 and 6 years apart 29 MPa 2006

  6. The “Year Effect” for Weight Loss versus Density-based Strength Models 1/3 as much Increase Measured Strength Increases Significantly in Newer Data Preliminary Weight Loss Model Preliminary Density-Based Model

  7. Method of Fitting the Density-Based Model • Preliminary model fitted to Strength, S • Final model fitted to log(S) • Distribution of residuals is approximately normal AND approximately log-normal, so either fit is statistically reasonable • Fitting a power law in the logs is common practice • produces a linear least squares fit • minimizes relative error • log(S) fit is practically better – tighter estimates at low S and low irr(expect lower S at long exposure)

  8. Model and Calibration Data Plots

  9. Chauvenet Outliers • Chauvenet outliers are points so far from the model that they should not be observed in a normal or log-normal distribution of data • A few Chauvenet outliers were identified • 2 outliers from preliminary models calibrated to S • 5 additional outliers from the final model calibrated to log(S) • The outliers represent 0.3% of 2038 points

  10. Model and Calibration Data Plots, cont’d

  11. Density-Based Strength Model Quality of Fit • Standard Error Se = 0.05026 measured as log(S) corresponds to 12.3% relative error • Over the range of measured strength in the data set (9 < S ≤ 58 MPa), 12.3% error corresponds to 1.1 to 7.1 MPa • Model vs. measured log(S) shows overall agreement of data and model (next slide) • All residual plots are flat, with non-significant trends (next several slides)

  12. Calibration and Validation Data Sets Calibration Data Validation Data The Validation Data Fit The Model as Well as the Calibration Data

  13. Flat Residual Plots

  14. Flat Residual Plots, continued

  15. The “Year Effect” for Weight Loss versus Density-based Models – Residual Plots Significant Residual Trend No Significant Residual Trend

  16. Flat Residual Plot for Inert-Irradiated Young’s Modulus Ratio Including a function of inert E does not improve the density-based model

  17. Significant Residual Trends if Inert-Irradiated Young’s Modulus is Imposed Including (inert E)0.5 in the density-based model seriously degrades the fit Unconservative (actual S < model S) Conservative (actual S > model S)

  18. Newer Data, Received After Calibration Density-Based Model Calibrated to 1998 – 2010 Data Reasonably Predicts 2011 & 2012 Trepanned Data 2011 & 2012 Data Model Prediction, 1:1 Line Differences Not Significant

  19. Conclusions on the Density-Based Strength Model Fitted to log(Strength) • The density-based model provides a simple, good fit (12.3% relative error) • The density model is better than a weight loss model • Slightly lower standard error on the same data • No significant residual error trends • Much smaller, non-significant “year effect” • No need to estimate virgin density • The density-based bending strength model does not need or benefit from including an inert Young’s modulus term • Including an (inert E)0.5 term in either weight loss or density-based bending strength models seriously degrades the fit • The density-based bending strength model reasonably predicts data not used for fitting, including • Randomly-selected validation set • Newer trepanned data and several other comparison sets

  20. Additional slides follow for answering questions

  21. Additional Comparison Data for Density-Based Strength Models • Installed samples from HNB R4 and HRA R2, irradiated in HPB R3, measured 3-point bending strength • Trepanned data 1996 – 2000, 3-point bending strength measured at Berkeley Technical Centre (BTC) • BFB & DIDO test reactor irradiations under oxidising conditions, measured annealed tensile strength SA

  22. Density-Based Strength Model Compared with Installed Sample Data Not Used for Fitting (solid black symbols) HNB HRA

  23. Density-Based Strength Model and BTC Data Not Used for Fitting The BTC data average 1 MPa below the WNL data and model

  24. Density-Based Strength Model & BFB and DIDO Annealed Data Not Used for Fitting (Coefficient recalibrated for annealed tensile strength)

More Related