An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Replacement for COROS LS-C ?

  2. Starting situation • Spare parts are not available • Invest „los Engineering" ? • Alternative „new control system„ • Confine teeth with automation • Complete new project engineering, there no conversion of project engineering data (e.g. after WinCC) available • Different control concepts • Performance losses possible

  3. The Solution ! • new control system • migration on WINCC • COROS LS-C ME

  4. Replacement for COROS LS-C ? • new control system • migration on WINCC (cemat V5) • COROS LS-C ME

  5. new control system • Exchange and new project engineering of the control station hardware • Exchange and new project engineering of the PLC • New project engineering of all communications and Subcontrols • Coupling of existing inputs/output periphery • Restarting operation of the overall system

  6. Replacement for COROS LS-C ? • New control system • Migration to WINCC (Siemens) • COROS LS-C ME

  7. Engineering-Station control Station expansion Color Graphic Color Graphic COROS Master Server OS - AG SIMATIC S5 155U SIMATIC S7-400 • CPU 948 SIMATIC S5 155U SIMATIC S5 155U • CP143 oder CP1430 Profibus DP • 30 kWorte = 60 kByte R I/O R I/O R I/O R I/O D A D A D A D A Profibus DP Migration on WINCC SIMATIC-suppostion

  8. Migration on WINCC • Exchange and new project engineering of the control station hardware • No costs on the automation side (PLC) for - New project engineering - New start-up - Wiring - Input/output periphery - Re-education of your service personnel • Resembles control philosophy • Minimum plant stop

  9. Which costs a migration on WINCC ? • OS Client RT License per Client • WINCC ca. 6.000 € • OS Server RT License per Server • WINCC, CP1613 ca. 13.000 € • Engineering Station License, 1x • WINCC, CP1613 ca. 17.000 €

  10. Which costs a migration on WINCC ? • Hardware • Network components depending upon • Personal computer depending upon desire • Server computer depending upon desire • Engineering • Engineering expenditure after system size and version, approx.. 1-2 men months • Adjustment Subcontrols

  11. Replacement for COROS LS-C ? • new control system • migration on WINCC • COROS LS-C ME

  12. Example of a configuration COROS LS-C

  13. Example of a configuration COROS LS-C ME

  14. Advantages of LS-C ME (1) • Standard computer applicable • Use of Windows 2000/XP • Performance increase • Use of current standard printers • Integration into existing networks - Employment of modern safeguard methods - Use of net drive assemblies - Use of network printers

  15. Advantages of LS-C ME (2) • Increase of the reliability possible, by - RAID CONTROLLER - high-available servers • Simple data protection • Over network possible • Disaster Recovery, e.g. with Norton Ghost • Remote maintenance, (e.g. pcAnywhere) • Operator station at the same time also for other applications usable • Multi-monitoring possible (not LS-C ME)

  16. Transferred for LS-C ME • LS-C ME is compatible, i.e. no changes - in project engineering or - in the host system necessarily • With necessary an on-line setting did not even transfer from LS-C V5,72 is • Conversion of the disks (5¼ and/or 3½) IRMX format) takes place via third • The old system remains unchanged, i.e. back stairs are at any time possible • Projecting bar remains complete

  17. Conditions for transferred • Starting point LS-C V5.72 - evtl. Upgrade is possible on new platform • Hardware-Plattform • change CP-Cxx to CP-CLAN • change OS-Cxx to Windows 2000 / XP computer • LAN connection make • Software Installation • , is provided the appropriate Scriptfiles converts project engineering if necessary on 5.72 (V7.1)

  18. Restrictions of LS-C ME • Light pen is not supported • Touch screen does not implement at present • Dissolution of diagram reduced, i.e. small differences in picture geometry possible • Process control keyboards must be attached over converters • CP printers must (to be allowed!) as network printers to be installed

  19. Planned extensions for LS-C ME • exportfunction (in to csv-format) for • Measure archive • Annunciation archive • PDO-file archive • OPC server for the access to the measured values of the host (input/output of ranges) • Migration path to WinCC

  20. Simatic Simicro S5 MMC Hostkommunikation Bildaktuali-sierung Meßwert-bearbeitung Meldungs-bearbeitung Prozeß-Datenabbild VDU-Kommunikation CP-Cx CP-Kommunikation CP-Kommunikation Dialoge + Masken Meßwert-Archiv Meldungs-Archiv PDO Daten-haltung Editoren Dialoge + Masken OS-Cx OT-Cx Darstellung Darstellung Software architecture LS-C

  21. Simatic Simicro S5 MMC Hostkommunikation CP-CLAN TCP/IP Host-Kommunikation Bildaktuali-sierung Meßwert-bearbeitung Meldungs-bearbeitung Prozeß-Daten-abbild Dialoge + Masken Dialoge + Masken Meßwert-Archiv Meldungs-Archiv PDO Daten-haltung Editoren OS-C ME OS-C ME Darstellung Darstellung Software architecture LS-C ME

  22. Simatic Simicro S5 MMC Hostkommunikation CP-CLAN TCP/IP Prozeß-Datenabbild Host-Kommunikation OPC-Server B+B-System z.B.WinCC Migration path to WinCC

  23. What costs transferred to LS-C ME? • Licencens • OS-C ME Masterlizenz € 13.000,- • OS-C ME Slavelizenz € 9.000,- • Hardware • CP-C ME € 6.000,- • netware component € 500,- • Industrial PC computer P4 € 2.000,- • 18“ Flat screen € 500,- • Engineering • Engineering expenditure after system size and version, approx.. 2-3 men days

  24. When you can transfer ? • Delivery release V 7.x April 2003 • all function are avaliable and testet

  25. Which use does COROS LS-C ME have ? • Solution of the spare part problems by standard hardware • 10 years supply and to support warranty • Simple administration by operation system (WIN2000/XP) up-to-date

  26. with further question ? SAPI Software GmbH D-67346 SPEYER Fon: +49 (0) 6232 6018 0 Fax: +49 (0) 6232 6018 50 Email: INFO@SAPI.de