An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design and Development of a Thermoelectric Beverage Cooler By: Brandon Carpenter Andrew Johnston Tim Taylor Faculty Advisor: Dr. QuamrulMazumder University of Michigan - Flint

  2. Objective • Refrigerator designed for cooling large multiple items • Inefficient if only a single item is to be cooled • Due to size is non-portable • Technology requires coolant, compressor, and cumbersome tubing

  3. Objective • Apply concept of refrigerator to a small scale device • Solid-state, eliminate need for coolants • Portability; can be taken wherever needed • Concentrate cooling onto single object to be cooled, eliminate energy waste in cooling empty space

  4. Objective Turn This Into This

  5. Engineering Approach • Use Peltier thermo cooler to provide cooling • Use tight fitting aluminum sleeve to enhance conductivity • Machine base to match contour of can bottom • Use fans with heat sink to remove heat • Power with drill battery

  6. Preliminary Calculations • Initial goal: to cool a can from 700F to 350F in approximately 5 minutes. • Required Cooling Rate: q= ρ V c q= (1000kg/m3)( 3.54(10-4)m3)( 4.189kJ/kg∙K)( .0533 K/second) This gives a value for q of .079 kW, or 79 Watts.

  7. Further Calculations • Base: ΔT = 16K kAl = .58W/m•K A= .00383m2 dx= .0051m • q = kA q= (.58)(.00383)(3137) q = 6.99W • Sleeve: ΔT = 16K kAl = .58W/m•K L = .108m r1= .0327m r2= .0349m • q = 2πLk q= 2π(.108)(.58) = 95.4W [3] • Total Cooling = 95.4W + 6.99W = 102.4W

  8. Main Components • Peltier Cooler Model TEC1-12709 Rated for 90W/ 139W Max

  9. Notes on Cooler • While a cooler with a higher rated wattage would theoretically be able to remove more heat, it creates more heat due to resistance and requires a much larger heat sink. • In order to remain portable a smaller cooler was needed, affecting cooling time.

  10. Main Components • Sleeve 6061 Aluminum Cut to appropriate length 2.62” Inner Diameter 0.065” Wall Thickness

  11. Main Components • Machined Base 6061 Aluminum Designed to accommodate various cans, as dimensions can differ

  12. Manufacturing / Assembly • Aluminum tubing was cut into appropriate • lengths to make sections • Beverage Compartment • Fan Housing (which was not used) • Wiring Compartment • Battery Compartment

  13. Manufacturing / Assembly • Discs were made to serve as plates between sections and for mounting purposes

  14. Manufacturing / Assembly • Components were assembled using machine screws and adhesives

  15. Manufacturing / Assembly • Insulation was placed around beverage compartment • Thermal paste was applied between thermo cooler, heat sink, top disc, base, and sleeve

  16. Testing Procedure

  17. Testing Procedure • A 12 oz. pop can is filled with water and placed in the beverage compartment • Initial temperature of the water is recorded • Cooler is turned on, and temperature is recorded in two minute intervals • Additionally, the ambient air temperature, starting battery voltage, and final battery voltage are recorded to check for any correlation

  18. Testing Procedure • For each test, the data is entered into an Excel spreadsheet For comparison purposes, a similar test was conducted using a refrigerator

  19. Results Data in graph form

  20. Discussion • Refrigerator – constant 0.317⁰F / min • Cooler - maximum 0.65⁰F / min - average 0.317⁰F / min • In terms of the cooler outperformed the refrigerator • Could only maintain this cooling level for short period due to battery

  21. Conclusion • With available technology idea is not yet practical • Current Peltier coolers are not very efficient, require large heat sinks which hinder portability • Also battery power/size ratio insufficient for portability