An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UPC or APC - Which One to Choose? What is the Meaning of UPC and APC? Whenever a connector is installed on the end of fiber, loss is incurred. Some of this light loss is reflected directly back down the fiber towards the light source that generated it. These back reflections will damage the laser light sources and also disrupt the transmitted signal. To reduce back reflections, we can polish connector ferrules to different finishes. There are four types of connector ferrule polishing style in all. UPC and APC are two types of them. UPC stands for Ultra Physical Contact connector. The current trend is using it in deadlines to allow operators to perform networks tests for example by using an OTDR. APC stands for Angled Physical Contact connector. APC is the most used polishing type nowadays. Click here you can find more information about other types of connectors. Differences between UPC and APC Connector Appearance The main difference between UPC connector and APC connector is the fiber endface. APC connectors have the endface that is polished at an eight degree angle, while UPC connectors are polished with no angle, but UPC connectors have a slight curvature. Color Color is another difference between UPC connector and APC connector, and it is quite obvious. UPC connectors are blue and UPC connectors are green.

  2. Insertion Loss Different polishing styles determine the quality of optical fiber, which results in different performances regarding the connector's insertion loss and return loss. Insertion loss refers to the signal loss caused by the connector or cable. In general, the typical insertion loss of PC, UPC, and APC connectors should be less than 0.3dB. Compared with APC connectors, UPC connectors are usually easier to achieve low insertion loss due to the smaller air gap. Return Loss Return loss, also known as reflection loss, is a parameter representing the signal reflection performance. The end faces of APC connectors are beveled, so the return loss of APC connectors is usually better than UPC connectors. In general, the return loss of the PC fiber cable is -40dB. UPC return loss is higher relative to PC, generally at -55dB (or even higher). APC industry-standard return loss is -65dB. Application APC is more suited for high bandwidth applications and long distance links, such as FTTx, passive optical network (PON) and wavelength division multiplex (WDM), they are more sensitive to return loss. If the return loss requirement is not high, UPC is a better choice. Conclusion Many people may ask which one is better, UPC connector or APC connector? The answer is that it depends on your need, because they have expertise in different places. Baudcom offers a variety of fiber optic patch cords with all types of connectors. For more information about UPC and APC fiber optic connectors, please visit www.baudcom.com.cn.

More Related