1 / 54

TrueZONE™Panels Training Module

To advance this module, click when this icon appears on the slide. TrueZONE™Panels Training Module. Click For Next Slide. What you will learn. Why Zoning? Current Zoning Situation Features and Benefits TrueZONE™ Panels TrueZONE™ Panel Product Family Overview and Wiring Support Materials.

marlon
Download Presentation

TrueZONE™Panels Training Module

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. To advance this module, click when this icon appears on the slide. TrueZONE™Panels Training Module Click For Next Slide

  2. What you will learn • Why Zoning? • Current Zoning Situation • Features and Benefits TrueZONE™ Panels • TrueZONE™ Panel Product Family Overview and Wiring • Support Materials Click For Next Slide

  3. Why Zoning? Click For Next Slide

  4. 2006 American Home Comfort Study 67% of US homeowners are uncomfortable in their homes at certain times of the year. Homeowners want Zoning! Contractor Knowledge and Education is Key Click For Next Slide

  5. Homeowners Need Zoning The #1 complaint from new homeowners after 1 year of living in a new home is uneven temperature in their house. “I just paid $400,000 for my home and it doesn’t heat & cool properly!” Click For Next Slide

  6. Homeowner Benefits • Customer Comfort! • Where you want it when you want it • Comfortable upstairs and downstairs • The convenience of a thermostat in each zone • Energy Savings/Eco-Friendly • Only Heat or Cool the rooms you use Click For Next Slide

  7. Contractor Benefits • Builder/Homebuyer Satisfaction • Improved Profit Margins • Differentiation • Product Easy to Access and Readily Available • Easiest to Install and Operate • Product Quality, Reliability and Performance • Honeywell World Class Support Click For Next Slide

  8. Why Honeywell Zoning? • Brand • A name consumers know & trust • Best in Class • Innovative leader with easiest to install, highest quality systems • Improved Profit Margins • Differentiation • Complete Product Offering • Panels • Dampers • System Kits • Support • Trained Contractor Zoning Specialists • Dedicated Zoning Technical Support Hotline: 1-800-828-8367 Click For Next Slide

  9. Current Zoning Situation Click For Next Slide

  10. Zoning Current Situation • Problem • Current zoning panels are complicated, requiring extra time and labor to install – leading to increased call backs. • Pots, dipswitches and jumpers are difficult to use and can break easily making installation confusing and time consuming. Click For Next Slide

  11. Current Market Call Backs Research shows between 10% - 15% of all industry zoning jobs have a callback resulting in wasted time and money. Click For Next Slide

  12. HZ311 HZ322 HZ432 Far Better Situation - Zoning Made Effortless! TrueZONE Panels Replacing the TZ-4 and EMM Panels Click For Next Slide

  13. Virtually Eliminate Callbacks! Set Jumpers, 7% Thermostat Wiring 19% Set DIPS, 19% Panel Problem, 8% Configure OC, 3% Damper Wiring 11% Equipment Wiring 12% Wiring Transformer, 4% UI Explained, 5% Air Noise, 1% Equipment Problem, 2% Operation Explained, 2% Limit, low or high 1% Damper Operation Wiring TAZ, 2% 5% TrueZONE™ Reduces Callbacks by 87% Click For Next Slide

  14. Features and Benefits TrueZONE™ Panels Click For Next Slide

  15. TrueZONE Key Features • Intuitive Installer Setup — Easy-to-follow, digital display uses real language to guide installer through four simple steps*. • 1) Select equipment type • 2) Select heat/cool stages • 3) Select number of zones • 4) Select stage control Click For Next Slide *HZ432 and HZ322 only

  16. HZ432 & HZ322 Advanced Setup • Advanced Setup is not Usually Necessary • Basic configuration choices default the Advanced Setups for you • But you can use Advanced Setup to tweak these settings • Advanced Setup Configures: • Stage timer (one for 2nd stage, and one for 3rd stage) • Purge Timer (2, 3.5, or 5 minutes) • AutoChangeover Delay (15, 20, 30 minutes) • DATS High limit (110-180) • DATS Low limit (30-60) • Type of Thermostat (Conventional or HP using O or B) • Dual Fuel Balance Temperature (30-50) • And more! Click For Next Slide

  17. TrueZONE Key Features • Standardized Checkout Procedure — Standardizes the checkout process so that every installer checks out in the same way, every time to ensure that all zones are operating correctly before leaving the jobsite. Only one installer needed for checkout. (HZ432 and HZ322 only) Click For Next Slide

  18. TrueZONE Key Features • Robust Push Terminals — Push-in terminal blocks wire in literally half the time compared to screw terminals — with no screwdriver required. Plus, wires lock-in to the terminals for a tight fit. • Common-Sense LEDs — Indicate which zones are calling, what stage they are calling for (heat/cool) and when the emergency heat is on. • Universal Application — TrueZONE panels work with virtually any brand equipment for zone control of conventional, heat pump or dual fuel systems. Click For Next Slide

  19. TrueZONE Key Features • Variable-Speed Fan Control — Reduces blower speed in cooling when one zone is calling. • Discharge Temperature (DATS) Staging — Downstages equipment when discharge air temperature is near the limit. (HZ432 and HZ322) • Advanced Dual-Fuel Operation — Offers dual-fuel changeover based on outdoor temperature and/or thermostat staging. (HZ432 only) Click For Next Slide

  20. Installation Flexibility • Smaller Footprint — Gives installer the ability to mount TrueZONE panels anywhere — on the return duct, studs or wall next to the system. All panels are only eight inches wide. Fits on Returns, 2x4, or wall. Mounting holes in corners for wall mount, and in center for 2X4 mounting. Click For Next Slide

  21. Easy Wire Routing • Clean, Professional Installation — Wire channel allows installer to run wires on the side, top, bottom or backside of the panel and wire anchors help hold wires in place. Run wires in from top, bottom, sides, or behind panel. Wire tie anchors. For neat, secure installation Click For Next Slide

  22. TrueZONE Key Features • Highest Quality in Industry • Electronic Excellence • 100% Surface mount technology • 100% covered electronics • Extreme reliability – even in very hot attics up to 165° • Tested and operated to 220°: melted plastic, but panel still works! • Best In Class Circuit Breaker Protection • Use any size transformer to power many dampers • Each zone is protected by its own circuit breaker - Patented • Panel will continue to run even when one breaker trips • Volt Meter Probe Troubleshooting • Copper plate by each terminal can be used to check voltages Click For Next Slide

  23. HZ311 Overview Click For Next Slide

  24. HZ322 Overview Click For Next Slide

  25. HZ432 Overview Click For Next Slide

  26. Use Any Thermostat to Control Zoning System! Click For Next Slide

  27. TrueZONE™ Panel Product Family Overview and Wiring Click For Next Slide

  28. HZ432 Key Features and Wiring • Compatible with Variable Speed Blowers • Reduces blower speed when 1 zone is calling • Or when 25% or fewer zones are calling when more than 4 zones are controlled • Dual Fuel • Changeover by OT temperature • Or by OT Temperature and Call for 2nd stage heat • Multi-Stage OT Lockout • Connect an OT sensor to panel • When outdoor temp rises above set temp (10°-50°F) • 2nd and 3rd stage heat is locked out on non-dual fuel systems Click For Next Slide

  29. HZ432 Configuration • Quick Setup in real language reduces install time! • No dips, pots or jumpers! • Intuitive setup with clear display • Intelligent…it configures itself based on your selections • Most setups require only 5 menu choices! • Advanced configuration available for advanced control Click For Next Slide

  30. HZ432 Other Features • DATS Limits • 110-180° F in heat • 30-60° F in cool • DATS Multi-Stage Inhibit • Locks out 2nd and 3rd stage when close to high or low DATS limits • Powers Many Dampers • Size the transformer for dampers and panel (10 VA) • Control up to 5 ARD or ZD per zone • Or up to 26 RRD per panel! Click For Next Slide

  31. HZ432 Other Features • Auto-changeover Delay • Can be set to 15, 20, or 30 minutes • Purge Configuration • The purge time can be configured to be 2, 3.5, or 5 minutes • Multi Stage Control • The panel can control multi-stage conventional heat pump and conventional equipment by: • A multi-stage thermostat • Percentage of zones calling • Timer Click For Next Slide

  32. HZ432 Wiring Wire Thermostat and dampers to each zone: Click For Next Slide

  33. TrueZONE Key Features • Intuitive Installer Setup — Easy-to-follow, digital display uses real language to guide installer through four simple steps*. • 1) Select equipment type • 2) Select heat/cool stages • 3) Select number of zones • 4) Select stage control *HZ432 and HZ322 only Click For Next Slide

  34. TrueZONE Key Features • Standardized Checkout Procedure — Standardizes the checkout process so that every installer checks out in the same way,every time to ensure that all zones are operating correctly before leaving the jobsite. Only one installer needed for checkout. (HZ432 and HZ322 only) Click For Next Slide

  35. HZ322 Key Features and Wiring Click For Next Slide

  36. HZ322 Key Features and Wiring • Controls Conventional and Heat Pump Equipment • Up to 2 Stages Heat, 2 Stages Cool • Up to 3-Zone Panel • Quick Setup with intuitive menu on display • Intelligent…it configures itself based on your selections! • Compatible with Variable Speed Blowers reduces blower speed when 1 zone is calling Click For Next Slide

  37. HZ322 Other Features DATS Limits 110-180° F in heat 30-60° F in cool DATS Multi-Stage Inhibit Locks out 2nd and 3rd stage when close to high or low DATS limits Powers Many Dampers Size the transformer for dampers and panel (10 VA) Control up to 5 ARD or ZD per zone Or up to 26 RRD per panel! Click For Next Slide

  38. HZ322 Other Features: Same as HZ432 Auto-changeover Delay Can be set to 15, 20, or 30 minutes Purge Configuration The purge time can be configured to be 2, 3.5, or 5 minutes Multi Stage Control The panel can control multi-stage conventional heat pump and conventional equipment by: A multi-stage thermostat Percentage of zones calling Timer Click For Next Slide

  39. HZ322 Wiring Wires Just Like the HZ432, but without W3 Click For Next Slide

  40. HZ311 Key Features and Wiring Click For Next Slide

  41. HZ311 Key Features and Wiring • Controls Conventional Equipment • Up to 1 Stage Heat, 1 Stage Cool • Up to 3-Zone Panel • No configuration at all – Very, Very Easy! • Quick Hookup • Just strip the wire and push in • Great for New Construction • Small size fits anywhere • Perfect for attic installations…up to 165°F! Click For Next Slide

  42. HZ311 Key Features and Wiring • Powers Many Dampers • Size the transformer to power dampers and panel (6.25 VA) • Control up to 5 ARD or ZD per zone • Or up to 26 RRD per panel Controls Conventional Equipment • Up to 1 Stage Heat, 1 Stage Cool • Compatible with Variable Speed Blowers • Reduces blower speed when 1 zone is calling Click For Next Slide

  43. HZ311 Wiring: Wire Thermostats and Dampers Wire Thermostats and Dampers: Click For Next Slide

  44. HZ311 Wiring Wire Equipment Click For Next Slide

  45. Kits • Comes with… • Panel • Transformer • Discharge Air Temperature Sensor • Just add… • Zone Dampers • Bypass Dampers Click For Next Slide

  46. Need Help? Warranty Honeywell Zoning products carry a 5-year limited warranty Technical Support 1(800)-TAT-TEMP1 800-828-8367 M-F 7:00-4:00 CST On The Web http://customer.honeywell.com www.forwardthinking.honeywell.com Click For Next Slide

  47. TrueZONE™Support Materials Click For Next Slide

  48. TrueZONE Interactive Demos • Get more marketing, technical and install information and interactive demos online at www.forwardthinking.honeywell.com. • Use as a part of your overall training package with customers, sales and counter staff. Click For Next Slide

  49. TrueZONE™ Panels Knowledge Test • Now that you completed this training module, take the short quiz to test your knowledge.

  50. Test 1. When asked, what % of US homeowners are uncomfortable in their homes at certain times of the year. a. 20% b. 56% c. 67% d. 85% 2. What is a homeowner benefit of zoning? a. Uneven temperatures in the home b. Only heat and cool the rooms they use c. Easy to Install and Operate d. Honeywell is a brand Homeowners trust

More Related