1 / 17

For most efficient engineering

For most efficient engineering. nxt STUDIO. nxt LIB. nxt RT61499 F. nxt HMI. Products for efficient engineering. nxtLIB. CAT libraries Ready-to-use SW objects. of distributed and integrated systems. nxtSTUDIO. Engineering Studio. I/O connection Deployment Documentation Debugging

marnie
Download Presentation

For most efficient engineering

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Formostefficientengineering nxtSTUDIO nxtLIB nxtRT61499 F nxtHMI

  2. Products for efficient engineering nxtLIB CAT libraries Ready-to-useSW objects of distributed and integrated systems nxtSTUDIO Engineering Studio I/O connection Deployment Documentation Debugging Test/Simulation etc. Editor Controllogic Editor Visualisation nxtSCADA SCADA Runtimesystem Base library nxtHMI HMI Runtimesystem nxtRT61499 IEC61499 Runtimesystem

  3. The MOST EFFICIENT ENGINEERING TOOL for the automation ofdistributed and integrated systems Engineering Studio /nxtSTUDIO nxtSTUDIOspecifiactions Engineering of … with a singletool IEC CAT NOL … Control logic in a distributed system … HMI visualisation … SCADA visualisation … Documentation … Test & Simulation … own software objects (CATs) … own libraries X XX X X X X X XX X XX X X IEC = Studio for just control logic engineering CAT = Studio for engineering with ready-to-use software-objects (libraries) NOL = Studio same as above but with possiblity to create own software objects (full version)

  4. Engineering Studio /nxtSTUDIO Workspace State of the art Editor Customizable workspace Storing of different layouts All project data at a glance Topology Project overview View on technological coherence

  5. Engineering Studio /nxtSTUDIO • Editor: Control logic • Logic of the whole system • Distribution of control logic to several controllers • Automatically build cross-communication • Program data in XML • Structured Text Editor • Adapter and attribut support • Editor : Visualisation • Visual Studio compatible • Symbol & faceplate Editor • Autom. Built Navigation-Menu • Programmable in C# • HMI export to USB-Stick • Multi-Topology • Multi-Screens • Multi-Resolution

  6. Engineering Studio /nxtSTUDIO • Hardware Abstraction • Hardware as software-objects • Independent from application • Commissioning, diagnostic, simulation via HMI • Simple I/O connection • Runtime configuration tool • configurators for field busses • I/O Connection • Simple Drag & Drop • Listing of available I/Os • Prevents wrong connections • Structured view of all I/Os Temp.fv / AI.SymName0

  7. Engineering Studio /nxtSTUDIO • Mapping / Distribution • Simple Drag & Drop • Automatically built cross communication in-between controllers • Automatically mapping/distribution of control logic at mass-engineering Documentation Automatically built documentation (Docbookoder WYSIWYG) Customized layouts Help content as HTML export Diagrams with cross referencing

  8. Engineering Studio /nxtSTUDIO • Testcontainer: Control • Simulation of function blocks • Breakpoints • Force, Watch, Watch Trend • Context sensitive switching of debugger • Testcontainer : Visu • Simulation of visual functions • Status can be exported and edited

  9. Engineering Studio /nxtSTUDIO Focus on Select Active Zoom Cross Reference / printpage XML view

  10. Engineering Studio /nxtSTUDIO Intellisense Cross Referencing ECC Watch

  11. Library /nxtLIB Ready-to-use software-objects (CAT) for quick and save engineering BUILDING Room control Heating Cooling Ventilation Access control Lighting Sun blind Energy supply Timer switch Calender Weather clock Fire dampers Movable walls … PROCESS PID controller Ramp Sequencer Analog processing Miscellaneous Motors Miscellaneous Valves Limit schwitch Alarm processing Digital processing Technological objects Schrittketten objects Mathematic FBs … HARDWARE Advantech ADAM Beckhoff CX … Series Siemens Microbox Siemens EC31 Wago … --------------------------- KNX/EIB EtherCAT Profibus DALI …

  12. Library /nxtLIB CAT – Control logic Library as Setup File incl. version control Creation of binary Libraries Connection to visualisation CAT in CAT structures Definition of I/O points • CAT – Visualisation • Choice of animated symbols by Drag & Drop • Automatic data connectin to control objects • User hierarchy for parameterization, …

  13. Library /nxtLIB CAT – Control logic Composite Consollidated hierarchical objects levels Encapsulation of compelxity Single-Line-Engineering The simpliest way of engineering A single line connection in-between FBs or CATs Fault prevention through connection check

  14. IEC 61499 /nxtRT61499 F Control Runtime for distributed systems with automatic cross-communication Operation systems: RTTarget, eCos, Linux, Win32, VxWorks Platforms: Advantech ADAM, Beckhoff CX1… Serie, Wago, Siemens Microbox, Siemes EC31, etc. Features: Just-in-Time backend compiler IEC norm compliant Class 2 implementation Event orientated time stamping within the controllers Ring buffer for short time archiving within the controllers UDP based Ethernet cross communication Runtime configuration support OPC-UA DA Slave (Server) SNTP Client SNMP Runtime status reporting (for eCos) Hardware watch-dog Realtime clock support IEC Online Editor: Force I/Os, Watch Service, Trigger/Block Events

  15. nxtHMI / SCADA Runtime for Multi-Client Visualisation without need of additional server Operationsystems: Windows.NET Features: .NET 3.5 Win32 runtime HMI clients connect automatically to all necessary controllers Several HMI clients can be simultanously operated No additional HMI / SCADA servers needed Dynamically adaptable resolution (Zoom) Automatically created alarm lists Simple langauge switching Integriertated Log Viewer Archive Link Redundant operation possible Support of PostgreSQL, Winstör, usw. databases Konfiguration management of controllers Data recording (Werte, Alarme, Journale)

  16. … mostefficient Engineering A single engineering tool for all automation tasks reale devices represented as software objects Distribute control logic by simple Drag & Drop Hardware independent engineering Virtualisation of hardware Automatically established cross communication Automatically established communication beetwen controllers and visualisation clients No SCADA / HMI server needed No interfaces to be programmed System modelling instead of device programming Pathbreakinguseability

  17. EFFICIENT ENGINEERING of distributed systems Save TIME and MONEY with clever solutions