560 likes | 681 Views
Experiments to detect q 13. M.Apollonio Universita’ di Trieste e INFN. Layout of the talk. q 13 and motivations to its measurement Chooz limit Appearance and disappearance experiments Accelerators (A) Nuclear Reactors (R) (A) Approved projects (Phase I) Phase II Phase III (R)
E N D
Experiments to detect q13 M.Apollonio Universita’ di Trieste e INFN IFAE 2004, Torino
Layout of the talk • q13 and motivations to its measurement • Chooz limit • Appearance and disappearance experiments • Accelerators (A) • Nuclear Reactors (R) • (A) • Approved projects (Phase I) • Phase II • Phase III • (R) • Double-Chooz and similar IFAE 2004, Torino
q13 • Scenario: MiniBoone disfavouring LSND • “standard picture” • 2 Dm2ij (Dm212, Dm223) indipendent • 3 mixing angles (q12, q23, q13) • 1 CP phase • Mixing Matrix PMNS • 1-2 solar mixing • 2-3 atmospheric mixing • 1-3 o e3 mixing: q13 describes oscillations ne at the atmospheric frequency • dCP introduces CP violation effects Current experimental results: • Dm223 ~ 2x10-3 eV2 • Dm212 ~ 7x10-5 eV2 • Dm223 >>Dm212 • q12~35o • q23~45o IFAE 2004, Torino
Why measuring q13? • The least known among the parameters in PMNS • Coupled to eid (Ue3) • q13>0would allow to access d • CP violation in the lepton sector IFAE 2004, Torino
What do we know about q13 today? • q13 must be small (maybe null) • The best limit up to date comes from the reactor experiment CHOOZ: • q13 < 10o-17o • (1.3x10-3<Dm232<3x10-3) [J.Bouchez, NO-VE 2003] [CHOOZ coll., Eur.Phys.J.C27(2003),331-374] IFAE 2004, Torino
3 families scenario:appearance experiments Accelerators NB: P sensitive to d (correlated with q13) • a should be considered • sign(Dm213) is present in A [P.Migliozzi, F.Terranova arXiv:hep-ph/0302274] IFAE 2004, Torino
Accelerators • general concept: conventional beam • Broad band (BBB) • Narrow band (NBB) • Super Beam (SB) • Off-Axis Beam (OA) • b-Beam (bB) • Neutrino Factory (NF) IFAE 2004, Torino
Main backgrounds: • Initial ne contamination in the beam • p0 production (NC) • Near/Far detection (A) General concept Production & focusing oscillation decay (had+m stop) target detection (m,e,t) p nm ne p,K nm m- e- CC nm(>99%) ne nm e- m- ne(<1%) IFAE 2004, Torino
(A)-SB • It is a conventional proton beam whose power is of the order of MW • Produces nm (nm) • Proton-driver: technically feasible • PB: target • Sol.: R&D Proposed rotating tantalum target ring IFAE 2004, Torino
q Decay Pipe Horns Target (A)-OA • Detector laying out of the main beam axis • Kinematics n beam energy almost independent from Ep • Monochromatic suppresses the high energy tails • You pay it in terms of flux • Examples: En at 2 different energy scales for Ep at several OA angles IFAE 2004, Torino
(A)b-Beams[P.Zucchelli, Phys.Lett. B532:166,2002] • Original solution: radioactive ions with short lifetime • acceleration • storage • decay • Es.: b- (6He) ne, b+ (18Ne) ne IFAE 2004, Torino
(A)-NF IFAE 2004, Torino
Experiment Power (MW) E (GeV) L (km) detector Sens to q13 Starting date MINOS 0.4 3 730 Calorimeter 5o 2005 Phase I: use an existing facility and approved projects (q13>5o) OPERA 0.17 20 732 Emulsion 7o 2006 Phase I ICARUS 0.17 20 732 L-Ar 5o 2006 NuMI-OA 0.4 2 700/900 Fine grained calorimeter[20kT] 2.5o 2008 ? Phase II: go for 1st generation of Super-Beams (q13>2.5o) Phase II T2K (OA) 0.8 0.7 295 WC (SuperK) [20kT] 2.3o 2009 T2K-II (OA) 4.0 0.7 295 WC (HyperK) [500kT] 1o 2020 ? Phase III: 2nd generation of Super-Beams (q13>1o) [Phase IV: Neutrino Factories see relevant talk] Phase III SPL-SB 4.0 0.27 130 WC/L-Ar [500kT] 1o ~2015 b-Beam 0.2 0.3-0.6 130 WC/L-Ar [500kT] 0.5o 2018 ? (A) Experiments[J.Bouchez, NO-VE 2003] IFAE 2004, Torino
(A) Experiments (cont’d) • Requirements for Super-Beams (nmne appearance case) • Beam side: • Low ne contamination • Good knowledge of ne/nm • Good understanding of the beam (near to far) • Detector side: • Good e- efficiency • Good p0 rejection • Good understanding of bkg IFAE 2004, Torino
~1 Which energy? • Low or high? • Focalisation of neutrinos ~g2~E2 • Solid angle factor @ L ~1/g2~1/E2 • s(n) ~g~E • p flux ~1/g~1/E • The 0th order approximation cannot help that much in the choice • Other considerations mandatory IFAE 2004, Torino
WC technique gives a good p0 (NC) vs e- separation (2-ring vs 1-ring) Less ne (below K threshold) Fermi momentum poor E resolution No matter effects Better use fine grained detectors or L-Ar TPC Need good p0 rejection More ne bkg Better resolution in E Matter effects can arise sign(Dm213) Low (E<1GeV) or High (E>1GeV) ?[choice related to bkg considered] intrinsic ne contamination and p0 mimicking e- caveat: stay below t threshold IFAE 2004, Torino
Underground or not? • In principle not: just a matter of choosing the right (low) duty cycle [phase II, 20 kton] • BUT it is a must if your detector is “multi-purpose” (e.g. searching for other effects like proton decay) [phase III, 500 kton] IFAE 2004, Torino
Near/Far • Best way to determine ne bkg: measure it at a near location (before oscillation) • Try to ensure equality of conditions between near and far detectors: i.e. same beam, same target nuclei (cross sections and p0 production do depend on nuclei) • Near detector sufficiently far from the source point-like assumption (~ 2 km) • If you go closer then the source is not point-like anymore • Near detector able to understand the different n interactions (QE/non-QE) • Ideally TWO near detectors (~300 m, ~2 km): • One giving a clear clue about n interactions • The other as much as identical to the FAR detector IFAE 2004, Torino
Beam Near(~2km) Far(700km) N F Beam V-Near(300m) Near(~2km) Far(700km) N1 VN F N2 Near/Far (cont’d): strategies for beam understanding • Cheap solution: • N sees a point-like source • F and N use the same detection technique (1/L2 law) • Good for discovery though it does not allow a precise measurement of q13 • “Pricey” solution: • VN N1: similar detection techniques allowing beam understanding • N1 N2: different in s(n) and detector performances can be compared • F and N2 using the same detection technique • Should be optimal for high statistics phase III where you want to reduce systematics (less dramatic for phase II) IFAE 2004, Torino
Time to have a look at some projects … IFAE 2004, Torino
Icarus, Opera IFAE 2004, Torino
full mixing, 5 years run @ 6.76 ´ 1019 pot/year CNGS • Tuned to reach max sensitivity to nt appearance (off-peak) E > Ethre(t)~17 GeV DCNGS~O(10-1) D2 ~ O(10-2) Suppression factor NB: • High cross sections s(nt-CC), s(ne-CC) • High granularity (and detection of te processes): high BKG suppression (NC(p0), nmntt(e)X) • They open a window to q13 IFAE 2004, Torino
Ai~O(1), ACNGS ~ 1.6 |1-A|D<<1 sin2[(1-A)D]/(1-A)2 ~ D2 O1 O3 O2 O3 [P.Migliozzi, NO-VE 2003] O1 and O3 leading Relative importance of the terms in P: case OFF-PEAK:D=p/2 Effect (d-q13) O3 Sign(Dm213) Deterioration effect from q13 ~ 3o IFAE 2004, Torino
PMT Electric Field Ionizing Track UV Light Drifting e- in LAr E1 wire pitch Induction Plane I E2 d Induction Plane II Amplifier E3 d Collection Plane Icarus:Lar-TPC • T~89K, E~.5 kV/cm • tracking, dE/dX, e.m. + had. calorimetry • e/g id // e/p separation • sE/E~13%/sqrt(E) (e.m.) • sE/E~30%/sqrt(E) (had) • Conceived to detect events with t production allows detection of e and therfore the study of channel nmnt • Being built @ LNGS • T600 • 2xT1200 T3000 IFAE 2004, Torino
@ Dm223 = 2.5 x 10-3 C.Montanari-LNGS, 22-marzo-2004 Icarus: expected results for q13 IFAE 2004, Torino
Opera: emulsions + m-spectrometer • Direct observation of the decay products fromt (CC) • High granularity: ~ mm (track separation) • sE/E ~ 20%/sqrt(E) (e.m.) IFAE 2004, Torino
Opera: expected results for q13 2.5x10-3 eV2 0.06 7° IFAE 2004, Torino
CNGS (cont’d) CNGS • Sensitivity to q13 (sign(Dm2)&d effects): sin22q13 5 yrs 0.04 [P.Migliozzi, F.Terranova arXiv:hep-ph/0302274] bkg 10% 0.03 0.02 bkg 5% bkg 2% 0.01 yrs 1 10 100 IFAE 2004, Torino
800 CC νμ / year Eπ vs. Eν 2200 CC νμ / year OA1° 50 kton Water Cherenkov 0.0゜ OA2° 1.0゜ OA3° 1.5゜ 2.0゜ 3.0゜ 5.0゜ Max. osc. energy for 3×10-3eV2 T2K [I/II] • OA: q~2o, JHF-PS(50 GeV p) SK[I] HK[II] • Maximize the potential discovery (on-peak) d,q13,sign(Dm132) • L~295 km, <E>~0.76GeV on peak • |A|~5x10-2 matter effects negligible • Phase I: use SK detector (20 kton) • Phase II: go for a more ambitious device HK (500 kton) IFAE 2004, Torino
p p Muon detector n Water Cherenkov detector Fine grained scintillater detector 8m 0m 140m 280m 2 km 295 km ν μ ν ν beam 8m 15.2m 5m Total mass : 1000ton Fid. Mass : 100ton IFAE 2004, Torino
OAB (2degree) nm Signal for non-zero θ13 in JHF-SK (νμ→νe) BG (NC π0 ….) 0.2% m-decay ne SK-90%CL allowed K-decay SuperKamiokande • Water Cerenkov detector • Sub-GeV good p0/el. separation • q13: 2.5o sensitivity after 5 yrs of data taking T. Kajita, Fermilab – May 2003 IFAE 2004, Torino
HyperKamiokande • Goals: • Improve q13 sensitivity • Go for CP violation measurement IFAE 2004, Torino
T2K-I vs CNGS • Sensitivity to q13 as a function of d • T2K: O2 even in D • CNGS: O3 odd in D IFAE 2004, Torino
CNGS T2K-I 0.05 sin2q13 5 yrs 0.04 bkg 10% 0.03 T2K-II: 1yr! 0.02 bkg 5% bkg 2% 0.01 yrs 1 10 100 T2K I/II vs CNGS • Sensitivity to q13: IFAE 2004, Torino
Minos • L/E tuned to the first MAX at the atmospheric scale (~730km/3GeV) • Magnetized (1.5 T) calorimeter: 8m octagonal steel (5.4 kton) & scintillator (484 planes) • 23%/sqrt(E) (e.m.) • 55%/sqrt(E) (had.) • Taking cosmics • GOALS: • Demonstrate oscillation behavior • Precise measurement of oscillation parameters • Precise Determination of Flavor Participation • Number of CC ne events far/near: Sensitive to nm - ne oscillation down to about 2%. Discovery/first measurement of Ue3? IFAE 2004, Torino
Minos (cont’d) Sensitivity to q13 MINOS 3sdiscovery limits Dm2 = 0.0025 eV2 IFAE 2004, Torino
NuMI-OA • OA: q~0.7o • L~712 km, <E>~2.2 GeV on peak • |A|~0.2 matter effects NOT negligible sensitivity to sign(Dm213) IFAE 2004, Torino
Ai~O(1), AJPARC ~ 0 O1 and O2 leading Relative importance of terms in P: caseON-PEAK:D~p/2 O1 O2 O3 Ai~O(1) Effect (d-q13) O4 Deterioration effect from q13 ~ 3o IFAE 2004, Torino
OPERA alone 5y HI beam /OPERA alone (A) sensitivity to q13 (90% C.L.) a=3x10-2 Ignorance on d phase Ignorance on sign(Dm2) Minos CNGS as a function of a Numi-OA [P.Migliozzi, F.Terranova arXiv:hep-ph/0302274] T2K-I sin2(2q13) IFAE 2004, Torino 0.001 0.01 0.1
Dm2>0 Dm2<0 q13 at (A) • Measurement made difficult by matter effects and CP violation • Sensitivity to q13 strongly depends on d • Synergies among different experiments could help • Ex.: sens. to q13 in T2K + Numi-OA: start T2K in n-mode and Numi-OA in n-mode IFAE 2004, Torino
q13=10° q13=5° • If q13>7o then: indication of appearance at 90% C.L. • Ex1: q13=10o • CNGS: 3 yrs of data taking (T2K-I start), Dm2<>0 • 8 yrs CNGS d.t. + 5 yrs T2K d.t. • Ex2: q13=5o IFAE 2004, Torino
disappearance exp.: Reactors • Reactors: P NOT sensitive to d can do a pure measurement of q13 • Tipical reaction: ne+p e++n • Detection: “prompt” signal from positron (1) + delayed capture of n on Gd (p) (2) [a la Chooz] n ne (2) [F.Dalnoki-Veress, La thuile 2004] e+ (1) IFAE 2004, Torino
10 Chooz νe+p→n+e+ Cross section (~10-42 cm2) Spectrum ne (10-8 /s MeV GWth) 5 Observed spectrum (interactions/MeV ton day) 0 IFAE 2004, Torino
P(nene) q13: amplitude A1=A1(D): atmospheric modulation A2: solar modulation km P(nene) [F.Dalnoki-Veress, La thuile 2004] RI 400 t GW y RII 8000 t GW y [Huber at al., hep-ph/0303232] IFAE 2004, Torino
Chooz: an example of reactor experiment • Relied on • calculation of ne flux from the two reactor cores • computation of the active mass of the target • evaluation of the absolute efficiency • knowledge of ne cross section • Systematics kept at 2.8% finally limited the experimental result IFAE 2004, Torino
The key for a successful new reactor experiment (measuring q13) is reducing the systematics (<1%) and reach enough statistics (<0.5%) • This can be achieved by using a pair of “identical” detectors (near/far technique) • Some ideas are being pursued: • A case: Double Chooz • CAVEAT-1: you never have 2 identical detectors! • Different bkg (and dead times) • S/N different • CAVEAT-2:energy scale and relative non-linearities to be held into account IFAE 2004, Torino
strategies • Faster: • Use existing facilities/places with proper “refurbishing” • Try to get some result before or at the same time as LBL exp’s (e.g. T2K-I, Numi-OA) • Reactors complementarity: • No need to go faster: try instead to perform a highly precise measurement • Build new brand detectors (sophisticated too: e.g. with movable baselines) • You pay it with a later start IFAE 2004, Torino
from CHOOZ to double-CHOOZ 4 • Detector Basics: 2 identical detectors (12.6 m3) at • 150 m • 1050 m • Gd (0.1%) loaded LS • ~ 10 ton • LS buffer • Non-scintillating buffer • VETO 3 2 H.deKerret, NO-VE 2003 1 K.Anderson et al., arXiv:hep-ex/0402041 v1 26 Feb 2004 IFAE 2004, Torino
From CHOOZ to Double-CHOOZ Mainly canceled using the near/far technique Relative error: srel~0.6% [F.Dalnoki-Veress, La thuile 2004/H.De Kerret, NO-VE 2003] ssist~1% Using the same LS/LS+Gd should help a lot to improve these systematics IFAE 2004, Torino
from CHOOZ to double-CHOOZ • Important: reduce the muon flux main cause of correlated background! • Also present the accidental background from natural radioactivity LS buffer + veto • BKG can be measured when (if) reactor is OFF IFAE 2004, Torino