1 / 10

Exercises

Exercises. Example 1: Create a distribution board with…. Degree of protection: IP 31 Main busbar: no busbar Cable connection: from bottom Dimensions (WxHxD): 800 x 2000 x 600 mm Plinth: no Internal partitions: Form 1 1 no. Section for frequency inverter. Width: 800 mm,

mayes
Download Presentation

Exercises

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Exercises Moeller GmbH xEnergy - Page 1

  2. Example 1: Create a distribution board with… Degree of protection: IP 31 Main busbar: no busbar Cable connection: from bottom Dimensions (WxHxD): 800 x 2000 x 600 mm Plinth: no Internal partitions: Form 1 1 no. Section for frequency inverter. Width: 800 mm, with section high mounting plate. Moeller GmbH xEnergy - Page2

  3. Example 2: Create a distribution board with… Degree of protection: IP 31 Netform: TN-S Cable connection: from bottom Dimensions (WxHxD): ? x 2000 x 600 mm Plinth: no Internal partitions: Form 4 Switchgear: 1 no. ACB 3-pole, fixed mounted 3200 A 1 no. MCCB, 3-pole, fixed mounted 800 A 1 no. MCCB, 3-pole, withdrawable 1600 A 1 no. Section for frequency inverter. Width: 800 mm, with section high mounting plate. Moeller GmbH xEnergy - Page3

  4. Example 2: possible front-view Moeller GmbH xEnergy - Page4

  5. Example 2: part list with xEnergy standard line Moeller GmbH xEnergy - Page5

  6. Example 2: Questions • „Our customer is not satisfied with the size of cable connection area for the • 1600 A NZM4 breaker.“ • - What can we do? • - How many ordering types do we have to change? • „Our customer wants now 800 mm deep sections.“ • - Is it possible? How? • „Now the NZM4 should be with remote operation.“ • - Is it possible? How? • „The IZM should be withdrawable.“ • - Is it possible? • - How many ordering types do we have to change? • Change section width to 600 mm. • Only one: XSNW0643 Yes, but not with standard line. Go to catalogue. - Yes with fixed mounted NZM4. No change. - Also yes with withdrawable NZM4, but not with standard line. Go to catalogue. Yes. No changes. Moeller GmbH xEnergy - Page6

  7. Example 3: Create a distribution board with… Degree of protection: IP 55 Netform: TN-S Cable connection: from bottom Dimensions (WxHxD): ? x 2000 x 600 mm Plinth: 100 mm Internal partitions: Form 4 Switchgear: 1 no. ACB 3-pole, withdrawable 1600 A 12 nos. MCCB, 3-pole, fixed mounted up to 125 A 8 nos. MCCB, 3-pole, fixed mounted 160 A 4 nos. MCCB, 3-pole, fixed mounted 200 A 2 nos. MCCB, 3-pole, fixed mounted 400 A 2 nos. MCB, 3P+N 16 A Moeller GmbH xEnergy - Page7

  8. Example 3: possible front-view Moeller GmbH xEnergy - Page8

  9. Example 3: part list with xEnergy standard line Moeller GmbH xEnergy - Page9

  10. Example 4: possible front-view Moeller GmbH xEnergy - Page10

More Related