8. WELD EQUIPMENT SCREEN PRESS MENU, SETUP, F1-TYPE, WELD EQPT. THIS SCREEN DISPLAYS DETAILS OF WELD PROCESS SELECTED IN PRIOR SCREEN(EXAMPLE SHOWS PROCESS 1). IT'S ALSO USED TO SETUP A NEW PROCESS. SELECTED PROCESS DETAILS:.

mayes
Download Presentation

THIS SCREEN DISPLAYS DETAILS OF WELD PROCESS SELECTED IN PRIOR SCREEN(EXAMPLE SHOWS PROCESS 1).

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 8 WELD EQUIPMENT SCREEN PRESS MENU, SETUP, F1-TYPE, WELD EQPT. THIS SCREEN DISPLAYS DETAILS OF WELD PROCESS SELECTED IN PRIOR SCREEN(EXAMPLE SHOWS PROCESS 1). IT'S ALSO USED TO SETUP A NEW PROCESS. SELECTED PROCESS DETAILS: SETUP\Weld\Equip \\\\\\\\\\\JOINT\\10\% 1/17 Welder:Lincoln Electric PowerWave+ArcLnk 1 Process: 1 Wire diameter: [ ] Gas mixture: [ ] Description: [ ] 2 SEARCH for process = GMAW ? YES 3 SEARCH for pulse = NO ? YES 4 SEARCH for wire = Steel ? YES [ TYPE ] SEARCH HELP A YES HERE LIMITS THE SEARCH TO PROCESSES HAVING THESE ITEMS F3 FOR SETTING SEARCH CRITERIA FOR A NEW PROCESS. THE ROBOT SEARCHES THE PW MEMORY FOR PROCESSES WHICH HAVE ALL THE DESIRED ITEMS: 2. PROCESS- GMAW, FCAW: F4-CHOICE 3. PULSE- YES OR NO: F-KEYS YES/NO 4. WIRE- STEEL, ALUM.: F4-CHOICE AFTER 3 LINES ARE SET, PRESS F3-SEARCH. ROBOT SEARCHES PW MEMORY FOR ALL MATCHES TO CRITERIA, THEN DISPLAYS THE MATCHES

  2. 9 SEARCH RESULTS SCREEN THE SEARCH RESULTS ARE NOW DISPLAYED, AS A RESULT OF PRESSING THE F3-SEARCH KEY IN THE PREVIOUS SCREEN. THE VARIOUS MATCHES ARE NUMBERED THIS NOTES THAT THE CURSOR IS ON LINE 1 OF 17 TOTAL MATCHES FOUND. SETUP\Eq\Search\\\\\\ JOINT\\10\% 1/17 PROCESS PULSE WIRE MATERIAL GMAW NO Steel # WIRE DIA DESCRIPTION 1 \10 .035 in [GMAW Steel ] [CV CO2 ] [CO2 ] 2 11 .035 in [GMAW Steel ] [CV ArMix ] [Argon Blends ] [ TYPE ] SELECT HELP MATCH NUMBER PROCESS DETAILS OF EACH MODE PW MODE / MEMORY NUMBER F2 PRESS F2-SELECT TO LOCK IN THE DESIRED MATCH. THE PREVIOUS WELD EQPT SCREEN WILL APPEAR NEXT, DISPLAYING THE PROCESS.

  3. 8 WELD EQUIPMENT SCREEN PRESS MENU, SETUP, F1-TYPE, WELD EQPT. LINE 1 AND ITS BRACKETED AREAS ARE NOW FILLED IN WITH THE PROCESS DETAILS PREVIOUSLY SELECTED. SETUP\Weld\Equip \\\\\\\\\\\JOINT\\10\% 1/17 Welder:Lincoln Electric PowerWave+ArcLnk 1 Process: 1 GMAW Steel # \21 Wire diameter: [ .045 in] Gas mixture: [Ar CO2 ] Description: [CV ArMix ] 2 SEARCH for process = GMAW ? YES 3 SEARCH for pulse = NO ? YES 4 SEARCH for wire = Steel ? YES [ TYPE ] SEARCH HELP

  4. 12 SETTING UP A WELD SCHEDULE TO TO USE DESIRED WELD PROCESS PRESS DATA KEY TO DISPLAY WELD SCHEDULES. FIRST COLUMN INDICATES WIRE FEED SPEED. SECOND COLUMN INDICATES TRIM/VOLTAGE SETTING. THIRD COLUMN IS FOR WELDING TRAVEL SPEED. ZERO LINE 0 DATA\Weld\Sched\\\\\\\\\\\\\\JOINT\\10\% 1/64 IPM COMMENT 1 \300.0 23.5 25 2 300.0 23.5 35 3 300.0 1.0 35 4 300.0 1.0 35 5 300.0 1.0 35 6 300.0 1.0 35 7 300.0 1.0 35 8 300.0 1.0 35 9 300.0 1.0 35 [ TYPE ] DETAIL HELP > F2 TO SETUP A WELD SCHEDULE, FIRST MAKE SURE THE DESIRED WELD PROCESS HAS BEEN SELECTED IN THE WELD PROCESS SETUP SCREEN. THEN CURSOR TO DESIRED SCHEDULE NUMBER AND PRESS F2-DETAIL. SEE SCREEN BELOW:

  5. 12 DETAIL VIEW OF WELD SCHEDULE 2 CURSOR TO LINE 2-PROCESS SELECT, KEY IN WELD PROCESS NUMBER(1-8) THAT WAS JUST SELECTED. CURSOR TO LINE 3- KEY IN DESIRED WIRE FEED SPEED CURSOR TO LINE 4- FOR POWERWAVE CV PROCESSES, KEY IN DESIRED WELD VOLTAGE(0-50). FOR POWERWAVE PULSE PROCESSES, KEY IN DESIRED TRIM VALUE(.5-1.5) LINE 5-FOR PINCHING THE ARC; WAVE CONTROL FOR PULSING, ADJUST FREQUENCY ZERO LINE 0 DATA\Weld\Sched\\\\\\\\\\\\\\JOINT\\10\% 1/7 1 Weld Schedule: 2 [****************] 2 Process select: 1 [GMAW Steel ] 3 WFS 300.00 ipm 4 VOLTS 23.500 V 5 Pinch 0.00 6 Travel speed 35 IPM 7 Delay Time 0.00 sec Feedback Avg Voltage 0.0 V Feedback Avg Current 0.0 A [ TYPE ]SCHEDULE HELP > STT ONLY: LINE 4 WILL INDICATE BACKGROUND CURRENT, RANGE IS TYPICALLY FROM 40 TO 80 AMPS LINE 5 WILL INDICATE PEAK CURRENT, RANGE IS TYPICALLY FROM 150 TO 300 AMPS

  6. 10 WELD EQUIPMENT SCREENS FOR STT SETUP NOTE STT IS ON DESC. LINE SETUP\Weld\Equip \\\\\\\\\\\JOINT\\10\% 1/17 Welder:Lincoln Electric PowerWave+ArcLnk 1 Process: 1 GMAW Steel # 112 Wire diameter: [ .035 in] Gas mixture: [Ar CO2 ] Description: [STT ArCO2 ] 2 SEARCH for process = GMAW ? YES 3 SEARCH for pulse = NO ? YES 4 SEARCH for wire = Steel ? YES [ TYPE ] SEARCH HELP STT HAS IT'S OWN UNIQUE SET OF MODE/ MEMORY NUMBERS USE NO FOR PULSE ! SETUP\Eq\Search \\\\\\\\\\\JOINT\\10\% 10/17 ] 9 111 .035 in [GMAW Steel ] [STT CO2 ] [100% CO2 ] 10 112 .035 in [GMAW Steel ] [STT ArCO2 ] [Ar/CO2 Blends ] [ TYPE ] SELECT HELP EXAMPLE OF SEARCH RESULTS SHOWING MATCHES INVOLVING STT

  7. 11 COMPLETE WELD EQUIPMENT SCREEN SETUP\Weld\Equip\\\\\\\\\\\\\JOINT\\10\% 1/17 Welder:Lincoln Electric PowerWave 455 1 Process: 1 GMAW Steel # \21 Wire diameter: [ .045 in] Gas mixture: [Ar CO2 ] Description: [CV ArMix ] 2 SEARCH for process = GMAW ? YES 3 SEARCH for pulse = No ? YES 4 SEARCH for wire = Steel ? YES Feeder: Power Feed 10 5 Wire feed speed units: IPM\\\ 6 WIRE+ WIRE- speed: 50 IPM 7 Feed forward/backward: ENABLED 8 Wire stick reset: ENABLED 9 Wire stick reset tries: 1 Timing: 10 Arc start error time: 2.00 sec 11 Arc detect time: 0.06 sec 12 Arc loss error time: 0.25 sec 13 Gas detect time: 0.05 sec 14 Gas purge time: 0.35 sec 15 Gas preflow time: 0.00 sec 16 Gas postflow time: \0.20 sec 17 Strike wire feed speed 50\ IPM [ TYPE ] SEARCH HELP

  8. 13 PW455 MODE/ MEMORY NUMBER 8 GROUPS OF 4 ITEMS ; 32 TOTAL LINES. EACH GROUP IS FOR EACH OF THE WELD PROCESSES SETUP IN THE WELD EQUIP. SCREEN. ONLY THE FIRST 8 LINES, FOR PROCESSES 1 AND 2, ARE VALID ARCTOOL S/W 5.20 AND BEFORE. WHEN YOU CURSOR DOWN TO LINE 5, PROCESS SELECT 2 NOW APPEARS AT TOP OF SCREEN, LINE 9, PROCESS SELECT 3, ETC. CURSOR TO DESIRED LINE AND PRESS F2-DETAIL TO SETUP SPECIFICS

  9. 14 WELD PROCESS SCREEN (cont.) DATA\Weld\Process\\\\\\\\\\\\JOINT\\10\% 1/4 Schedule: 6 [ Burnback ] Process select: 2 [GMAW- Steel ] 1 WFS \300.0 ipm 2 VOLTS 25.000 3 Wave Control 1 10.000 4 Delay Time 0.05 sec [ TYPE ]SCHEDULE HELP >