1 / 17

A New Laboratory Test of the Equivalence Principle

A New Laboratory Test of the Equivalence Principle. R.D. Reasenberg and J.D. Phillips Smithsonian Astrophysical Observatory Harvard-Smithsonian Center for Astrophysics. APS Meeting, Jacksonville Florida, 14 April 2007. Roland E ö tvös 1922, 5 10 -9 Robert Dicke 1964, 1 10 -11

merton
Download Presentation

A New Laboratory Test of the Equivalence Principle

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A New Laboratory Test of the Equivalence Principle R.D. Reasenberg and J.D. Phillips Smithsonian Astrophysical Observatory Harvard-Smithsonian Center for Astrophysics APS Meeting, Jacksonville Florida, 14 April 2007

  2. Roland Eötvös 1922, 5 10-9 Robert Dicke 1964, 1 10-11 Vladimere Braginsky 1972, 1 10-12 Eric Adelberger today Torsion balances are exquisitely sensitive force detectors. Solar and horizontal gravity down by 10-3. Depends on mechanical behavior of stressed fiber.

  3. Alternative: Galilean test. • Faller and Niebauer at JILA: σ (Δg) / g = 5 × 10-10 • Limited by systematic error associated with lateral separation of falling masses in separate chambers.

  4. POEM Chamber Optics, Gen-I Key Technologies: Laser gauge; Capacitance gauge; Motion system. POEM long-term goal: σ(η) = 5 10-14 requires second pair of TMA

  5. Gen-I TMA Φ = 44.5 mm h = 36.5 mm

  6. Stabilized Laser Frequency Shifter (ADM) Phase Modulator L ~ fm VCO VFS Frequency Counter Int (Hopping) Controller Analog Output TFG, Classic Realization Tracking Frequency laser Gauge: loop closed by Pound-Drever-Hall locking.

  7. Measurement Precision TFG early results: Nov 1991 σ(length) < 2 pm, 1 min < τ < 400 min 10 pm For 1 pm @ 1 s, Q = 0.8 s, R = 0.3, σ(η) = 1.1 10-11, single toss. σ(Δg)/g = 5 10-14 => 5.1 104 tosses (22 hours ) 1 pm 1 s 10,000 s

  8. ~ Tunable Laser Phase Modulator L VFS Reference Laser fm Int Frequency Counter Analog Output Hopping Controller New TFG

  9. + + - - ~ POEM Capacitance Gauges Collaboration with Winfield Hill, Rowland Institute at Harvard Vacuum TMA Correlator s/w in PC f1, f2, …, f5 ADC 24 bit 100 kHz Estimates of 5 positions (x, y: top and bottom & z) per TMA, at 1 kHz Cal. f1 Moving Static

  10. Drive: 0.1 V rms, 10 – 20 kHz Sensitivity: < 8 nm @ 1 s. Electrode gaps: 1 mm (nominal)

  11. Motion System Requirements • Follow free-falling TMA. • Rapid reversal of motion at bottom. • Minimize shock, vibration & energy loss. • Lateral velocity deviation < 10 μm/s. • Simplify Coriolis correction. • Smooth transition through zero-g to launch TMA. • Structural resonances high. • Avoid interaction with motion servo.

  12. Present Motion System • Slide (commercial). • Follow nominal trajectory. • Torsion bar bouncer. • Store and return energy. • Do no harm. (Cause no shock.) • Horizontal cable hit by moving system. • Soft onset of force on moving system, from geometry. • Effective mass of cable, 0.05 kg (chamber, 40 kg).

  13. New Motion System • Granite beam as way for air bearings. [ordered] • Porous graphite air bearings. [stock items] • Aluminum box to hold bearings. [parts ordered] • HEIDENHAIN linear position encoder.* • Aerotech motor controller.* • Massive steel base. [designed] • Mechanical modes > 40 Hz. * Corporate donation.

  14. A B B A Systematic Error, I • Earth’s gravity gradient. • Δg / g = 1.6 10-7 (for Δh = 0.5 m) • Goal (TMA): σ (Δg) / g = 1.5 × 10-14 • => require σ(Δh) < 0.05 μm. • Second pair of TMA. • Absolute distance measurement. • Top-bottom interchange. • Requires breaking vacuum => separate runs 1 or 2 days apart.

  15. Systematic Error, II • Gravity gradient due to local mass (parked cars). • SUV assumed 2000 kg, on street, 9 m from TMA. • On street closest to TMA => 9 10-12 g (top-bottom). • Second pair of TMA. • SUV, worst location (26 deg) => 6.2 10-14 g (double diff.) • Inventory of cars during night. • Model using estimated masses. • Frequent left-right interchanges of TMA, if needed. TMA separation (70 mm) → seating error (<< 0.1 mm). Would address all variabilities in local gravity.

  16. Systematic Error, III • Coriolis force and transverse velocity. • Capacitance gauge measures velocity. • Require ve-w be measured to 33 nm/s [bias < 0.25 nm/s]. • Air slide reduces vibration => reduced transverse velocity, and thus dynamic range requirement. • Rotation of TMA around horizontal axis. • Vertical offset, optical reference point from CM, εz=2 μm; 1 mrad/s rotation: δa=2×10-13 g • Measure rotation with capacitance gauge and calibrate εz by inducing fast rotation via high voltage on capacitance gauge electrodes. • Correction to 0.5×10-14 g.

  17. More Information • www.cfa.harvard.edu/poem • reasenberg@cfa.harvard.edu • 617-495-7108 • jphillips@cfa.harvard.edu • 617-495-7360

More Related