Learn about the design, assembly, and alignment procedure for the BFW Card in the physics experiment, including wire mounting, tooling, and status updates. Card alignment plan, fiducials, and adjustment screws detailed.
E N D
BFW Card Physics Requirements Status - BFW Card design - Carbon wire mounting and tooling BFW card alignment procedure Clive Field, Reggie Rogers, Venkat Srinivasan
BFW Assembly Overview (J. Bailey) BFW Wire Schematic (1.4-004-r1) • SLAC Deliverable: • BFW Card • Detection mechanism • Cabling • 90 psi airline; 24V solenoid controller Assembly model courtesy: J. Bailey, ANL
BFW Card Prototype Drawing X-wire end point: 39.614 mm Beam center: 40 mm Gap between beam and X-wire: 0.386 mm Prototype material: Al-6061 Actual material: Macor Thickness: 3/16” (4.8 mm) Coating: Kovar [tooling in progress] Y-wire end point: 37.014 mm Beam center: 37.2 mm Gap between beam and Y-wire: 0.186 mm
BFW Card Wiring: Tooling Micrometer stage BFW Card Rods for hanging BFW wire with weights Card holder ‘Carbon wire & weight’ Copper Tabs • Wires soldered to copper tabs • Wires from copper tabs connect to BFW feedthrough • Feedthrough to be grounded and RF shielded
BFW Card: Alignment Plan Slide Fiducials Vertical and Horizontal Adjustment Screws • Place BFW assembly on bench assembly using flange locating pins • Bench assembly locates on CMM • Locate wires to local fiducials (card edges and hole) – optically. • Locate local fiducials to outside tooling balls – using CMM. • Card’s alignment pin holes are slotted in horizontal direction. • Card’s horizontal position is verified/altered using shim/thickness gages. Flange Locating Pins Pneumatic supply Bench Fiducials Adjustment Bench located on CMM Wire Card Fiducials are edges of card and additional hole at bottom of card Use shim/thickness gages to measure gap between card holder and card Assembly model courtesy: J. Bailey, ANL