MGCS-Energy MGCS-Energy Audit Company Check us at http://www.mgcs.net.in/hvac_energy_audit.php
We conduct Energy Audit for all Electrical equipments, all Electrical equipments, HVAC Equipments etc. Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Major Components for Energy Audit for HVAC Systems are: •Chillers •Pumps •Motors •Motors •Cooling Towers •Air Handling Units Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Chillers •Measuring all the operating parameters such as water flow inlet &out water temperatures, gas suctions &discharge pressure, Power Consumption etc. Consumption etc. •Calculation of operating Input KW per TR (IKW I TR) of Chiller(s) for each chiller. Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Pumps •Measuring all the operating parameter such as water flow, suction &discharge head, power consumption etc. Performance Evaluation of chilled water &Condenser water pumps and compare •Performance Evaluation of chilled water &Condenser water pumps and compare the same with the design or generally expected efficiency of such pumps. Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Cooling Towers •Measurement of various parameters for cooling tower fans, water flow rate, air flow rate, dry bulb temperature (DBT) wet bulb temperature (WBT) sump temperature, relative humidity etc. temperature (WBT) sump temperature, relative humidity etc. •Evaluation of cooling tower performance (Range, approach, and effectiveness). Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Air Handling Unit •Measurement of airflow, Relative Humidity(RH), Supply air temperature (Tsa), Return air temperature (Tra), Chilled Water Inlet and outlet temperature i.e. Tin, Tout through cooling coil and energy consumption of Air Handling Units (AHUs). Examination of Air Handling Units for air delivery capacity, capacity utilization, •Examination of Air Handling Units for air delivery capacity, capacity utilization, temperature pattern, pressure drop and operational pattern with respect to time. •Calculation of actual tonnage of AHUs and Measurement of operating zone Temperatures under each unit. Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Get Energy Audit done now Manage Energy Use Reduce your Energy Consumption Lower your Energy Bills Prevent Voltage Fluctuations Prevent Voltage Fluctuations Check us at http://www.mgcs.net.in/hvac_energy_audit.php
MGCS professional audit can help in: ?Reducing your energy bills ?Correction Power Quality Issues ?Managing Energy Consumption ?Managing Energy Consumption ?Safety from Electrical Hazards ?Energy Conservation for future Check us at http://www.mgcs.net.in/hvac_energy_audit.php
?We have got BEE (Bureau of Energy Efficiency) Certified Energy Auditors on board to help you on Energy Management System ?We use all gadgets and instruments from leading brands across the globe for fine accuracy and precision Check us at http://www.mgcs.net.in/hvac_energy_audit.php
Contact us now & save on Energy & Money Write us at hina.gupta@mgcs.net.in for any query L -011-49040941/42/43 Check us at http://www.mgcs.net.in/hvac_energy_audit.php