1 / 23

Radiometry and Uncertainties from SORTIE: Investigating Subpixel Variability in Vicarious Calibration

This study examines radiometric techniques and uncertainties in vicarious calibration using inherent optical properties (IOPs) to determine subpixel variability in Case II waters. The research includes experiments in Hawaii and San Diego, comparing data from MOBY, Satlantic, and NIST sensors. Preliminary results show good agreement between laboratory intercomparisons and measurement estimates of upwelled radiance distribution.

mgrimes
Download Presentation

Radiometry and Uncertainties from SORTIE: Investigating Subpixel Variability in Vicarious Calibration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radiometry and Uncertainties from SORTIE(Spectral Ocean Radiance Transfer Investigation and Experiment) Kenneth Voss and Howard Gordon, Univ. of Miami Marlon Lewis, Scott McLean and Mike Twardowski, WetSat Carol Johnson, NIST Mark Yarbrough, Stephanie Flora and Mike Feinholz, Moss Landing Marine Lab Chuck Trees, NURC, NATO (SORTIE also includes Ron Zaneveld, Andrew Barnard, Susanne Craig) 2008 NASA Carbon Cycle and Ecosystems Joint Science Workshop, May 1

  2. Sortie Goals • To test radiometric techniques to augment the current vicarious calibration methods. • The basic idea is to use measurements of inherent optical properties (IOP’s) to extend the radiometric measurements and determine subpixel variability • To determine the suitability/ability to collect a usable vicarious calibration data set in Case II waters, in the best possible case.

  3. SORTIE method • Start with the very well characterized radiometric instrumentation • Collect a complete suite of radiometric and apparent optical property (AOP) measurements during overpass time (Lu, Ed, L(q, f), KLu, KEd, +) • Collect IOP’s synchronous with these measurements, and then use a towed vehicle to investigate the IOP field around the measurement site before and/or after the overpass

  4. First experiment in Hawaii, second in San Diego • Start with clear water experiment, cross-over with MOBY and the MOBY team (experiment done last March) • If you can’t make clear water work, Case II is crazy • Move to coastal region, San Diego (experiment done in January) • More difficult optical field (variation in IOP’s within pixel) • Important for vicarious cal…different “colored” sources…out of band issues accentuated

  5. Hawaii experiment • Cross over with the MOBY buoy, the “gold standard” for vicarious calibration • Vicarious calibration in clear water, clear atmosphere • Laboratory component, before field work, to set a baseline….if it doesn’t work in the lab why expect it to work at sea.

  6. Responsivity uncertainties from laboratory calibration: Temperature uncertainty is after correction, as is stray light.

  7. Laboratory comparison experiment Compare MOBY and Satlantic E and L instruments Look at radiometric calibration sources Look at filtered sources, which can point out issues with out-of-band or stray light. If it doesn’t work at sea, data set gives another place to look.

  8. Some examples, L from MOBY and Satlantic HPL

  9. Colored Radiance source

  10. Irradiance, standard calibration source

  11. At Sea comparison • Obviously harder….as close to contemporaneous as possible (within 900m) • Newest Satlantic algorithm (see Scott McLean’s poster) • Day shown was very clear (cloud free) and calm

  12. MOBY and Satlantic Hyperpro

  13. Different view

  14. Still working….. • But the SORTIE data set, very high quality IOP and AOP, gives us all sorts of other places to explore: • Nurads Radiance distribution with MASCOT VSF (and other Wetlabs IOP’s) • Inversion of Satlantic profile to get IOP’s to compare with measurements

  15. Predicting Radiance distribution with VSF

  16. Inversion techniques to go from AOP’s to IOP’s • Based on algorithms detailed in: • H.R. Gordon and G.C. Boynton, “A radiance - irradiance inversion algorithm for estimating the absorption and backscattering coefficients of natural waters: Stratified water bodies”, Applied Optics 37, 3886-3896 (1998). • G.C. Boynton and H.R. Gordon, “An irradiance inversion algorithm for absorption and backscattering coefficients: Improvement for very clearwaters” Applied Optics, 41, 2224—2227 (2002). • Really sensitive to reflectance and gradients (K) so is not dependent on absolute radiometry

  17. Example inversion of single wavelength Fairly constant offset on order of 0.005 m-1, within published instrument uncertainties

  18. Hyperspectral bb and a inversion

  19. Hyper spectral c from inversion(?) No real reason it should be this good. b estimate depends on phase function assumed..

  20. San Diego Experiment • Have most of the data processed, not all • Some very good days • a good contrast to the Hawaii data set in terms of optical properties in the water.

  21. Conclusions • These are preliminary results. Still determining, in a collaborative manner, if there are areas for improvement. • The laboratory intercomparisons between MOBY, Satlantic, NIST radiance and irradiance sensors are quite good and within 2%, well within the instrumental uncertainty budget.    • There are some biases between MOBY and HyperPro derived water-leaving radiances in the field data, which remain unexplained at this point, but are likely due to differences in deployment and environmental variations. •  Measured IOP's plus RTE (both Gordon and Morel approaches) provide excellent estimates of the upwelled radiance distribution. • The inversion of the HyperPro AOP profiles provides a remarkably good agreement with direct measurements of IOP's. •  While the agreement for c is fortuitous, the agreement with a and bb emphasizes the excellent calibration (and baseline correction) of the AC-9 for use in these very clear waters. •  Next step is to apply same approach to San Diego Data set. • We will be doing another field experiment in the fall in the Ligurian Sea, near the Bousolle site.