220 likes | 365 Views
Status of PMCS_EM package. Junjie Zhu University of Maryland. Outline. Introduction Smearing Algorithm Method used to determine smearing parameters from D0reco Results from pmcs_em package 1. Z ee 2. W e Summary. Introduction.
E N D
Status of PMCS_EM package Junjie Zhu University of Maryland PMCS meeting
Outline • Introduction • Smearing Algorithm • Method used to determine smearing parameters from D0reco • Results from pmcs_em package • 1. Z ee • 2. W e • Summary PMCS meeting
Introduction • PMCS_EM package is used to fast simulate behaviors of EM objects • Since electrons and photons have almost the same behavior in EM calorimeter, they are smeared the same way • Smear electrons at generator level PMCS meeting
Smearing Algorithm • Generator-level electrons are first extrapolated to the EM3 layer, and depending on their positions, different parameters are used to smear them • For each electron, adjust the energy scale, smear energy, detector eta and phi PMCS meeting
x: random number generated from Gaussion distribution a, b are energy scale constants C: Constant term S: Sampling term N: Noise term : energy resolution : detector eta resolution : phi resolution Smearing Algorithm PMCS meeting
method to get parameters from D0reco • Need to get the corresponding parameters from D0reco, assume D0reco is absolutely right (for now) • 14 Event Samples (single energy electrons) • D0reco and Reco_analyze Version: p10.11.00 • Electron energy: 5, 10, 20, 30, 50, 80, 100, 120, 150, 200, 220, 250, 300, 400Gev • Each sample contains 6,000 events, no pile up, flat in space PMCS meeting
Electron Types • Electrons in EM3 layer are divided into six types: • In CC, pass CPS, not in Crack region • In CC, pass CPS, in Crack region (5% from both sides) • Only in EC, • In EC, pass one shower layer of FPS • In EC, pass two shower layers of FPS • Only in EC, • Type 3 and 6 are different since they have • different detecor acceptance, energy scale are also • supposed to be different PMCS meeting
Electron Types Electrons in other regions: 7. ICD region with 8. Very forward region with are not smeared and also not stored . PMCS meeting
Energy scale constants PMCS meeting
Constant, Sampling and Noise terms PMCS meeting
Detector Eta resolution PMCS meeting
Phi Resolution PMCS meeting
Results from pmcs_em • Pmcs_em package are tested by two event samples: • 1. 1000 Z ee events <MinBias>=2.5 • 2. 1000 W e events <MinBias>=2.5 • Blue histogram for D0reco, Red histogram for pmcs PMCS meeting
Detector and Physical Eta (Z ->ee) PMCS meeting
Detector and Physical pT (Z ->ee) PMCS meeting
Phi (Z ->ee) PMCS meeting
Invariant Mass (Z ->ee) PMCS meeting
Invariant Mass (Z ->ee) PMCS meeting
Detector and Physical Eta (W ->enu) PMCS meeting
Detector and Physical pT (W ->enu) PMCS meeting
Phi (W ->enu) PMCS meeting
Summary • Electrons in pmcs_em package seem to agree well enough with D0reco electrons • C, S and N getting from D0reco with big errors, need to derive it from real data • Have started tuning pmcs to real data • Code will soon be released PMCS meeting