An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Noise Studies on APD and Crystals We connected to a CV meter and to the test board for FPPA: APD APD+CRYSTALS Capacitors The goal is to see how different from a pure capacitors the APD or APD+CRYSTALS systems are.

  2. SET-UP

  3. Capacitance measurements The APD and APD+CRYSTAL systems are identical, with a capacitance at full depletion of 165-170 pF

  4. Noise Measurements We studied the noise induced by the APD or APD+CRYSTALS as a function of the bias voltage. This noise is due to their capacitance plus some extra component... Values for a pure capacitor: 598pF --> 1.2 mV 168pF --> 0.9 mV 0 pF --> 0.5 mV 168 pF 550pF

  5. Comments - The noise generated by an APD is almost identical to what is induced by an equivalent capacitor. - The noise induced by the APD+CRYSTAL is very dependent upon the conditions used (wrapping, no wrapping, ground, shields..) In the best case it was a 20-30% higher than a pure APD. - We need to study more realistics set-ups. ALVEOLA+....