An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Timothy Carlisle Oxford Tracker Reconstruction

  2. Reconstruction in G4MICE • Simulate  Digitize  Reconstruct • TrackerRec/ package • 4 or 5 point tracks (Kalman fit) • root files for each Tracker Station • No TrackerRef Plane as yet • Use station 1 as ref.  innermost stations

  3. Downstream Tracker Upstream Tracker Track Fitting Efficiency 99% 99% Inner station Inner station 10,000 muons 6mm beam Two Trackers, no material Step IV fields

  4. x Resolution • 10,000 events, e =6mm • Res. 0.7 mm at stations 1 & 2 • Res. ~1.2 mm at outer stations • Feature of fitting algorithm? Station 5 Station 1 10,000 muons 6mm beam Step IV fields

  5. Momentum Resolution Px Pz • (mcPx-TrkPx) ~ 1 MeV/c • (mcPz-TrkPz) ~3.7MeV/c 10,000 muons 6mm beam Step IV fields

  6. dE/dX? • Landau distribution is ~3 MeV wide • Ptotal resolution ~ 3.9 MeV/c • Pz res. the weak link • EMR / ToFs? Ptotal

  7. Transverse Amplitude • Single particle emittance • Useful for selection cuts • Beastly: • Calc. using mc trutha b g for beam envelope

  8. Amplitude Resolution • 0.3mm < DAmpSq< 0.8mm depending on the station • Unclear why sign change... Station 5 Station 1 (Inner) 10,000 muons 6mm beam Step IV fields

  9. [Crude] Cooling Measurements • 35cm LH2 • Calc. e at each station • Inner station  ref. plane • 4.5% cooling (mc truth) • TrkMC: 5.5% • TrkRec: 3.8% Emittance [mm] Black – mc [Virtual Planes], 98.5% Transmitted Green – Trk mc Blue – reconstructed 10,000 muons 6mm beam Two Trackers, LH2 Step IV fields Abs(mc – rec) < 50 for x, y, px, py

  10. Energy • few MeV loss due to stations • Rec. Energy ~ const. • Averaged for rec. tracks? Av. Energy [MeV] Black – mc [Virtual Planes] Green – Trk mc Blue – Trk reconstructed

  11. Summary • TrackerRec/  Station by Station output at present • Efficiency 98-99% • Position resolution dep. on station • At inner station: • Energy resolution ~ 4MeV • Beyond Landau width- use EMR / ToFs? • Amplitude resolution appears < 1mm • sDx, Dy~0.7mm • sDPx,DPy~ 1 MeV/c • sDPz~ 3.7 MeV/c