1 / 16

Use Optical Measurement of Subcutaneous Abnormal Tissue of Portable Non-invasive System Design

Use Optical Measurement of Subcutaneous Abnormal Tissue of Portable Non-invasive System Design. Presenter: Bing- Soug Ho Adviser: Jenq-Ruey Horng Chairman : Hung-Chi Yang. OUTLINE. INTRODUCTION MATERIALS AND METHODS RESULT FUTURE WORK REFERENCE. INTRODUCTION. INTRODUCTION. 1,513.

minnie
Download Presentation

Use Optical Measurement of Subcutaneous Abnormal Tissue of Portable Non-invasive System Design

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Use Optical Measurement of Subcutaneous Abnormal Tissue of Portable Non-invasive System Design Presenter: Bing-Soug HoAdviser: Jenq-RueyHorng Chairman : Hung-Chi Yang

  2. OUTLINE • INTRODUCTION • MATERIALS AND METHODS • RESULT • FUTURE WORK • REFERENCE

  3. INTRODUCTION

  4. INTRODUCTION 1,513

  5. INTRODUCTION • Hospital have examination: • Tissue sections • X-ray • MRI • CT

  6. INTRODUCTION • Non-invasivedesign: • Body’s HB and HBo2 of light absorption • Hypodermal 2-3cm • Fast measurement • Cost down • Smalland portable

  7. MATERIALS AND METHODS

  8. MATERIALS AND METHODS 660 940 Fig.1 Infrared absorptionspectrum NIR:近紅外線(700nm~ 2,000nm) Infrared absorptionspectrum:紅外線吸收光譜

  9. MATERIALS AND METHODS Fig.2diffraction & scattering

  10. MATERIALS AND METHODS Fig.3 System architecture

  11. MATERIALS AND METHODS • LED660nm(Red) and LED940nm(white): LED660nm Detector 1.7cm LED940nm Fig.4

  12. RESULT

  13. RESULT • New Entity Fig.5 Fig.6

  14. RESULT • Measurement Entity Fig.7

  15. FUTURE WORK • Collect more Phantom data • Indicate tumor direction

  16. REFERENCE • [1].Department of Health, Executive Yuan, R.O.C.(TAIWAN) • [2].Zhao, Zhongyao, et al. "Handheld tumor scanner for breast cancer detection." (2006). • [3]. http://www.bli.uci.edu/ntroi/pubs/pdf/si_recipe.pdf • [4]. Lelia Adelina Paunescu” TISSUE BLOOD FLOW AND OXYGEN CONSUMPTION MEASURED WITHNEAR-INFRARED FREQUENCY-DOMAIN SPECTROSCOPY” Submitted in partial fulfillment of the requirementsfor the degree of Doctor of Philosophy in Biophysics and Computational Biologyin the Graduate College of theUniversity of Illinois at Urbana-Champaign, 2001

More Related