SERVO-i WITH HELIOX OPTION. GROWING WITH THE CUSTOMER’S NEEDS . SERVO-i System Version 4.0. Heliox option Low MV alarm audio off option Possibility to switch off back-up ventilation Other usability improvements. HELIOX – GAS PROPERTIES. What is Heliox?.

misu
Download Presentation

SERVO-i WITH HELIOX OPTION

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SERVO-i WITH HELIOX OPTION

  2. GROWING WITH THE CUSTOMER’S NEEDS SERVO-i System Version 4.0 • Heliox option • Low MV alarm audio off option • Possibility to switch off back-up ventilation • Other usability improvements

  3. HELIOX – GAS PROPERTIES What is Heliox? • Heliox – HeO2 – is a mixture of helium (He) and oxygen (O2) (e.g. 80/20; 70/30). • Helium is an inert, low density gas (~1/7 the density of air and oxygen). • Lower density leads to a more laminar flow (less turbulence) and thus reduces resistance in the airways.

  4. HELIOX – GAS PROPERTIES • Laminar gas flow (A) is more efficient than turbulent flow (B).

  5. HELIOX – EFFECTS ON VENTILATION Effects of Heliox therapy according to the literature • Established positive effects on ventilation • Reduces work of breathing • Increases CO2 diffusion • Potential positive effects on ventilation • Reduces the peak pressure needed to maintain flow • Increases CO2 elimination and improves gas exchange • Increases expiratory flow • Reduces respiratory rate and auto PEEP • Increases drug deposition in distal parts of the airways.

  6. HELIOX – USES AND APPLICATIONS For which patients is Heliox most commonly used? • Upper airway obstruction • Lower airway obstruction

  7. HELIOX – POTENTIAL BENEFITS Potential benefits of Heliox therapy according to the literature • Avoiding endotracheal intubation • Protecting the lungs • Improving patient outcome • Enhancing patient comfort

  8. SERVO-i WITH HELIOX OPTION General • Available as an option for the SERVO-i • Field upgrade • Factory installed • The option consists of: • Heliox SW • Heliox adapter kit

  9. SERVO-i WITH HELIOX OPTION Functionality • Can be used with all pediatric and adult patients, as well as neonates • Compatible with all invasive/non-invasive ventilation modes • Supporting mobility from emergency room to MR environment • Connection of 80/20; 79/21; 78/22 mixtures possible • Adjustable O2 concentration (21 to 100%).

  10. SERVO-i WITH HELIOX OPTION Key benefits of using SERVO-i for Heliox therapy • Unique solution for automatic gas identification • Automatic compensation of flow delivery • Automatic compensation of CO2 and volume monitoring

  11. SERVO-i WITH HELIOX OPTION Key benefits of using SERVO-i for Heliox therapy • Quick and easy start of therapy • Quick and easy switch from air to Heliox (and vice versa) without going to standby • User friendly interface • Cost efficient Heliox therapy thanks to the SERVO-i’s low gas consumption.

  12. SERVO-i WITH HELIOX OPTION Heliox adapters • Four different adapters are available: • DISS (both air (A) and Heliox (B)) • NIST/NIST • AGA/NIST • French/NIST

  13. SERVO-i WITH HELIOX OPTION Heliox adapters • Color marked for Heliox • Brown/green for Heliox DISS • Brown/white for Heliox NIST • Attached to ventilator with safety wire • Attach to air module when using Heliox

  14. SERVO-i WITH HELIOX OPTION Connecting Heliox to the ventilator – Heliox adapters NIST / AGA / French • Remove adapter from holder. • Connect adapter to Heliox high pressure hose. • Connect adapter to air module inlet.

  15. SERVO-i WITH HELIOX OPTION Preparations before using Heliox with SERVO-i

  16. SERVO-i WITH HELIOX OPTION Automatic gas identification • Performed by the ultrasonic expiratory flow sensors • Available during Pre Use Check and during ventilation • Active as long as the set O2 concentration is 75% or below • Time for identification is determined by tidal/minute volume and O2 concentration used

  17. SERVO-i WITH HELIOX OPTION Pre Use Check

  18. SERVO-i WITH HELIOX OPTION Automatic identification when changing from air to Heliox during ventilation

  19. SERVO-i WITH HELIOX OPTION Gas type change – manually initiated compensation for Heliox gas

  20. SERVO-i WITH HELIOX OPTION Gas type change – manually initiated compensation for Heliox gas

  21. SERVO-i WITH HELIOX OPTION Gas type change – manually initiated compensation for Heliox gas

  22. SERVO-i WITH HELIOX OPTION Non-invasive application

  23. SERVO-i WITH HELIOX OPTION Infant application

  24. SERVO-i WITH HELIOX OPTION Order information • The Heliox option is not compatible with the O2 Sensor and Y Sensor measuring.

  25. SERVO-i 4.0 – OTHER IMPROVEMENTS/CHANGES Low Minute Volume alarm audio off

  26. SERVO-i 4.0 – OTHER IMPROVEMENTS/CHANGES Low Minute Volume alarm audio off

  27. SERVO-i 4.0 – OTHER IMPROVEMENTS/CHANGES Low Minute Volume alarm audio off

  28. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Possibility to disable back-up ventilation

  29. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Possibility to disable back-up ventilation

  30. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Possibility to disable back-up ventilation

  31. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Showing previous Pre Use Check/Suction Support FiO2 retention

  32. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Maintenance notifications/Changed calculation of time for next PM

  33. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Previous mode information/Initiating a Pre Use Check

  34. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES New alarm symbol/Clearer difference between medium and high priority alarms

  35. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES New patient category symbols

  36. SERVO-i/s 4.0 – OTHER IMPROVEMENTS/CHANGES Time scale on the waveforms Art. no. 6679957 rev. 01