520 likes | 528 Views
Type Topic in here!. Question 1 - 10. Part of the regulator that must always be kept clean. Answer 1 – 10. What is the “Vent Hole”. Vent Hole. Question 1 - 20. Never use a torch missing this part. Answer 1 – 20. What is the “Stand”.
E N D
Question 1 - 10 Part of the regulator that must always be kept clean.
Answer 1 – 10 What is the “Vent Hole” Vent Hole
Question 1 - 20 Never use a torch missing this part.
Answer 1 – 20 What is the “Stand”
Question 1 - 30 If a pressure regulator leaks check to see if this part is in place.
Answer 1 – 30 What is an “O” ring “O” Ring
Question 1 - 40 Use this tool to light a torch.
Answer 1 – 40 What is a “striker”
Question 1 - 50 Used for quick application of field rolls.
Answer 1 – 50 What is a “Torch Trolley” or “Dragon Wagon”
Question 2 - 10 What words does the term PASS stand for?
Question 2 - 20 Two of these must be within 10’ of torching operations.
Answer 2 – 20 What is two 4A-60BC fire extinguishers
Question 2 - 30 This must be in the fire extinguisher to ensure it has not been used.
Answer 2 – 30 What is a plastic seal band in place through the release pin.
Question 2 - 40 The safe distance that a fire extinguisher should be from a propane tank.
Answer 2 – 40 What is no closer than 10 feet 10 feet
Question 2 - 50 The types of fires a class A fire extinguisher should be used on.
Answer 2 – 50 What is • Wood • Paper • Plastic • Cloth
Question 3 - 10 Must be performed for 2-hours after last torch is turned off.
Answer 3 – 10 What is fire watch
Question 3 - 20 Secure in the center of the roof during fire watch duties
Answer 3 – 20 What are LP tanks
Question 3 - 30 Helps detect if under membrane smoldering or fire is occurring.
Answer 3 – 30 What is a Infrared Heat Detector
Questions 3 – 40 Eliminates hazards before the job starts
Answer 3 – 40 What is a Pre-Job Inspection
Question 3 - 50 Does not have to be CERTA certified but must be knowledgeable in his/her duties
Answer 3 – 50 What is the person performing fire watch
Question 4 - 10 Safest way to avoid fire hazards when torching at walls, penetrations, roof edges and unseen areas.
Answer 4 – 10 What is torch-and –flop method
Question 4 - 20 ¾ inch perlite ¾ inch fiberglass ¼ inch glass faced gypsum board
Answer 4 – 20 What are acceptable thermal barrier insulation boards
Question 4 - 30 Used for direct torching at walls and penetrations if acceptable thermal air barrier is in place.
Answer 4 – 30 What is a Detail Torch
Question 4 - 40 Shut off the torch
Answer 4 – 40 What is if you leave a torch unattended
Question 4 - 50 A lit torch must only be placed here
Answer 4 – 50 What is the “Stand”
Question 5 - 10 All torch applicators should be trained in these safe practices.
Answer 5 – 10 • Fire hazards recognition • LP equipment safety • Wear appropriate PPE • Proper use of a fire extinguisher
Question 5 - 20 Up to date inspection tags on the fire extinguishers provide guarantee that….
Answer 5 – 20 What is fully charged
Question 5 - 30 Careless torch activities lead to this.
Answer 5 – 30 What is unemployment
Question 5 - 40 Never torch directly to
Answer 5 – 40 What are Combustible Substrates