370 likes | 515 Views
1. Outdoor units lineup. 6HP. New. New. New. 6HP. J Series. S Series. V Series (8–42HP). Type. Small System. Standard System. Plus System. Refrigerant. R410A. R407C/R22. R410A. Cooling Only. 8HP. 10HP. 8HP 10HP 14HP. Heat Pump. 8HP. 10HP.
E N D
Outdoor units lineup 6HP New New New 6HP JSeries S Series VSeries (8–42HP) Type Small System Standard System Plus System Refrigerant R410A R407C/R22 R410A Cooling Only 8HP 10HP 8HP 10HP 14HP Heat Pump 8HP 10HP (Master/Slave) (Master/Slave) (Master/Slave) Heat Recovery 10HP (R407C only) 2
Why V series required? Large scale Building: Request to save space of rooftop and pipe shaft
DESIGN FREEDOM DESIGN FREEDOM 24
DESIGN FREEDOM DESIGN FREEDOM Connectable large capacity Indoor units up to 150% of the capacity of the outdoor unit can be connected Max. connectable capacity150% Max. connectable indoor units48 Note : When all indoor units are operating at maximum capacity individual indoor units operate at a slightly lower capacity. (When connecting more than 100%) 25
Height difference between outdoor and indoor units Actual pipe length 150mmax. 50mmax. Height difference between indoor units 15mmax. DESIGN FREEDOM DESIGN FREEDOM Long piping system design For the outdoor unit stated below : 40m max. Pipe length from first separation tube to the farthest indoor unit 60mmax. 26
DESIGN FREEDOM DESIGN FREEDOM Low outdoor air temperature operation This extends the potential locations for use to the cold regions of the world. Extension of operating ranges *1 *1 27
DESIGN FREEDOM DESIGN FREEDOM Compact outdoor unit improves effective use of space 33.8% Space Save Installation space can be reduced freeing up valuable building space V series: 28HP system (14HP x 2 units) Space saving which can be effectively used 39m2 Conventional model: 28HP equivalent (10Hp x 2units, 8HP x 1 unit) 59m2 28
OUTDOOR UNITS OUTDOOR UNITS 33
OUTDOOR UNITS OUTDOOR UNITS Combination of outdoor units Various ability system can be united by combining one to three outdoor units if necessary. 8HP (22.4kW) 10HP (28.0kW) 14HP (40kW) 18HP (50.4kW) 28HP (80.0kW) 16HP (44.8kW) 20HP (56.0kW) 22HP (62.4kW) 24HP (68.0kW) 26HP (72.8kW) 30HP (84.0kW) 32HP (90.4kW) 36HP (102kW) 38HP (108kW) 42HP (120kW) 34HP (96.0kW) 34
OUTDOOR UNITS OUTDOOR UNITS 34
OUTDOOR UNITS OUTDOOR UNITS 34
OUTDOOR UNITS OUTDOOR UNITS 34
OUTDOOR UNITS OUTDOOR UNITS 34
OUTDOOR UNITS OUTDOOR UNITS AIRSTAGEVSeries change of connectable capacity limitation Connectable rated indoor unit capacity ratio is 50-150% of the rated outdoor unit capacity except the following points: ①In the case of adopting the following 3 conditions entirely, the connectable indoor unit capacity ratio becomes 75 – 150%. - Single system of outdoor unit capacity 8 or 10 or 14HP and - System uses heating operation and - System includes at least one indoor unit which capacity is less than 18,000BTU ②Minimum number of indoor unit in a system is 2 Except single connection of ARXC90 34
INDOOR UNITS INDOOR UNITS 44
1-1 EQUIPMENT SELECTION PROCEDURE / LINEUP ■ INDOOR UNIT LINEUP (1/2)
1-1 EQUIPMENT SELECTION PROCEDURE / LINEUP ■ INDOOR UNIT LINEUP (2/2)
INDOOR UNITS INDOOR UNITS Indoor units line up 11 types 50 models, ranging from 2.2kW to 25.4kW 45
INDOOR UNITS INDOOR UNITS Compact cassette / Cassette 46
INDOOR UNITS INDOOR UNITS Compact duct / Low static pressure duct / Duct / High static pressure duct 47
INDOOR UNITS INDOOR UNITS Floor / Ceiling 48
INDOOR UNITS INDOOR UNITS Compact wall mounted / Wall mounted 49
INDOOR UNITS INDOOR UNITS Ceiling wall 50
Options 41
Indoor units ■ REQUIRED OPTIONAL PARTS
Controllers ■ CONTROLLER UNIT LINEUP
Controlling ■ ADAPTOR / CONVERTOR LINEUP
Indoor units 7 to 84 14 to 90 7 to 60 174 to 560 181 to 567 7 to 252 ■ OPTIONAL PARTS (BRANCH KIT) (1/3) 90, 91, 180 and 181 are the total values for the indoor unit model code connected downstream. 84 to 173 91 to 180 7 to 90
Indoor units ■ OPTIONAL PARTS (BRANCH KIT) (2/3) 90, 91 180 are the total values for the indoor unit model code connected downstream.
Outdoor units ■ OPTIONAL PARTS (BRANCH KIT) (3/3)
Indoor units ■ OPTIONAL PARTS (OTHERS) (1/2)
Indoor and controlling ■ OPTIONAL PARTS (OTHERS) (2/2)
SERVICE & MAINTENANCE SERVICE & MAINTENANCE 41
SERVICE & MAINTENANCE SERVICE & MAINTENANCE Service tool (Software) Extensive monitoring and analysis functions for installation and maintenance Wiring connection Error history Equipment detail (Diagram) Equipment detail (List) 42
SERVICE & MAINTENANCE SERVICE & MAINTENANCE Web monitoring tool (Software) Support 4 VRF system Web monitoring system VRF System Side Monitoring Side 43