THE BEGINNING. CATU was created in 1919 by M. CATU and, since the beginning, it has dedicated its activity to the manufacture of material and equipment for electricity networks and installations. Since 1936, CATU ’s activity has been concentrated on equipment

monisha
Download Presentation

THE BEGINNING

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. THE BEGINNING CATU was created in 1919 by M. CATU and, since the beginning, it has dedicated its activity to the manufacture of material and equipment for electricity networks and installations. Since 1936, CATU ’s activity has been concentrated on equipment for personal protection against electrical hazards and accordingly, has now more than 80 years experience in this field. After the end of the World War II, many French companies involved in Production, Transmission and Distribution of Electrical Energy were almagamated into one National Company, called « Electricite de France (EDF). 2006 CATU S.A. BAGNEUX

  2. THE EXPANSION A short time later, a central department for safety and prevention of accidents was created within EDF. Because of the experience that catu had in this field, a very close cooperation was forged between EDF and CATU which resulted in joint development and improvement of all the important safety material and equipment now used in France. 2006 CATU S.A. BAGNEUX

  3. A MEMBER OF THE SICAME GROUP 2006 CATU S.A. BAGNEUX

  4. A FEW REFERENCES FROM AROUND THE WORLD Utililities Industries Railways & transporation Telecoms Firemen Otis Toyota Renault SPIE Alstom Lafarge Siemens Fulmen Total Shell Hyundai SNCF RATP ADP Alstom transport Renfe MTRC KCRC MRT KTM EDF ESKOM Hydro Quebec Electrabel UTE Sonelgaz ONE STEG Adena SEC TNB Energex MEA France telecom Pompiers Paris Bomba (malaysia) 2006 CATU S.A. BAGNEUX

  5. PERSONNEL PROTECTIVE EQUIPMENT (Examples of routine tests) INSULATING GLOVES ARE CONFORM TO IEC & EN 60903 (08/2002) The gloves should be used between -40°C & 55°C Acide, oil, ozone resistance Anti allergic treatment Dielectric test after total immersion in water for a period of 16h. Flame retardancy Tensile strength & elongation at break 2006 CATU S.A. BAGNEUX

  6. PERSONAL PROTECTIVE EQUIPMENT (Examples of routine tests) OVERGLOVES AND WORKING GLOVES ARE CONFORM TO EN 388 Abrasion Perforation Flamme retardancy Tensile strength & elongation at break 2006 CATU S.A. BAGNEUX

  7. IEC 900 « ISOMIL » INSULATED TOOLS 2 Colour insulation -Orange 1000V protection -White visible = Stop and replace tool FOR CORRECT USE OF INSULATED TOOLS ALWAYSWear insulating gloves and eye protection Check insulation sound before using a tool -Never use a tool with insulation that is cracked cut or damaged in any way -Discards tools with insulation that looks unsafe -Don ’t modify insulation -Don ’t let others use your insulated tools -Always use the correct tool -Check standards and approvals markings -Read safety recommendations and keep the instructions Laser marking -Permanent safety data -Tracability 2006 CATU S.A. BAGNEUX

  8. PERSONNEL PROTECTIVE EQUIPMENT IEC 903 INSULATING GLOVES MARKING 00/RC 04 02 CG-05-A 95 LOT:0000 CE 0077 Class 00 500V Class 0 1000V Class 1 7500V Class 2 17000V Class 3 26500V Class 4 36000V 2006 CATU S.A. BAGNEUX

  9. « ISOMIL » INSULATING TOOLS ACCORDING TO IEC 60900 STANDARD Screwdrivers -Pozidriv -Flat blade -Phillips Pliers- Wire Stripping Plier - Bent Snipe Nose Plier - Cable Cutter - Universal Plier - Water pump plier 2006 CATU S.A. BAGNEUX

  10. « ISOMIL » INSULATING TOOLS ACCORDING TO IEC 60900 STANDARD Ratchet cable cutter Socket wrench sets 3/8 ’ ’ & 1/2 ’ ’ Stripping knife Hacksaw Stripping plier for LV cables Insulated torque wrench 2006 CATU S.A. BAGNEUX

  11. « ISOMIL » INSULATED TOOLS Five tests for your safety Individual test to 10,000V at end of manufacturing cycle Impact after chilling to -25°C Non flamability 5000V after penetration test Adhesion after heating to 70°C 2006 CATU S.A. BAGNEUX

  12. THE REASONS FOR CHOOSING CATU 2006 CATU S.A. BAGNEUX