NA62 GTK Cables & Patch Panels

NA62 GTK Cables & Patch Panels. TCC8_GTK1. TCC8_GTK2_GTK3. Rack GTK1-02. Racks GTK1-01 , GTK2-01, GTK2-02, GTK3-01. Cable lengths. 12m. 10,70m. 2,30m. GTK. GTK2. GTK1. GTK3. 4,40m. GTK. GTK. GTK. GTK. cooling. GTK3-01. GTK2-02. GTK1-01. GTK2-01. GTK1: 16,70m GTK2: 7,70m

Download Presentation

NA62 GTK Cables & Patch Panels

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NA62 GTK Cables & Patch Panels

  2. TCC8_GTK1

  3. TCC8_GTK2_GTK3

  4. Rack GTK1-02

  5. Racks GTK1-01 , GTK2-01, GTK2-02, GTK3-01

  6. Cable lengths 12m 10,70m 2,30m GTK GTK2 GTK1 GTK3 4,40m GTK GTK GTK GTK cooling GTK3-01 GTK2-02 GTK1-01 GTK2-01 GTK1: 16,70m GTK2: 7,70m GTK3: 19m

  7. NA62 GTK Electrical Patch panels Patch Panel 1-02 Patch Panel 1-01 1V2 dig (10 cables) GTK_carrier Temp Interlock 1V2 Analog (10 cables) J1 VDDA5-VDDA9 VDDA5-9 senses VDD5-VDD9 VDD5-9 senses P5V +senses VDD5-9 EASY CRATE Analog senses (1 cable) 2V5 3V3 5V 1V2 Dig 1V2 An 5V3 Dig Digital senses (1 cable) 2V5 (1 cable) ~2 meters 3V3 (1 cable) J3 VDDA0-VDDA4 VDDA0-4 senses VDD0-VDD4 VDD0-4 senses P2V5 + senses P3V3 + senses P5V3 (non interlocked) + senses VDD0-4 5V (1 cable) 5V3 (1 cable) One module for three stations temp Temp 1 cable To PLC Bias Bias 1 cable ~4 meters From HV module RACK GTK1-02 RACK GTK1-01 *GTK1

  8. NA62 GTK Patch panels 1V2 Digital CAEN 3009K PS Digital RACK GTK1-01 Patch Panel 1-01 Anderson Connectors 30A ddp= 35mV@ 2A 1.2V Connector CANNON Sub-D 3W3 female 1 connector for each 1V2 Dig = 10 connectors 10 Cables:2.5mm² 0V ~2 m S+ Connector CANNON Sub-D 25 female 1 connector for all Digital Senses 10 x cables AWG28 S- Connecteur AMP 4 pins . Hearth

  9. NA62 GTK Patch panels 1V2 Analog CAEN 3009K PS Analog RACK GTK1-01 Patch Panel 1-01 Anderson Connectors ddp= 40mV@ 0.2A 1.2V Connector CANNON Sub-D 9 female 1 connector for each 1V2 Analog = 10 connectors Cable:0.5mm² 0V ~2 m S+ Connecteur AMP 4 pins Connector CANNON Sub-D 25 female 1 connector for all Analog Senses S- AWG28 . Hearth

  10. NA62 GTK Patch panels 1V2 Digital RACK GTK1-01 RACK GTK1-02 Patch panel 1-01 Patch panel 1-02 A1 = 0V (black) A2 = 1V2 (blue) A3 = shield A1 = 0V (black) A2 = 1V2 (blue) A3 = shield 1.2V Dig 10 Cables:2.5mm² 10 x Connectors CANNON Sub-D 3W3 female 10 x Connectors CANNON Sub-D 3W3 male 0V SCEM: 04.08.82.025.3 1 cable shielded 2x13 twisted pairs S+ 1 x Connector CANNON Sub-D 25 male 1 x Connector CANNON Sub-D 25 female S- SCEM: 04.21.22.726.09 Cables length 9, 18, 20 m

  11. NA62 GTK Patch panels 1V2 Analog RACK GTK1-01 RACK GTK1-02 Patch panel 1-01 Patch panel 1-02 1.2V 10 x Connectors CANNON Sub-D 9 male 10 Cables:0.5mm² 10 x Connectors CANNON Sub-D 9 female 0V SCEM: 04.08.82.025.3 1 cable shielded 2x13 twisted pairs S+ 1 x Connector CANNON Sub-D 25 male 1 x Connector CANNON Sub-D 25 female S- SCEM: 04.21.22.726.09 Cables length 9, 18, 20 m

  12. NA62 GTK Patch panels 2V5 Digital RACK GTK1-01 RACK GTK1-02 Patch panel 1-01 Patch panel 1-02 A1 = 0V (black) A2 = 1V2 (blue) A3 = shield A1 = 0V (black) A2 = 1V2 (blue) A3 = shield 2V5 1 Cable:2.5mm² 1 x Connector CANNON Sub-D 3W3 female 1 x Connector CANNON Sub-D 3W3 male 0V SCEM: 04.08.82.025.3 In the Same Connector CANNON Sub-D 25 male 1V2 dig S+ Senses 2V5 In the same Connector CANNON Sub-D 25 female 1V2 dig S- SCEM: 04.21.22.726.09 Cables length 9, 18, 20 m

  13. NA62 GTK Patch panels 3V3 Digital RACK GTK1-01 RACK GTK1-02 Patch panel 1-01 Patch panel 1-02 A1 = 0V (black) A2 = 1V2 (blue) A3 = shield A1 = 0V (black) A2 = 1V2 (blue) A3 = shield 3V3 1 Cable:2.5mm² 1 x Connector CANNON Sub-D 3W3 female 1 x Connector CANNON Sub-D 3W3 male SCEM: 04.08.82.025.3 0V S+ In the same Connector CANNON Sub-D 25 male 1V2 dig Senses 3V3 In the same Connector CANNON Sub-D 25 female 1V2 dig S- SCEM: 04.21.22.726.09 Cables length 9, 18, 20 m

  14. NA62 GTK Patch panels 5V Digital RACK GTK1-01 RACK GTK1-02 Patch panel 1-01 Patch panel 1-02 A1 = 0V (black) A2 = 1V2 (blue) A3 = shield A1 = 0V (black) A2 = 1V2 (blue) A3 = shield 5V 1 Cable:2.5mm² 1 x Connector CANNON Sub-D 3W3 female 1 x Connector CANNON Sub-D 3W3 male 0V SCEM: 04.08.82.025.3 In the same Connector CANNON Sub-D 25 male 1V2 dig S+ Senses 5V Digital In the same Connector CANNON Sub-D 25 female 1V2 dig S- SCEM: 04.21.22.726.09 Cables length 9, 18, 20 m

  15. NA62 GTK Patch panels 5V3 Digital non interlocked RACK GTK1-01 RACK GTK1-02 Patch panel 1-01 Patch panel 1-02 A1 = 0V (black) A2 = 1V2 (blue) A3 = shield A1 = 0V (black) A2 = 1V2 (blue) A3 = shield 5V3 1 Cable:2.5mm² 1 x Connector CANNON Sub-D 3W3 female 1 x Connector CANNON Sub-D 3W3 male 0V SCEM: 04.08.82.025.3 In the same Connector CANNON Sub-D 25 male analog S+ Senses 5V3 Digital In the same Connector CANNON Sub-D 25 female analog S- SCEM: 04.21.22.726.09 Cables length 9, 18, 20 m

  16. NA62 GTK Patch panels Bias cable RACK GTK1-02 Patch panel 1-02 Mainframe 1 coax cable Connector HV BNC A1821 HV module Rack J06 (surface) Cables length ~230 m

  17. NA62 GTK Patch panels RACK GTK1-02 RACK GTK1-02 Interlock cable Patch panel 1-02 Patch panel 1-02 14 wires :0.12mm² 1 x Connector CANNON Sub-D 15 female Connector CANNON Sub-D 15 male Connectors CANNON D-Sub 15 female Cables length 9, 18, 20 m

  18. NA62 GTK Patch panels RACK GTK1-02 1.2V Dig To GTK carrier J1 Patch panel 1-02 62 pins female 1.2V Dig 11 Cables:1mm² 11 x Connector CANNON Sub-D 3W3 male ddp= 270mV@ 2A 0V ~4 m S + 1 x Connector CANNON Sub-D 25 male Dig senses 11 senses AWG28 S - The shield is left unconnected at the end of the cables 1cable: 1.2VA x 5 1.2VD x 5 5VD x 1 Sense wires: 1.2VA x 5 1.2VD x 5 5VD x 1 Connectors CANNON D-Sub High-Density 62 female Tresse sur 40cm

  19. NA62 GTK Patch panels RACK GTK1-02 1.2V Analog To GTK carrier J1 Patch panel 1-02 62 pins female 11 x Connector CANNON Sub-D 9 male 1.2V 10 Cables:0.25mm² ddp= 108mV@ 0.2A 0V ~4 m S + 1 x Connector CANNON Sub-D 25 male Analog senses 10 senses AWG28 S - The shield is unconnected at the end of the cables Connectors CANNON D-Sub High-Density 62 female Tresse sur 40cm

  20. NA62 GTK Patch panels RACK GTK1-02 To GTK carrier J3 Patch panel 1-02 62 pins female 13 x Connectors CANNON Sub-D 3W3 male 1.2V Dig 13 Cables:1mm² ddp= 270mV@ 2A Cable:0.5mm² 0V ~4 m S+ 1 x Connector CANNON Sub-D 25 male S- 13 senses AWG28 1 cable: 1.2VA x 5 1.2VD x 5 2.5VD x 1 3.3VD x 1 5.3VD x 1 Sense wires: 1.2VA x 5 1.2VD x 5 2.5VD x 1 3.3VD x 1 5VD x 1 Connectors CANNON D-Sub High-Density 62 female Tresse sur 40cm Tresse sur 40cm

  21. NA62 GTK Patch panels RACK GTK1-02 1.2V Analog To GTK carrier J3 Patch panel 1-02 62 pins female 10 x Connector CANNON Sub-D 9 male 1.2V 10 Cables:0.25mm² ddp= 108mV@ 0.2A 0V ~4 m S + 1 x Connector CANNON Sub-D 25 male Analog senses 10 senses AWG28 S - The shield is left unconnected at the end of the cables Connectors CANNON D-Sub High-Density 62 female Tresse sur 40cm Tresse sur 40cm

  22. NA62 GTK Patch panels RACK GTK1-02 Interlock cable To GTK carrier J3 Patch panel 1-02 Sud-D 15 pins female 14 wires :0.12mm² Connector CANNON Sub-D 15 male ~4 m 10 x temp_out (0-9) 1 temp_or 1 gnd 1 vdd_temp 1 shield Connectors CANNON D-Sub 15 female Tresse sur 40cm

  23. Cable GTK1-02 to GTK_carrier J3 1V2 Dig TDCpix 0 1V2 Dig TDCpix 1 1V2 Dig TDCpix 2 1V2 Dig TDCpix 3 1V2 Dig TDCpix 4 J3 2V5 Dig 3V3 Dig 5V3 Dig Digital senses ch 0-4 Analog senses ch 0-4 1V2 Analog TDCpix 0 1V2 Analog TDCpix 1 1V2 Analog TDCpix 2 1V2 Analog TDCpix 3 1V2 Analog TDCpix 4

  24. Cable GTK1-02 to GTK_carrier J1 1V2 Dig TDCpix 5 1V2 Dig TDCpix 6 1V2 Dig TDCpix 7 1V2 Dig TDCpix 8 1V2 Dig TDCpix 9 J1 5V Dig Digital senses ch 5-9 Analog senses ch 5-9 1V2 Analog TDCpix 5 1V2 Analog TDCpix 6 1V2 Analog TDCpix 7 1V2 Analog TDCpix 8 1V2 Analog TDCpix 9

  25. NA62 GTK Patch panels RACK GTK1-02 Bias cable To GTK carrier J3 Patch panel 1-02 1 HV cable ~4 m Lemo connector 100K Connector HV BNC . Connected to the GTK_carrier with a Lemo connector Or with a “Ferrule” Both option on the board

  26. Electrical Patch Panels Mat: Alu antico Quantity: 6 Thickness: 6mm

  27. Cables details Total length: Cable: 2 x 2.5mm²: 705m = 750m ordered Cable: 2 x 0.5mm²: 517m = 550m ordered Cable : 2 x13 AWG28: 94m = 100m ordered Cable : 14 x 0.12mm²: 47m:= 50m ordered + 6 Electrical Patch panels Total Cable Price: 4260CHF

  28. Cable GTK1-02 to GTK_carrier J3 Cable GTK1-02 to GTK_carrier J1

  29. Connectors details Total Price: 2308 CHF

  30. GTK_carrier production

  31. CAEN items

  32. What do we need? • - 3 x EASY CRATES 3000# • 6 x 3009K 3 x Analog and 3 x Digital 1V2 • 1 x 3009K (prototype module) • 3 x 3009 2V5, 3V3, 5V • 1 x 3009 5V3 non interlocked* • 1 A3486 48V power supply • 1 mainframe SY2527: 80CHF/month • 1 branch controller A1676A: 40CHF/m • 1 HV module A1821: 38CHF/m • 1 SY4527: 5862 euros (profitable after 7 years) • 1 A1676A: 1800 euros (profitable 5 years) • 1 A1821: 5260 euros (profitable after 14 years) Bought Rented Bought * 5V3 non interlocked is connected to rad hard voltage regulators which provide VDD_temp (1V2) and temp_logic (3V3) # ALREADY BOUGHT