1 / 29

Combined State Feedback Controller and Observer

Combined State Feedback Controller and Observer. Combined State Feedback Controller and Observer Formulation Separation Principle Transfer Function Representation Combined State Feedback Controller and Reduced Order Observer Illustrative Examples. Motivation.

nanda
Download Presentation

Combined State Feedback Controller and Observer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Combined State Feedback Controller and Observer • Combined State Feedback Controller and Observer Formulation • Separation Principle • Transfer Function Representation • Combined State Feedback Controller and Reduced Order Observer • Illustrative Examples

  2. Motivation • In most control applications all state variables are not measurable • A full or reduced order observer may be used to estimate needed states • Separation principle allows independent controller and observer design

  3. Combined Controller-Observer Formulation Plant: Controller: Observer:

  4. State Feedback Observer Block Diagram u y r System L x y z-1 C H Observer G -K

  5. Closed-Loop System Closed-Loop Control Subsystem: Closed-Loop Observer Subsystem: Overall Closed-Loop System:

  6. Separation Principle Eigenvalues of the closed loop systems are the union of eigenvalues of • Closed-loop poles, i.e., eigenvalues of G-HK and • Observer poles GA-LC

  7. Separation Principle--Transfer Function Closed-Loop System Laplace Transform: Closed-loop transfer function • Closed-loop transfer function is the same as full state feedback • Observer dynamics are canceled

  8. Laplace Domain Representation Plant: Controller: Observer: Laplace Transform of Observer Controller in z-domain:

  9. Transfer Function Block Digaram Representation Control Input: Solving for U gives where Y R G F1 F2

  10. D.C. Motor Example Consider a d.c. servomotor system given by the transfer function y: position output u: input voltage the motor. Motor parameters: k/J=1 and b/J=5.

  11. Feedback Control Design for D.C. Motor Example Desired Closed-Loop System: damping ratio =0.8 and natural frequency n=500 rad/sec (less than 3% maximum overshoot and settling time of 0.01 sec.): System in Controllable Form: Control gain

  12. Servo Example Observer Design Observer Dynamics (2 times faster than controller): =0.8 and n=1000 rad/sec Observer gain: Observer State Equations

  13. Equivalent Transfer Function of Servo Example Feedback and Feedforward Block: where

  14. Closed-Loop Transfer Function R G F1 F2 Pole-zero Cancellation

  15. Combined Controller Reduced Order Observer (CCRO) Plant State Equation: Reduced Order Observer

  16. Transfer Function Representation of CCRO Partition State Feedback Gain: Reduced Order Observer Transfer Function Substitute Z in Control Law: where

  17. Transfer Function Block Digaram Representation of CCRO Y R G F1 F2 F1 and F2 are of order n-q (lower than FOO)

  18. D.C. Motor Example

  19. Closed-Loop System of CCRO Example

  20. Matlab Solution %Simulation Example of Combined Observer %System: G(s)=b/(s^2+bs) % Observable form: dx1/dt=x2, dx2/dt=-ax2+bu %System Matrices b=1; a=5; A=[0 1;0 -a]; B=[0;b]; C=[1 0]; D=0; plant=ss(A,B,C,D);

  21. MATLAB Example Control Design %Control Design %desired closed-loop damping and natural frequency zeta=0.8; wn=500; pd=-zeta*wn+sqrt(zeta^2-1)*wn; %desired closed-loop poles %Ackermans's formula to find gain K=acker(A,B,[pd;conj(pd)]);

  22. MATLAB Example FOO Design %Full-order observer r=2; pdo=-r*zeta*wn+r*sqrt(zeta^2-1)*wn; %desired observer poles L=(acker(A',C',[pdo;conj(pdo)]))'; Ao=A-L*C; ff=ss(Ao,B,K,0); %Part of feedforward block fb=ss(Ao,L,K,0); %Feedback Block g=-(K/Ao)*L;

  23. MATLAB Example ROO Design %Reduced-order observer pr=-r*wn; A11=A(1,1); A12=A(1,2); B1=B(1); A21=A(2,1); A22=A(2,2); B2=B(2); K1=K(1); K2=K(2); Lr=(A22-pr)/A12; Ar=A22-Lr*A12; By=A21-Lr*A11+Ar*Lr; Bu=B2-Lr*B1; ffr=ss(Ar,Bu,K2,0); fbr=ss(Ar,By,K2,K1+K2*Lr); gr=-(K2/Ar)*By+K1+K2*Lr;

  24. Simulink Block Diagram

  25. Simulation Parameters Slow Observers: r=0.5, Fast Observers: r=5 Mismatch: b=1.5 Random input and measurement noise

  26. Slow Observer Plots FOO,ROO

  27. Fast Observer Plots FOO,ROO

  28. Comments on Simulation Results • Slow ROO performs better than slow FOO • High speed ROO and FOO are similar

  29. End of Lecture 18 Next Lecture: Optimal Control