2000 Series Operational Training. Foam Tank. Line Strainer. Check Valves. Flow Meter. Electronic Direct Injection Proportioner. 2000 Series. Water Tank. Multiple Discharges. Water Pump. Discharge Labels.
E N D
Foam Tank Line Strainer Check Valves Flow Meter Electronic DirectInjection Proportioner 2000 Series Water Tank Multiple Discharges Water Pump
Discharge Labels • Discharge handles and/or gauge plates are labeled “FOAM” if they can flow foam.
Digital Display Operation • Digital display reads “Hypro” upon initial power-up • System defaults to “ON” mode when engine is placed into pump • “ON” light illuminates
Digital Display Operation • Open foam discharge • Displays solution volume • “ON” light blinks when foam pump runs • To disarm system push red “FOAM” button • “ON” light turns off • System still functions as flow meter
Water flow in GPM Total gallons of water flowed Foam concentrate injection percentage Total foam concentrate injected Digital Display Information
Digital Display Operation • Water flow display • Push “SELECT” button and total volume of water discharged is displayed • Gallons, liters, imperial gallons
Digital Display Operation • Push “SELECT” button to enter “%” mode • Displays default injection percentage • “PA” Single tank system (“UP” or “DOWN” button will override default setting)
Digital Display Operation • Push “SELECT” button to enter “TOTAL FOAM” • Displays total concentrate injected
Digital Display Operation • Enter “INJECTION PERCENTAGE” from any mode • Press either “UP” or “DOWN” button momentarily to display current percentage setting • Hold either button for two seconds to change setting accordingly
Total Water % Total Foam System Reset Push both buttons while in desired mode to “0” out totals or return to default %
System Reset • Foam Manifold • Release pressure from foam manifold
Low Foam Display • “Lo.Con” display • Selected foam concentrate tank is getting low • Add concentrate within two minutes or… • “no.Con” displays • Concentrate pump shuts off • Add foam concentrate • Push “FOAM” button to restart
Exceeding Foam Injection Rate • “HI.FLO”display • Occurs when water flow exceeds the foam pump capabilities of meeting chosen concentrate injection percentage
Digital Display Operation • Simulated flow • While in “FLOW” mode, push both lower buttons simultaneously • Three bars on left indicate manual mode • Pushing red “FOAM” button will turn foam pump on/off • Pump injects to simulated flow default setting
System Air Purge • Enter “SIMULATED FLOW” • Turn injection valve from “INJECT” to “CAL/FLUSH” • Push red “FOAM” button on display to start foam pump
System Air Purge (cont.) • Run until concentrate flows steady out of dump line • Push red “FOAM” button to stop pump • Turn injection valve to “INJECT” • Exit “SIMULATED FLOW”
Power-fill System • To refill foam tank • Remove Cap • Securely attach pick-up hose to refill inlet • Place pick-up hose into foam container
Power-fill System • To refill foam tank • Turn the refill/flush valve counterclockwise to the stop for the refill position
Power-fill System • Auto fill • Push the “Green” Auto button once. • The pump will start filling the foam tank. • The Green light will flash while the pump is in operation • When the foam tank is full, the Green light is solid and the pump will stop.
Power-fill System • Manual fill • Push and hold “Red” Manual button. • The pump will start filling the foam tank. • The Red light will be solid while the pump is in operation • When the foam tank is full, the Green light will illuminate. • Release Red button
Power-fill System • Flush Operation • Turn the refill/flush valve clockwise to the stop for the flush position. • Place pick-up hose into bucket of clean water.
Power-fill System • Flush Operation • Push and hold “Red” Manual button until discharge fluid from flush drain line is clear. • Release Red button
Daily Checkout • Check foam tank level • Check foam “On-Off” valve is in ON Position. • Check that light under “FLOW” is illuminated and flow meter states “0” when master in on. • Light under ON should be illuminated. Press red button to turn unit OFF. Press again to turn unit back ON.
Weekly Checkout • Inspect wiring, hoses, flow meters and connections for tightness, corrosion, leaks and/or damage. • Check foam pump 30W non-detergent oil level with dipstick or sight level. • Clean foam strainer. • Flow foam concentrate into container checking operation of simulated flow.
Foam pump • Oil level dipstick location
Foam Concentrate Strainer • Close valve in foam concentrate supply line to service strainer
Foam Concentrate Strainer • Locate and remove strainer
Foam Concentrate Strainer • Flush out with clean water • Check gasket • Reinstall • Do not over tighten
Foam Pump Maintenance • Clean top of the foam pump to prevent oil contamination
Foam Pump Maintenance • Remove black dipstick located on top of pump
Foam Pump Maintenance • Check oil level on dipstick or • Check oil level in pump sight glass
Foam Pump Maintenance • Hypro Oil Recommended • Special agents prevent: • Scuff & wear • Moisture • Oxidation • Foaming • Rust • Use 30 wt non-detergent oil in emergency
Semi-Annual Checkout • Remove paddle wheel sensor from foam plumbing and clean with Lime-A-Way or similar cleaner.
Got Foam? (the cliff notes) • Foam • Engage pump • Foam System automatically activates. • Open any discharge labeled “FOAM” • If foam is not desired, press “Red” button on FoamPro Flow meter , system is disarmed. • Refill • Attach pick-up hose and place into container. • Activate refill pump. • Flush system • DO NOT allow refill pump to run without foam or water.