1 / 12

Mercury In Skin Supplies

Mercury In Skin Supplies. By: Abdihakim Abdullahi Chem 4101 December 9, 2011. Background.

nelson
Download Presentation

Mercury In Skin Supplies

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mercury In Skin Supplies By: Abdihakim Abdullahi Chem 4101 December 9, 2011

  2. Background • Mercury in bleaching and cosmetic creams were introduced in the early 1900 when it was discovered that Mercury was extremely effective in lightening dark spots and stubborn pigmentation but it also had a high remission rate. • Nevertheless bleaching creams with high levels of Mercury was aggressively marketed to black people. In 1976 Mercury was banned in the EU when it was discovered that it had damaging side effects. The US banned the use of Mercury in cosmetic creams much later in 1990. • Mercury was banned as it proved to be very toxic and could absorb readily through the skin causing neurological effects.

  3. Problem: Recently more and more products such as Diana and Lemon Herbal Whitening Cream have shown up in the markets, through informal trade, with mercury levels well over the permitted federal limits, of less then one parts per million, of mercury. Some of these products have shown levels at 33,000 parts per million of mercury. Hypothesis: Mercury in said products cause a lot of health issues especially pertaining to communities in which these products keep showing up in.

  4. Experiment Overview • Separation: My analyte, inorganic mercury, is in a very complex matrix (cosmetic cream) so the first thing we have to do is separate the mercury. • Identify: Next we have to identify the mercury, then quantify it. A bottle of mercuric chloride which was classified as a poison.6

  5. Possible Detector techniques

  6. Fluorescence Preferred Detection Method Advantages of Fluorescence: • Highly sensitive technique Up to 1,000 times more sensitive than UV / visible spectroscopy. Therefore often used in drug or drug metabolite determinations by HPLC with fluorimetricdetector. • Selective versatile technique Since excitation and emission wavelengths are utilised, gives selectivity to an assay compared to UV / visible spectroscopy.

  7. Possible Separation Methods

  8. Separation Method of Choice • Reverse phase HPLC coupled to a Hg-specific detector (fluorescence, photometry or other elemental detectors). • Using an eluent of methanol-10 mM sodium acetate buffer (80:20, pH 6.2) containing 0.1 mM 2-mercaptobenzothiazole (MBT). • C18 column, UV detection at 285 nm. • Detection limit for Hg is 0.5 ng Gemini 5µm C18 110A HPLC Mercury Cartridge 10 x 2.0 mm 10/Pk8

  9. HPLC Schematic9

  10. Conclusion • By using analytical methods the mercury in these creams can be quantified then we can find out how toxic/dangerous these creams really are in hopes of finding a correlation to certain health disorders in communities in which these creams are sold. • For my analyses HPLC coupled with a fluorescence detector would yield the best separations due to its high specificity, sensitivity, rapid sample analyses and sufficient detection limit for this problem.

  11. References • Skin-Lightening Products Found to Contain Mercury: Minnesota Department of Health. http://www.health.state.mn.us/topics/skin/ (accessed September 19, 2011) • Lide, D. R., ed (2005). CRC Handbook of Chemistry and Physics (86th ed.). Boca Raton (FL): CRC Press. pp. 4.125-4.126. ISBN 0-8493-0486-5 • Yao-Chin Wang, Chen-Wen Whang: High-performance liquid chromatography of inorganic mercury and organomercury with 2-mercaptobenzothiazole. Department of Chemistry, Tunghai University, Taichung 40704 Taiwan. http://www.sciencedirect.com/science/article/pii/002196739380340E (accessed online, November 7, 2011) • Skoog , D, et al. Principles of Instrumental Analysis, 6th ed.; Brooks/Cole: Belmont, CA, 2007. • Mercury Analysis in Environmental Samples by Cold Vapor Techniques. In: Encyclopedia of Analytical Chemistry. 2006. • Mercury in skin-lightening creams: http://www.startribune.com/lifestyle/wellness/122598954.html • Wells, A.F. (1984) Structural Inorganic Chemistry, Oxford: Clarendon Press. ISBN 0-19-855370-6. • http://www.shimadzu.eu/products/chromato/hplc/modular/default.aspx • http://www.chemistry.adelaide.edu.au/external/soc-rel/content/hplc.htm • ATSDR, Toxicological Profile for Mercury, U.S. Department of Health and Human Services, Atlanta, GA, 1999.; (b) ATSDR, ToxProfiles: Mercury, U.S. Department of Health and Human Services, Atlanta, GA, 2005. • H. Emeteborg, N. Hadgu, D. Baxter, Journal of Analytical Atomic Spectrometry 9, (1994), 297-302. • High-Performance Liquid Chromatography (HPLC): www.files.chem.vt.edu/ chem-ed/sep/lc/hplc.html • Yong-Suk Cho, Kyo Han Ahn, "A ‘turn-on’ fluorescent probe that selectively responds to inorganic mercury species" (Department of Chemistry and Center for Electro-Photo Behaviors in Advance Molecular Systems, POSTECH, San 31 Hyoja-dong, Pohang 790-784, Republic of Korea) http://www.postech.ac.kr/lab/chem/mras/download/90.pdf (Accessed online October 17th, 2011) • Fluorescence Spectroscopy: chemistry.technion.ac.il/download.php?id=119&tbl=equations