1 / 1

OBJECTIVE/BACKGROUND

Development of an Experimental Facility for the Testing of Cadaver Spine Specimens in Flexion and Lateral Bending Design Team : Pratik Sheth, Jason Colgan, Chirag Padalia, Manan Langalia ME 462 – Dr. Hazim El-Mounayri Sponsors – Dr. Alan Jones (ME), Dr. Charles Turner (BME) Spring 2008.

neona
Download Presentation

OBJECTIVE/BACKGROUND

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Development of an Experimental Facility for the Testing of Cadaver Spine Specimens in Flexion and Lateral Bending Design Team: Pratik Sheth, Jason Colgan, Chirag Padalia, Manan Langalia ME 462 – Dr. Hazim El-Mounayri Sponsors – Dr. Alan Jones (ME), Dr. Charles Turner (BME) Spring 2008 DESIGN DESIGN REQUIREMENTS • 2 Separate Modes • Compression/Bending • Pure Bending • Each mode has different upper mount • Force measured at the piston on MTS Machine • Loads variable during compression/ bending OBJECTIVE/BACKGROUND • Device must attach to the MTS 810 Test Frame • Generate pure bending • Allow for compression and bending • Adaptable to different sizes of spine • Easy to assemble & attach to spine • Easy to use • Minimal frictional effects • Reasonable Cost • Spine injuries are commonly fixed with unique combinations of fasteners and hardware developed by the neurosurgeons. • No method to test spinal attachments under bending loads • This limits in determining the best combination for the spinal implants. • As a result, there is a need for developing a procedure which would help fixing the problem. • The main goal is to develop a testing platform which would help achieve pure bending and evaluate new implant designs for spinal injuries. • The testing platform should attach with the MTS 810 machine available on campus. SPINE TESTING PLATFORM Figure 2. Design for Compression/Bending Mode (Model w/ the Exploded View) Figure 3. Design for Pure Bending Mode (Model w/ the Exploded View) COST & CUSTOMER TESTING/VALIDATION • No standardize equipments available for testing corrective spinal attachments. • Cost should not exceed $5000 • Our customers are IU School of Neurosurgery, Dr. Charles Turner, and Dr. Alan Jones. • Von Mises Stress Analysis Performed on the critical parts. CONCLUSION • Testing Platform attaches to MTS 810 • Design for both the modes allows testing of spine specimens to study various load conditions • Critical parts of the design meet stress requirements RECOMMENDATIONS • Build a prototype to test the design • Perform the necessary tests to improve the testing platform to meet the design & cost requirements Figure 4. Stress Analysis on Critical Parts Figure 1. MTS 810

More Related