10 likes | 113 Views
RUL4 (left IP4) NC. 1 internal missing resistor Additional external resistor. . Never quenched 1 Trip at 420 A (no quench) Operate at 400A. Ramp Up/Down 0.2 A/s. RUR4 (Right IP4) NC. None .3 training quenches in 2008 (422, 445, 450 A) never quenched in 2010. Operate at 400A.
E N D
RUL4 (left IP4) NC. 1 internal missing resistor Additional external resistor. . Never quenched 1 Trip at 420 A (no quench) Operate at 400A. Ramp Up/Down 0.2 A/s RUR4 (Right IP4) NC. None .3 training quenches in 2008 (422, 445, 450 A) never quenched in 2010. Operate at 400A. Ramp Up/Down 0.08 A/s Undulators status Dear all, Friday 3/5/2010 After discussing with Reiner and Rudiger, it seems that none of the trips of this magnet was a quench. There is a problem with the DCCT measure that creates a fake DIDT and a fake U_res. Reiner is going to disable the inductive correction in the algorithm and implemented as soon as possible. That will mean that we have to ramp slowly, probably even slower than now, to avoid a trip. In any case, this will be self-regulating. I put a comment on the first entry of todays logbook. Nuria R.M. ESLM 22 March 2010