1 / 26

Corrosion Management on Pipeline with Cathodic Protection

Corrosion Management on Pipeline with Cathodic Protection. Ilmu Bahan dan Korosi. Outline. Pipeline Risks and Corrosion Cp Technique : Galvanic Sacrificial Anode ( Principle , Installation ) Cp Technique : Impressed Current ( Principle , Installation )

nessa
Download Presentation

Corrosion Management on Pipeline with Cathodic Protection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Corrosion Management on Pipeline with Cathodic Protection Ilmu Bahan dan Korosi

  2. Outline • Pipeline Risks and Corrosion • Cp Technique : Galvanic Sacrificial Anode (Principle, Installation) • Cp Technique : Impressed Current (Principle, Installation) • Case Study : Sacrificial Anode • Case Study : Impressed Current

  3. Risks on Pipeline The product of the frequency with which an event is anticipated to occur and the consequence of the event outcome. RISK = PROBABILITY x SEVERITY

  4. Risks on Pipeline PRESSURE DROP LEAKAGE CORROSION

  5. Corrosion Control • Coating : insulation • Cathodic Protection: DC current injection towards pipeline, result: pipeline is “shifted” as cathode. • Sacrificial anode • Impressed current

  6. Galvanic Sacrificial Anode - Principle • Metal Driving voltage (Vd) • Negative Vd = active metal =tendency to corrode • Pipeline: connected with active metal • Anode: Mg, Zn Cathode: pipeline • Corrosion on Mg, Zn hence “sacrificial”

  7. Galvanic Sacrificial Anode-Principle

  8. Galvanic Sacrificial Anode-Installation (Source: Peabody’s Control of Pipeline Corrosion)

  9. Galvanic Sacrificial Anode-Installation (Source: Peabody’s Control of Pipeline Corrosion)

  10. Impressed Current • Minimum potential: -0.85V • Reference electrode: Copper Sulfate (Source: Peabody’s Control of Pipeline Corrosion)

  11. Galvanic Sacrificial Anode-Design • Calculate total area to be protected (Ap) • Determine the current density (ρ) • Calculate total protection current (Itot = ρ .Ap) • Calculate R per anode : R = f(d,l,ρ) • Calculate Ia per anode : (Vd-0.85/R) • Calculate total anode needed : • Initial : N=Itot/In • Lifetime: N = f(mass,lifetime,A/poundyear)

  12. Impressed Current-Principle • Rectifier • Variable voltage, variable current • Higher current density (> 1 A) • Higher soil resistivity (> 104 Ωcm)

  13. Impressed Current-Installation • Types of anode: • Graphite : big CR (pound/A/year) • High Silicon Cast Iron : medium CR • Platinum & niobium : small CR • Rectifier rating: • Voltage, Amperes, Watt, Freq. • Cooling System : Air, Oil • Efficiency CR: Consumption Rate

  14. Impressed Current - Installation (Source: Peabody’s Control of Pipeline Corrosion)

  15. Impressed Current - Design • Calculate total area to be protected (Ap) • Determine curent density (ρ) • Calculate total protection current (Ip) • Calculate total anode needed (N) • Initial • Lifetime • Calculate total anode resistance (Rtot = f(N,ρ,d,L,spacing)) • Calculate rectifier specification (Vdc, Idc, Pdc = f(Rtot,Ip)

  16. Pipeline Cathodic Protection– Case Study

  17. Galvanic Sacrificial Anode – Case Study

  18. Galvanic Sacrificial Anode – Case Study • Step 1: surface area of pipeline • Step 2: total protection area • Step 3: total protection current

  19. Galvanic Sacrificial Anode – Case Study • Step 4: Anode resistance (Dwight’s Equation) • Step 5: Current per Anode

  20. Galvanic Sacrificial Anode – Case Study • Step 6: Total Number of Anode • Initial • Lifetime Selected number of anodes: 31.

  21. Galvanic Sacrificial Anode – Case Study • Step 7: Distribution and Layout • Distribution • Layout

  22. Impressed Current Case Study

  23. Impressed Current Case Study • Step 1: surface area of pipeline • Step 2: total protection area • Step 3: total protection current • Step 4: determine type of anodes Iron Silicon Chromium. Weight: 110 pon, cross section 4 sqft (0,371m2), diameter 10 inch (0,833 feet = 2,54cm), length 84 inchi (7 feet = 20,32cm)

  24. Impressed Current Case Study • Step 5: total number of anodes • Current limit (silicon: 10.76 A/m2) • Lifetime Total anodes: 4.

  25. Impressed Current –Case Study • Step 6: groundbed resistance calculation Resistance limit: 2Ω (to limit rectifier’s spec) Spacing: S = 30 feet , Anode Length: L = 7 feet Anode Diameter: D = 0.8333 feet Groundbed resistance is below limit. If not, choose longer spacing.

  26. Impressed Current - Principle • Step 7: rectifier specification Specification: 21VDC, 302W . Final Results: • Anodes : Iron Silicon Chromium, 4 anodes. • Rectifier : 21VDC, 302W.