1 / 3

DT Muons: Offline Analysis

DT Muons: Offline Analysis. Package of analysis started from the DQM modules and developed further. more info on trigger (correlation between sectors, efficiency for specified trigger configuration e.g. HH&HL ). fit t0 track by track (reconstruction without calibration).

Download Presentation

DT Muons: Offline Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DT Muons: Offline Analysis • Package of analysis started from the DQM modules and developed further • more info on trigger (correlation between sectors, efficiency for specified trigger configuration e.g. HH&HL ) • fit t0 track by track (reconstruction without calibration) • alignment analysis with tracks • full StandAlone muon reconstruction • Not yet committed, to be decided where to put it in CMSSW (new dedicated package?) • Used always on real data • massively used at the Commissioning • Inside the calibration package we have also monitoring tools related with the detector calibration: • tools for histogramming and visualize our calibration constants • module to check the detector behavior in “test pulse” runs and “noise” runs (dedicated runs for calibration) • Used on real and simulated (when possible) data • massively used at the Commissioning • started to be used on simulated data for the CSA07 S. Bolognesi

  2. DT Muons: Validation suite • CMSSW package (Validation/DTRecHits) to validate the calibration/reconstruction of the data • residuals, pulls and efficiency for all the steps of the local reconstruction • Used always on simulated data (it access the simulation information) • used to validate the local reconstruction in each new CMSSW release • used to validate the calibration constants for CSA07 S. Bolognesi

  3. DT Muons: Monitoring VS Analysis Issue still to be addressed in full details in the DPG Monitoring • a subset of the DQM plots (trigger, digi, reco info) can be selected remaking them with bigger statistics and more precise alignment/calibration • adding also further development of • calibration/alignment validation plots • dedicated analysis for calibration runs (noise, test pulse) Offline analysis • the present offline analysis package can be further automatized, cleaned (and committed), extended with • additional analysis of higher level variables • scaling with full CMS detector (more DT sectors at once, matching with other subdetectors info) S. Bolognesi

More Related