An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Simple Texture Devices

  2. Puncture Testers/Penetrometers • Devices used to measure the force required for a probe to penetrate the food • Magness Taylor “Pressure testers” • UC Fruit Firmness testers • Ballauf, Chatillon, Effi-Gi • Maximum force is measured at which material yields (the material gives and exhibits irreversible damage)

  3. Dial stays at maximum force reached • Firmness of fruits related to ripeness or process • Firmness of vegetables due to maturity or processing

  4. Probes may be attached to TXAT2 or Instron

  5. The force changes in different ways after penetration A: Force increases after yield point B: Force levels off after yield point C: Force decreases after yield point D: Gradual increase in force after yield point E: Increasing force; no yield point observed

  6. The distribution in stress before puncture is uneven over the area of the probe

  7. The force-distance curves are determined both by compression and shearing

  8. Force on the punch is given by • F = KcA + KsP + C • where Kc is the compression coefficient (N mm-2), A the area of the punch (mm2), Ks is the shear coefficient (N mm-1), P is the perimeter of the punch (mm), and C is a constant. Note!! The skin greatly influences the results Typically it is first removed.

  9. Cone Penetrometer • Measure firmness/yield point of butter, margarines, solid fats • Allow cone to fall into sample by gravity after specific time (e.g. 5 secs)

  10. For fats, Haighton (1959) showed that the yield value C is related to the weight of the cone (W), the penetration depth (P), and a cone constant (K): • Dixon and Parekh (1979) describe butter firmness by:

  11. Distance Measuring Devices • Bostwick Consistometer • consistency of applesauce, catsup, baby food, carrot puree • distance (in cm) sample travels in 30 sec

  12. For curved surface, measure front edge 24 23 22 21 20 1 1 1 1 1 1 1 Ignore clear separated liquid

  13. Hilker-Guthrie Plummet: consistency of cream, yogurt. Graduated scale measures how for it Penetrates (read after 5 s)

  14. For cultured cream Very thin 0 - 2 Thin 2 - 4 Medium 4 - 6 Good 6 - 7.5 Slightly heavy 7.5 - 8.5 Heavy 8.5 - 10 Very heavy > 10

  15. Ridgelimeter: measures rigidity of pectin jellies • Jelly mad in proscribed conditions • At 24 hrs inverted on stage • Pointer tip lowered and zeroed true grade = assumed grade (2.0 - %sag/23.5)

  16. Ball Indenter: test hardness of fats and waxes

  17. Brinell Tester

  18. Haugh Meter: used to measure egg quality. Thick yolks that do not run indicate fresh, high quality eggs.

  19. Weigh egg, break shell • Spread on glass plate • Put center pin ~10 mm from edge of yolk • Turn to just touch albumen

  20. One measure of egg quality • Grade AA or Fancy Haugh units > 72 • Grade A Haugh units > 60

  21. USDA Consistometer: sample of defined dimensions placed in center of sheet containing concentric circles. • Distance of flow in 4 quadrants measured after 1 minute • Consistency of applesauce

  22. Take average of 4 quadrants

  23. USDA grades for apple sauce • Grade A Regular Flow < 6.5 cm • Grade A Chunky Flow < 7.5 cm • Grade B Regular Flow < 8.5 cm • Grade B Chunky Flow < 9.5 cm