1 / 10

Gd Liquid scintillator: completion of the R&D!

Gd Liquid scintillator: completion of the R&D!. LENS R&D  new metal β -diketone molecule (MPIK) Stable: 0.1% Gd-Acac (few months) Baseline receipie ~80% mineral oil + ~20% PXE + Fluors + wavelenght shifters In-loaded scintillators (0.1 %, 5% loading) are counting @Gran Sasso

ninon
Download Presentation

Gd Liquid scintillator: completion of the R&D!

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gd Liquid scintillator: completion of the R&D! • LENS R&D  new metal β-diketone molecule (MPIK) • Stable: 0.1% Gd-Acac (few months) • Baseline receipie ~80% mineral oil + ~20% PXE + Fluors + wavelenght shifters • In-loaded scintillators (0.1 %, 5% loading) are counting @Gran Sasso • Spare stable receipies available (MPIK, INFN/LNGS) Stability 0,1 % Gd in PXE 3+Gd Gd-Acac molecule • Completion of the R&D first half of 2004 • Choice of the final scintillator • Stability & Material compatibility  Aging tests (MPIK, Saclay)

  2. Gd Liquid scintillator tests in Saclay • Goal: 1/ Test the LONG term stability of the scintillator 2/ Test the material compatibility with acrylic, glue, ...  Towards the desgin of the acrylic vessels • Tight stainless steel boxes flushed with N2 – 20- 130cl quartz cuvettes • Aeging test  scintillator temperature ~50 degrees • Systematic periodic photospectrometer absorbance measurements

  3. Acrylic vessels Gamma catcher Target Final assembly (in several part) In Chooz’s site Assembly in the manufacturer workshop 3.6m 2.4m 4m 2.8m 2m Thickness = 6mm

  4. Stress in acrylic vessels • Suspension: 3 points at 120 degrees • Thickness: 6 mm • Empty weight: • Target = 220kg • Gamma catcher = 470kg  Maximum stress: 12 MPa Target Gamma catcher DAPNIA/SIS/LCAP - JMB

  5. Filling of vessels: • Dosing pums (diaphragm pumps or peristaltic pumps): accuracy ~1% • Pump + electronic flowmeter: accuracy ~0.5% • Weight & density measurements • Density: accuracy 0.001 g/cm3 (can reach 0.0001 g/cm3) • Weigth: accuracy <10 kg on ~12 tons. • ->volume ~0.1%

  6. Full detector simulationPCC & APC, Kurchatov

  7. Parameters used for the simulation Reactor thermal power: 8.4 GW Near detector distance: 150 meters Volume N & F: 12.67 m3 Far detector distance: 1050 meters with PXE => 12.5 tons Near detector efficiency: 32 % 50 % dead time x 80 % global load factor x 80 % detection Far detector efficiency: 64 % No dead time x 80 % global load factor x 80 % detection “Standard systematic errors”: absolute 1 par fit relative backgrounds or with

  8. Sensitivity at 90% C.L. if sin2(213)=0 versus integrated luminosity in RNU σabs =2% σrel =0.6% σshape =2% σb2b =1% New target composition increases luminosity by 30 % Reactor 1 (2 RNU) Reactor 2 (40 RNU) 1 RNU = 200 t.GW.y

  9. Summary & outlook @Double-CHOOZ • Support for the EDF power company to do a 2nd experiment @CHOOZ Double-CHOOZ sensitivity: sin2(213)<~0.03, 90% C.L. (m2 = 2.0 10-3 eV2) Current limint: CHOOZ : sin2(213)<0.2  discovery potential ! • Technology / design well known (CHOOZ, BOREXINO, KamLAND, …)  few R&D needed : Gd loading (stability) + material compatibility (Started, to be completed in half a year) • Proto-collaboration: PCC, Saclay, APC, TUM, MPIK, Tubingen, Kurchatov, Italy (likely to grow during the winter)  (maxi-)letter of intent (February 2004)  final proposal (6 months) • Experiment cost, Double-CHOOZ case: 2 x ~13 tons, preliminary detector cost <10 Meuros (Civil engineering not included) • Our Goal @Double- CHOOZ: Construction starts end of 2005 Start data taking in 2007-2008 2004 2005 2006 2007 2008 2009 2003 Site Prop. design Construction ? Data taking Far detector starts < sin2(213) < 0.025-003 < sin2(213) < ~0.04

More Related