1 / 15

The World’s first robotic, LED based , smear microscope for TB screening!

The World’s first robotic, LED based , smear microscope for TB screening!. The Tireless Technician!. Facts about the TB burden. With 8.8 Mi new cases annually and almost 1,5 Mi deaths, TB is still a leading mortality factor TB is the leading killer of people with HIV

nira
Download Presentation

The World’s first robotic, LED based , smear microscope for TB screening!

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The World’s firstrobotic, LED based, smear microscopefor TB screening! The Tireless Technician!

  2. Facts about the TB burden With 8.8 Mi new cases annually and almost 1,5 Mi deaths, TB is still a leading mortality factor TB is the leading killer of people with HIV 22 HBC (High Burden Country) countries account for 80% of the incidence Annually over USD 1 Bi was spent on TB diagnostics in 2009, and the sum is increasing TB drains 12 billion USD from the annual incomes of the poorest communities Loss of productivity attributable to TB approaches 7% of GDP in some countries In 2009 there were 9,7 million orphan children a a result of TB deaths Nearly 4,000 people die from TB daily, a curable disease in most cases !! Source WHO

  3. Further Facts The most commonly used sputum smear microscopy is more than 100 years old, but is the most affordable for the majority of HBC countries Traditionally executed, it is also the most ineffective, detects only little more then half of patients tested with currently used manual method, mainly due to low sensitivity, lack of well trained personel, tiring factor. Todays TB drugs are more then 40 years old and have to be taken for 6-9 months Todays TB vaccine is more than 85 years old Delay in assessing proper diagnostics costs time, money and leads to continued transmission of infectionsThere is huge need for tools that correspond to the medical need at affordable price (WHO report) There is urgent need for more accurate and rapid diagnostic tests (WHO, FIND) Source WHO

  4. TB Burden in 2009 Source WHO

  5. TB Diagnostics market in 2009 Source WHO

  6. Light source microscopy ZN staining The fastest and cheapest available method Good specificity Weak sensitivity Trained staff needed Time consuming,10– 15 min./slide Traditional Fluorescencemicroscopy Increased sensitivity More expensive Faster, less tiresome Maintenance requirements (mercury vapour lamps) Sputum smear diagnosis of TB:

  7. The smear market in 2009 Source WHO

  8. The Global Revised WHO Plan 2011-2015

  9. Microscopy market in 2009 Source WHO

  10. Market cont. • Current assumptions: • Number of microscopy centers was ~70K (58K public, 12K private) in 2009 • 1 smear laboratory/ 100 000 population should be reached by 2015 (WHO) • 20% of microscopes should be replaced by LED by 2015 (WHO) - Potential smear market 200 M tests (WHO) Source WHO

  11. Fluorobot: the only fully automated, dedicated solution • Based on the traditional smear microscopy principle • Fully automated • Input / output and moving of the slides • Image capturing and analysis • Intelligent bacterium recognition algorythms • Low cost, robust design suitable for high incidence, high burden countires • Huge walk away window, batch processing of 100 – 250 slides • Small footprint • High throughput (25 smears/hour) • Competitive cost/test

  12. Main Features • Illumination system using LED technology, much less sensitive, longer lifetime and cheaper than mercury vapour lamps • Robust, cost effective X-Y movement • Special, fast focusing system • Cost effective, simplified light path, optimised for a single magnification • Dedicated image processing and pattern recognition algorithms used for bacteria identification • Classification follows WHO reccomendation (neg., scanty, +, ++, +++) • Standardised quality, no tiring effect • Images are stored, can be transmitted, archived, revisited • Opening new Quality Control possibilities • No trained microscope reading staff needed

  13. Major milestones • Feasibility Study in Q1 2009 • Functional Model stage was successfully reached Q4 2009 • Laboratory Sample Stage was reached at Q3 2010 • „Proof Of Principle” study was conducted at German TB Reference Laboratory, WHO Supranational Laboratory at Borstel led by Dr. Rüsch-Gerdes in September 2010, with positive outcome • „Letter Of Intent” was signed with FIND (Foundation for Innovative New Diagnostics, Geneva) in November 2010 • Project was exhibited at MEDICA 2012 Dusseldorf and Medical Fair India 2013 in New Delhi, with huge success • Strategic Partner is searched, to carry the project through Prototype Development (Q3 2013) and Validation (Q4 2013) • Industrialization and Test Production Planned Q3 2014 • GoLive of final product (and disposable) planned Q4 2014

  14. The Road behind our development team • Core team has more than 15 years experience in medical imaging and robotic microscopy • Main project in the early 90s was the Seditron urine sediment analyzer developed and produced for Boehringer Mannheim

  15. Your Invitation! Join the Journey!

More Related