Electronics for first beam tests of diamond sensors

Electronics for first beam tests of diamond sensors. Presented by: Igor Emeliantchik. Current Status of Diamond Sensors Research. Laboratory tests with 90 Sr: Charge collection efficiency of 20%. Next step: first prototype for beam tests. Beam tests planned: PITZ ate first, then

niveditha
Download Presentation

Electronics for first beam tests of diamond sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electronics for first beam tests of diamond sensors Presented by: Igor Emeliantchik

  2. Current Status of Diamond Sensors Research Laboratory tests with 90Sr: Charge collection efficiency of 20% Next step: first prototype for beam tests Beam tests planned: PITZ ate first, then CERN, HERA, TTF2 Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  3. What should we expect at PITZ? 5MeV Typical spectrum of x-ray tube. Something similar can be expected at sensor location Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  4. Diamond Sensor and g-quanta Probability of photon interaction within 300 mm of diamond sensor Calculations are based on data compiled by W. H.McMaster et. al. Compilation of X-ray Cross-Sections, National Bureau of Standards, for calculation of x-ray cross sections, http://www.csrri.iit.edu/periodic-table.html Photons with energies of several keV are expected to give main contribution. 13 eV are needed for 1 e-hole production. Thus 1 photon will give about 100e. So, if PITZ halo contains a dozen or more photons with energy of several keV per bunch, we have a chance to register it with our diamond sensor Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  5. Time Structure of the Beam at PITZ So, we need fast electronics, able to operate at 100ns bunch rate with minimum noise Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  6. Metallized plastic box Rfb Cfb Diamond CSP “Tetrod” OpAmp AD829 Output Ccal 50 Test Readout Electronics for Beam Tests of Diamond Sensors Charge-sensitive preamplifier “Tetrod” is a low-noise one-channel monolythic IC, developed at NC PHEP (Minsk), and produced by microelectronics plant “Integral” (Minsk) Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  7. Two Types of “Tetrod” Preamplifier IC Tetrod-JFET preamplifier Tetrod-BJT preamplifier Tetrod preamplifiers were designed for calorimetric applications, so they have big dynamic range, at least 13 bits Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  8. Tetrod-BJT amplifier Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  9. Oscillograms of Tetrod-BJT Amplifier Preamp output 20ns/div Shaper output 20ns/div Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  10. Performance of Tetrod-BJT Amplifier Noise Linearity Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  11. Performance of Tetrod-jFET amplifier Noise Linearity Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004

  12. Conclusions Two amplifiers, Tetrod-BJT and Tetrod-jFET are designed, produced, and tested. Tetrod-jFET has slightly better noise performance. Tetrod-BJT is faster Both amplifiers seem to be suitable for beam tests Instrumentation of the Forward Region for a Linear Collider Detector Prague, April 15 - 17, 2004