1 / 25

SLAC E-165

SLAC E-165. Fl uorescence from A ir in Sh owers ( FLASH ) J. Belz 1 , Z. Cao 2 , P. Chen 3* , C. Field 3 , P. Huentemeyer 2 , W-Y. P. Hwang 4 , R. Iverson 3 , C.C.H. Jui 2 , T. Kamae 3 , G.-L. Lin 4 , E.C. Loh 2 , K. Martens 2 , J.N. Matthews 2 , W.R. Nelson 3 , J.S.T. Ng 3 ,

odeda
Download Presentation

SLAC E-165

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SLAC E-165 Fluorescence from Air in Showers (FLASH) J. Belz1, Z. Cao2, P. Chen3*, C. Field3, P. Huentemeyer2, W-Y. P. Hwang4, R. Iverson3, C.C.H. Jui2, T. Kamae3, G.-L. Lin4, E.C. Loh2, K. Martens2, J.N. Matthews2, W.R. Nelson3, J.S.T. Ng3, A. Odian3, K. Reil3, J.D. Smith2, P. Sokolsky2*, R.W. Springer2, S.B. Thomas2, G.B. Thomson5, D. Walz3 1University of Montana, Missoula, Montana 2University of Utah, Salt Lake City, Utah 3Stanford Linear Accelerator Center, Stanford University, CA 4Center for Cosmology and Particle Astrophysics (CosPA), Taiwan 5Rutgers University, Piscataway, New Jersey * Collaboration Spokespersons

  2. MOTIVATIONS • Discrepancy in the UHECR spectrum • Future experiments: Auger, OWL, EUSO, etc. AGASA HiRes

  3. FLUORESCENCE ISSUES • Detailed shape of the fluorescence spectrum • Photon scattering during propagation sensitive to wavelength • Fluorescence spectrum exhibits structures on the order of 10nm • Pressure dependence of the fluorescence yield • Detailed exploration below 100 torr (or above 15 km) important to space-based detectors such as EUSO and OWL • Effects of impurities on fluorescence yield • Impurity composition, e.g., CO2, Ar and H2O, above 20 km is neither stable nor well known. • There may even be surprises in the fluorescence yield at high altitude • Effects of electron energy distribution on yield • A significant fraction of energy in an EAS is carried by energy <1 MeV • Fluorescence efficiency inthis energy range is poorly known

  4. MEASURING FLUORESCENCE AT SLAC • Extensive Air Showers (EAS)are predominantly a superposition of EM sub-showers. • Important N2 transition (2P) not accessible by proton excitation; only e-beam can do it. • FFTB beam-line provides energy equivalent showers from ~1015 to ~1020 eV. • 108-1010 electrons/pulse at 28.5 GeV. • 2% of electron pulse bremsstrahlung option.

  5. OBJECTIVES • Spectrally resolved measurement of fluorescence yield to better than 10%. • Investigate effects of electron energy. • Study effects of atmospheric impurities. • Observe showering of electron pulses in air equivalent substance (Al2O3) with energy equivalents around 1018 eV.

  6. PROGRAM • Gas Composition • N2/O2 dependence, and Ar, CO2, H2O impurities • Pressure Dependence • Yield versus Pressure down to 10 torr • Energy Dependence • Yield versus electron energy distribution down to 100keV • Fluorescence Spectrum • Resolve individual bands using narrow band filters or spectrometer. • Pulse Width • Pressure dependence of fluorescence decay time for each spectral band

  7. THIN TARGET STAGE • Pass electron beam through a thin-windowed air chamber. • Measure the total fluorescence yield in air. • Measure the yield over wide range of pressures at and below atmospheric. • Measure emission spectrum using narrow band filters or spectrometer. • Effects of N2 concentration. Pure N2 to air. Also H2O, CO2, Ar, etc.

  8. THICK TARGET STAGE • Pass electron beam through varying amounts of showering material (Al2O3). • Is fluorescence proportional to dE/dx? • What are the contributions of low-energy (<1 MeV) electrons? • Can existing shower models (EGS, GEANT, CORSIKA) correctly predict fluorescence light? • How does the fluorescence yield in an air shower track the shower development?

  9. THICK TARGET SHOWER DEVELOPMENT

  10. BREMSSTRAHLUNG BEAM OPTION

  11. CORSIKA AIR SHOWERS

  12. SYSTEMATIC UNCERTAINTIES • Defining the yield as Y = n /(x ne) • n Number of photons • x Distance of travel • ne  Number of e– (and e+) • We intend to measure Y and dY/d to better than 10%.

  13. SYSTEMATIC UNCERTAINTIES • Beam charge should be measurable by the beam toroids to better than 2%. • When showering the beam, the beam energy will also affect the number of particles in the shower. This should be determined to better than 0.5%. • If a bremsstrahlung beam is used the contribution of the converter foil thickness uncertainty should be less than 1%.

  14. SYSTEMATIC UNCERTAINTIES • The uncertainties in showering 3%. • Uncertainty in simulations and transition effects from dense target to air 2%. • Uncertainty in amount of showering material of 1-1.5%.

  15. SYSTEMATIC UNCERTAINTIES • Detector systematic uncertainties of 5.4%. • PMT calibration uncertainty of 5%. • Cable and ADC uncertainty of 2%. • Detector Optics 4% (thin) 6.5 % (thick). • Wide band filters and mirrors (1%). • Narrow band filter transmission (3%).

  16. SYSTEMATIC UNCERTAINTIES • Beam charge should be measurable by the beam toroids to better than 2%. • The uncertainties in showering 3%. • Detector systematic uncertainties of 5.4%. • Detector Optics 4% (thin) 6.5 % (thick). • Total systematic uncertainty of 7-9%.

  17. SYSTEMATIC UNCERTAINTIES

  18. THIN TARGET SETUP • Thin target stage requires the 28.5 GeV beam to deliver 108-109 e- per pulse. • Located in the FFTB tunnel.

  19. THIN TARGET AIR CHAMBER LEDs LED PMT PMTs

  20. THICK TARGET SETUP • Thick target stage requires the 28.5 GeV beam to deliver 107-108e- per pulse. • Alternatively, the FFTB bremsstrahlung beam can be used to select 2% of a larger pulse beam. • The layers of Al2O3must be remotely moveable to allow changing of shower depth observed.

  21. THICK TARGET SHOWER WIDTH

  22. THICK TARGET SETUP

  23. E-165 PLAN SUMMARY • Thin Target • Pressure variations • Fluorescence Spectrum • Linearity of fluorescence with beam charge. • Impurities.

  24. E-165 PLAN SUMMARY • Thick Target • Shower depth variations. • N2/O2 variations. • Fluorescence spectrum.

  25. CONCLUSION • FLASH aims to achieve an accuracy of 10% in the total fluorescence yield and individual spectral lines. • Verify energy dependence of yield down to ~100keV. • Both thin target and thick target approaches will be invoked. • Dependence of yield and spectrum on pressure and atmospheric impurities will be measured. • Shower developments equivalent to ~1018 eV will be measured at various depths and compared with codes. • We hope that FLASH will help to shed light on the apparent differences between HiRes and AGASA, and provide reliable information for future fluorescence-based UHECR experiments.