1 / 6

SVD2.0 irradiation

SVD2.0 irradiation. Shun Ono (Tokyo tech). 内容. SVD の H.V. を 0 ~ 100V まで変化させ、各ハイブリッドごとに流れる電流を測定 60,70,80,90,100V で local run を取る 現在 γ 線の照射実験をしている DSSD test sample の測定値との比較. Leakage current of test sample DSSD. DSSD test sample の current のバイアス依存性 Co60 のガンマ線を 1krad/hour の割合で照射

ophira
Download Presentation

SVD2.0 irradiation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SVD2.0 irradiation Shun Ono (Tokyo tech)

  2. 内容 • SVDのH.V.を0~100Vまで変化させ、各ハイブリッドごとに流れる電流を測定 • 60,70,80,90,100Vでlocal runを取る • 現在γ線の照射実験をしているDSSD test sampleの測定値との比較

  3. Leakage current of test sample DSSD • DSSD test sampleのcurrentのバイアス依存性 • Co60のガンマ線を1krad/hourの割合で照射 • H.Vを上げていくと完全に空乏化した時点で、trapされたholeによるcurrentの増加 • 200kradでは80Vで空乏化が終わっていない?

  4. leakage current of SVD • Bias dependence of Current of each hybrid • 40~60Vでcurrent量が増加 Current [mA] Current [mA] H.V [V] H.V [V] First layer Hybrid: H0,H1 Second layer Hybrid: H30,H31

  5. Noise量の変化 • 各ハイブリッドごとの平均noise量(512chの平均)の変化 • 60~70Vで大きく減少 • 全体的にn側のほうがp側よりも大きい First layer Hybrid: H0,H1 Second layer Hybrid: H30,H31

  6. Summary • Test sampleと同様trapされたholeによるcurrentの増加が見られる。ただし、40~60Vでおきているので空乏化は完了しているようである。 • Noiseは全体的に60~70Vで減少している。 • Bias電圧80Vは適正と見てよいと思われる。 • ただしleakage currentは照射サンプルと比較してかなり大きい。(test sample 5.7mA, SVD 24mA) • 空乏化が完了する電圧もずれている。 • γ線以外の影響?

More Related