Parani-MSP1000 Firmware Upgrade v1.2.0 Notes. 2008-05-20 Sena Technologies. Contents. New Features Repeater mode Serial Hub mode Vertex mode Control Commands Others Serial modem card support VFAT support Enhanced handling of Bluetooth FTP RFC2217 support Bug Fix List. Repeater Mode.
E N D
Parani-MSP1000 Firmware Upgrade v1.2.0 Notes 2008-05-20 Sena Technologies
Contents • New Features • Repeater mode • Serial Hub mode • Vertex mode • Control Commands • Others • Serial modem card support • VFAT support • Enhanced handling of Bluetooth FTP • RFC2217 support • Bug Fix List
Repeater Mode • New mode added to the list of Operation mode • Menu: Bluetooth -> Operation Mode • Parani-MSP1000 in Repeater mode can be used to function as a Repeater in order to extend the range of Bluetooth transmission or avoid obstacles between Parani-MSP1000 and Bluetooth devices • Manual 4.2.2 Repeater Mode > page 28
Repeater Mode Typical Application: • Extend the transmission range when there is an obstacle between MSP1000 and ESD100-embedded devices • PC can manage both 3 ESD’s connected to the station and the other 3 ESD’s connected to the repeater at the same time ESD1 MSP Repeater MSP Station PC ESD2 ESD4 ESD5 ESD6 ESD3
SD B SD A SD C SD D Fig. Serial hub mode (SD A~D : Parani-SD100s) Serial Hub mode • New mode added to the list of Service Category • Menu: Serial Port Profile -> Port configuration -> Service Category • In Serial Hub mode, one SD connected to MSP1000 can communicate with multiple SD’s connected to MSP1000 can communicate with each other, 1:N multi-serial connection • Ideal for the cable replacement of RS422/485 Multi-Drop network • Manual 5.5.4 & 5.5.8
Serial Hub mode Typical Application: • Cable replacement of Master/Slave type RS422/485 Multi-drop application when Master Device is stand-alone or network-disabled. • Send the data from the scale to multiple PC’s Before : RS485 Multi-drop After : Serial Hub SD+PC A Scale PC A Scale+SD MSP Master Device Master Device SD+PC B PC B SD+PC C PC C
Data through Vertex port Fig. Vertex mode Vertex mode • New mode added to the list of Network service mode • Menu • Serial Port Profile -> Vertex configuration • Serial Port Profile -> Port configuration -> Network service -> Network service mode • A configuration to send the data from the host to connected Bluetooth devices • Manual 5.5.6 & 5.6
Vertex mode Typical Application: • Cable replacement of Master/Slave type RS422/485 Multi-drop application when Master Device is a PC or network-disabled. • Send the message from the host PC to multiple signboards Before : RS485 Multi-drop After : Vertex mode SD+Signboard PC (Master device) Signboard PC (Master device) MSP Ethernet SD+Signboard Signboard SD+Signboard Signboard
Control commands • MSP1000 used to be monitored by Telnet, SSH and HTTP. In order for MSP1000 to be monitored by programs, MSP1000 now supports TCP sockets through the port. • The Parani-MSP1000 is controllable by Control commands through 2525 TCP port • Available commands form Control port • USER admin - PASS admin • STAT - SCAN [IAC] • LIST - DISC [ID] • LOG [Line] - VER • HELP - REBOOT • QUIT • Manual Appendix D
Control commands • With PC-based program, users can monitor the status of SD’s connected to MSP1000 and disconnect the Bluetooth connection. SD MSP PC TCP 2525 port SD • - Monitoring each module of MSP1000 • - Monitoring SD connection status • Disconnect Bluetooth connection • Logging SD
Others • CF Serial modem card • Support PPP communication through Serial modem • Manual 6.2 Serial modem card configuration • Supports modem list • COMPAQ CFVFM-5614RD. • VFAT • The Parani-MSP1000 supports VFAT (windows file system format) as CF Flash memory file format. • Enhanced handling of Bluetooth FTP • When use Bluetooth FTP, you can choose CF Memory Card as Base directory • RFC-2217(Telnet COM Port Control Protocol) Support
Bug Fix List • Fixed the kernel panic problem occurring when the Parani-MSP1000 transfers many data through bluetooth module • Fixed the problem that the Portlog was not displayed in the Web correctly • SPP IN/OUT display error • Display error in Readable binary • Added Month / Date to the logging time • Fixed the problem that the text of Portlog was not cleared • Portlog Clear error on Webpage • Fixed the problem that the Portlog was not logged to CF card.
Bug Fix List • Fixed the problem that the syslogd logs '-- MARK --' to syslog server. • Fixed the problem that the Date and Time configuration was not set correctly. • Daylight saving time support