1 / 33

TIME-LIKE BARYON FORM FACTORS: EXPERIMENTAL SITUATION AND POSSIBILITIES FOR PEP-N

TIME-LIKE BARYON FORM FACTORS: EXPERIMENTAL SITUATION AND POSSIBILITIES FOR PEP-N. Roberto Calabrese Dipartimento di Fisica and I.N.F.N. Ferrara, Italy Working Group E2, SNOWMASS 2001. OUTLINE. Introduction Proton time-like form factors: near threshold PS170 (CERN)

orinda
Download Presentation

TIME-LIKE BARYON FORM FACTORS: EXPERIMENTAL SITUATION AND POSSIBILITIES FOR PEP-N

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TIME-LIKE BARYON FORM FACTORS: EXPERIMENTAL SITUATION AND POSSIBILITIES FOR PEP-N Roberto Calabrese Dipartimento di Fisica and I.N.F.N. Ferrara, Italy Working Group E2, SNOWMASS 2001

  2. OUTLINE • Introduction • Proton time-like form factors: • near threshold PS170 (CERN) • large q2 E835 (FNAL) • Neutron time-like form factors • FENICE (FRASCATI) • Narrow structure in e+e- hadrons nearNN threshold • Other baryon time-like form factors • Possibilities for PEP-N

  3. THE PHYSICS OF E.M. FORM FACTORS • Small Q2 • charge distribution magnetization current • High Q2 • valence quark distribution Test of QCD from non perturbative regime(near threshold) to perturbative regime(large Q2 )

  4. SPACE-LIKE REGION • Study of the reaction space-like • Reduced Rosenbluth cross section: • Dipolar behavior and scaling for

  5. TIME-LIKE REGION • Study of the reactions • Differential cross section • at thresholdGE=GM  uniform angular distribution • At Q2 >> 4mp2  GE contribution negligible

  6. TIME-LIKE REGION • QCD asymptotic behaviour • C and  • free parameters • at large Q2(QCD, analyticity) • ratio of neutron to proton form factor (QCD) Any prediction where the Nucleon is mostly represented in terms of valence quarks should hardly foresee

  7. PROTON FORM FACTOR (LOW Q2)PS170 exp. (CERN) Nucl.Phys.B 411 (1994), 3 • from threshold • to ECM 2 GeV • at LEAR-CERN • Selection of e+e- pairs in high hadronic background threshold Čerenkov counter + shower detector • Two bodyreconstruction  tracking system (MWPC, drift tubes) • About 2000 e+e- events above threshold

  8. PS170 DETECTOR

  9. PROTON FORM FACTOR (LOW Q2) Steep threshold behavior

  10. ANGULAR DISTRIBUTIONS Indication of decrease with energy

  11. PROTON FORM FACTOR (HIGH Q2)E835 exp. (FNAL) Phys. Rev. D60 (1999), 032002 • E835 study the charmonium spectroscopy in annihilations into electromagnetic final states: • Resonance are scanned by decelerating the antiproton beam. • Data collected in the energy range 1996/97 run (143 pb-1) 2000 run (113 pb-1)

  12. E835 experiment at Fermilab • Ideal for study of form factors as well, through the reaction • High Q2, but cross section still detectable • High luminosity • Efficient reconstruction of e+e- pairs with high invariant mass • Low background level

  13. E835 DETECTOR

  14. PROTON FORM FACTOR (HIGH Q2) The dashed line is the QCD fit. The dot-dashed line represents the dipole behavior of the form factor in the space-like region for the same values of |Q|2. The expected Q2 behaviour is reached quite early, however there is a factor of 2 between timelike and spacelike data measured at the same |Q|2.

  15. NEUTRON FORM FACTORFENICE exp. (Frascati) Nucl.Phys.B 517 (1998), 3 • from threshold • to ECM 2.5 GeV • at ADONE • (Frascati) • Antineutron annihilation in nuclei: many prong event (“star topology”) iron converters + limited streamer tubes (tracking) • Low antineutron velocity  hodoscopes for TOF measurement • Low luminosity  shield against cosmic ray background

  16. identification  isolated annihilation star + measurement • detection efficiency 10% at 2 GeV  no signal from neutron required FENICE DETECTOR

  17. NEUTRON FORM FACTOR 74 events The neutron form factor is bigger than that of the proton!

  18. NEUTRON ANGULAR DISTRIBUTION From the fit of the angular distribution

  19. PROTON FORM FACTOR ANDTOTAL HADRONIC CROSS SECTION

  20. DM2 data FNAL E687 from high energy diffractive photoproduction

  21. OPEN ISSUES • ? • Steep threshold behavior (related to narrow structure in e+e-hadrons cross section ?) All these issues can be solved at PEP-N

  22. OTHER BARYON FORM FACTOR MEASUREMENTS • , ,  -N, 0- transition form factors • No data exists (only  form factor with poor statistical accuracy) • Flavor symmetry relates the hyperon form factors to those of the nucleons  accurate prediction of flavor- symmetry breaking as test of QCD

  23. MEASUREMENT OF NUCLEON TIME-LIKE FORM FACTORS AT PEP-N • High luminosity  few hundred events/day • Asymmetric e+e- collisions up to • the neutron gets enough energy (through the Lorentz boost) to produce an hadronic shower  2 hadronic showers easy to detect in coincidence

  24. NN IDENTIFICATION AND MEASUREMENT • Angular Correlation • Time-of-flight to identify events and reject prompt photons and other fast backgrounds • Momentum analysis for pp • Calorimetric measurement

  25. KINEMATICS FOR PEP-N • Increasing larger spread in nucleon momenta larger spread in lab angles

  26. TIME OF FLIGHT

  27. NN DETECTOR REQUIREMENTS • Angular coverage between 20 and 450 in polar angle. • Detection of nucleons and antinucleons between 0.5 and 2.5 GeV/c with good efficiency. • Momentum analysis for p and p. Tracking device + Calorimeter • Tracking: measure p and p directions and momenta • Calorimeter: efficient for both neutrons and antineutrons; TOF and position of both n and n. • Distance L between detector face and interaction point: TOF and angular resolution vs acceptance

  28. N N ANGULAR DISTRIBUTIONS • cm on an event by event basis. • cm from lab • TOF (+ momentum measurement for pp) • over-constrained fit with 2 particles • fit to GE/GM

  29. GE/GM SEPARATION GE=GM and GE=0 cases for 6 weeks of data taking with 30% detection efficiency top:Ee-= 490 MeV bottom:Ee-= 330 MeV

  30. DATA TAKING TIME Time in weeks needed for an error of 15% on |GE/GM|2

  31. CONCLUSIONS • PEP-N has excellent capability in the time-like form factor field: • orders-of-magnitude better than previous experiments (for the neutron case, all the existent statistics in less than one day!) • for the first time electric and magnetic form factors will be measured separately • for the first time measurements of time-like form factors for , , …

More Related