250 likes | 413 Views
DoD’s Common Test Interface (CTI). David Droste DRS Test and Energy Management Mike Stora System Interconnect Technologies. Background. CIWG Report was Published 9/30/96 CIWG was a Government-Funded IPT
E N D
DoD’s Common Test Interface (CTI) David Droste DRS Test and Energy Management Mike Stora System Interconnect Technologies
Background • CIWG Report was Published 9/30/96 • CIWG was a Government-Funded IPT • Identified ATS Mass Termination Interface as a “Critical” Interface in Need of a Solution • Indication an Open-Architecture, Multi-Vendor, Standards Based Interface was Needed • See SCC-20/HIWG Web Site: http://grouper.ieee.org/groups/scc20/hiwg/ • IEEE Standards Coordinating Committee 20 and TC5 of the IEEE IMS Co-Sponsored the Receiver-Fixture Interface (RFI) Effort • Has Become a Family of Standards Efforts
USAF NAVY Challenge AF ATS CASS • Interoperability • Low Cost COTS Availability • Performance Repeatability • Minimum Maint/Support • Standardized Packaging • Spiral Development • Commercial and Military Applicability 1990’s 1980’s - TETS IFTE ARMY USMC General Purpose, Large, Dedicated ATE DoD Challenge to Define: Common Test Interface
IEEE-Std-1505 RFI – Step One • Defines Framework • Achieves Compatibility/Interoperability Between Manufacturers • Defines All Requirements/Qualifications/Dimensions/Electrical Parameters • Supports Scalability • Bench-Top to Multi-bay Test System Applicability • Defines Segmented vs Non-Segmented • Defines a Multitude of Connector Module Types Applicable to the RFI System
IEEE-Std-1505 RFI Segmentation Continuous (Non-Segmented) Framework Section Segmented Framework Section
Connector Modules RFI Specification - Sections (Clauses) 7-12 Give Connector Module Details • Clause 7 – 200 pin, Single Slot Signal Module • Clause 8 – Power Module Size 8 & 16 Contacts • Mixed 8/16 – 45ea. 23Amp & 4ea. 45Amp • Size 16 • 59 Contact Single Slot • 152 Contact Two Slot • Clause 9 – Coax Module (3 or 5 GHz) Size 16 Contacts • 59 Contact Single Slot • 152 Contact Two Slot • Clause 10 – Mixed Power Connector Module • 28 each 10A Contact • 16 each 20A Contact • Clause 11 –Universal 24 each Size 8 Contacts • 40GHz Coax • 45Amp Contacts • Pneumatic Contacts • Fiber Optic Contacts • Clause 12 – High-Speed Signal • 300 Contact Single Slot
IEEE-Std-1505 RFIExample Connector Modules Signal Power (Single Slot) Mixed Power Multi-slot Coax
IEEE-Std-1505 RFI • Status • Standard Released/Published April 2007 • May Be Purchased From IEEE Xplore http://ieeexplore.ieee.org/xpl/standards.jsp • User Base Already Includes Demonstration and Deployed Systems IEEE-Std-1505 Compliant Interfaces DRS Large Depot Applic - SCATE DRS Benchtop Subset ATE
Additional 1505 RFI - System Applications DRS DCCT BSTF V6 (NGATS)
IEEE-P1505.1 CTI Information Shown Subject to Change Until Standard is Balloted
IEEE-P1505.1 CTI • Need • Transportability/Rehost Capability of Test Program Sets • Requires a Standard Pin Map of Signals/Capability • Specific Implementation of: • Connector Modules Types per Slot • Segmentation • Scalability • Physical Mating Compatibility • Keying
IEEE-P1505.1 CTI - Overview • Transportability of TPSs Between ATE Systems • “New” ATE That are Legacy Upgrades • Desires for New ATE to be Able to Test Legacy Weapons Systems PLUS the New Systems • Factory to Field Test Compatibility • Required Study of Existing “Legacy” ATE Systems • CASS • TETS • IFTE • Etc., Etc., Etc. • Total of 3860 Signals are Mapped in Latest Version
P1505.1 CTI Connector Blocks • CTI Does not Utilize all the Connector Types Defined in the IEEE-Std-1505 RFI Standard • Signal pins for 3 Amp service up to 750 MHz • Coax Pins for 3 or 5 GHz performance (In either 59 single-wide and 152 Pin, double-wide Module Blocks) • Power Pins 23 Amp service or Pins (In either 59 single-wide or 152 Pin, double-wide Module Blocks)
P1505.1 Levels of Compliance • Standard Allows Levels of Compliance • Mechanical – Each Slot has a Compliant (Correct) Connector Module • Full – For Populated Slots, Signals Match the Pin Map • Categories are Defined for Scalability and Compliance • Category 1 = Slots 6 thru 9 • Category 2 = Slots 1 thru 9 • Category 3 = Slots 6 thru 24 • Category 4 = Slots 1 thru 24 • Category 5 = Slots 1 thru 29 (All/Full Compliance)
P1505.1 Compliant Keying • Categories That are Fully Compliant MUST Implement the Keying Shown Below • Non-Compliant Systems MUST Implement a DIFFERENT Keying
P1505.1 Status • Some Systems Have Implemented Draft Standard • Very Near Initiating Ballot • Latest Information From SCC-20 HIWG Meeting Held 9/15 & 9/16 is: . . . . .
IEEE-P1505.2 Two-Tier CTI
IEEE-P1505.2 Two-Tier Interface • Not all Identified Requirements Included in P1505.1 • Multi-Tier Support • B-1B • F-15 • C-17 • IAIS • LMStar • Around 1000 Unassigned Pins From 1505.1 Effort • More Research Known to be Required Two Tier Electro-Mechanical RFI
Two-Tier P1505.2 Demonstrates Vertical as Well as Horizontal Scalability Horizontal Scalability Vertical Scalability
Summary • Hardware Interfaces Working Group Is Creating A Series Of Standards To Provide The Following Benefits • Standards-based, Open-architecture Interface Providing Multi-vendor Availability For Lowest-cost To The User • Improved TPS Rehost/Transportability Though A Defined Pin-map And Segmentation Scheme • Scalability For A Range Of ATE/ATS Capability And Sizes • Standards Group is Continuing Effort to Provide Benefits to the System Integrator and the User • Everyone is Invited to Join the Group by Attending Meetings and Completing a “Bluesheet” at: http://grouper.ieee.org/groups/scc20/bluesheet.html • Learn More at the SCC-20 Web Site: http://grouper.ieee.org/groups/scc20/