This project aims to gain insights into the fate and mobility of pollutants in sediments through high-resolution profiles. The project utilizes techniques such as Dissolved Phase DGT, Solid Phase Laser Ablation ICPMS, impregnation with polyester resin and polyethylene glycol, and analysis by LA-ICPMS. The project encountered challenges with impregnation time, optimal concentration of PEG, and choice of internal standard for LA-ICPMS analysis. Validation of high-resolution profiles is being performed through comparison with other methods like synchrotron XRF.
E N D
INTERREG III: STARDUST January 2003- September 2003 VLIZ Lille, 18/09/03
Aim • Understanding of fate and mobility of pollutants in sediments • requires high resolution profiles of pollutants Dissolved phase DGT, DET Solid phase Laser ablation ICPMS Lille, 18/09/03
High resolution profiles in the solid phase • Sediment impregnation techniques: 2 techniques were tested: • Polyester resin • Polyethylene glycol Tests performed on sediments of the North Sea and the Rupel • Cutting/polishing • Analysis by LA-ICPMS Lille, 18/09/03
Vacuum impregnation in polyester resin -sectioning of core -lyophilisation -vacuum impregnation: polester, aceton, hardener Lille, 18/09/03
Vacuum impregnation in polyester resin Problems encountered: -amount of hardener, aceton; impregnation time has to be optimised for different sediment types: low porosity samples require more aceton, less hardener and longer impregantion time relatively easily solved Lille, 18/09/03
Polyethyleneglycol (PEG) impregnation • Equilibation of porewater with PEG for 3 to 5 weeks at 50°C • Lyophilisation Lille, 18/09/03
Polyethyleneglycol (PEG) impregnation Problems encountered -very slow method (3-5 weeks) -evaporation of PEG -optimal concentration of PEG depends on nature of the sample -good results for sandy marine sediment -poor results for muddy sediments, especially Rupel Lille, 18/09/03
Rupel sediment after polyester impreganation cut in 4cm sections with a diamond cutter Lille, 18/09/03
LA- ICPMS analysis compared to classical digestion-ICPMS Lille, 18/09/03
LA- ICPMS analysis Problems encountered -choice of internal standard: spiked with In, Re or major element with constant concentration (Ca,P, …) -choice of standard: better results with polyester impregnated reference sediment than with LA glass standard -validation of high resolution profiles: comparison with other methods (Synchroton XRF) are being performed Lille, 18/09/03