Trace gas vertical column retrieval using channel 8 nadir measurements: First preliminary results

Trace gas vertical column retrieval using channel 8 nadir measurements: First preliminary results. M. Buchwitz IFE/IUP University of Bremen, Germany. Level 2 BIAS Products Verification Approach:. SPCVP objective: “Verify Level 2 NRT and OL nadir products” SPCVP task: “Verify BIAS MDS”

palani
Download Presentation

Trace gas vertical column retrieval using channel 8 nadir measurements: First preliminary results

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Trace gas vertical column retrieval usingchannel 8 nadir measurements:First preliminary results M. Buchwitz IFE/IUP University of Bremen, Germany

  2. Level 2 BIAS Products Verification Approach: • SPCVP objective: “Verify Level 2 NRT and OL nadir products” • SPCVP task: “Verify BIAS MDS” • Approach: Comparison of BIAS VCDs with VCDs derived using independent algorithms (here: WFM-DOAS) • Data used: Initial verification data products made available by ESTEC via the SPCVP data base • Focus: Orbit 2338 (11-Aug-2002) covering parts of central Europe and western Africa

  3. Status of Ch.8 Lv1 and Lv2 Nadir Data Products: • Level 1c: • Spectral and radiometric calibration still preliminary • Level 2: • Quality of BIAS products suffer from imperfect calibration • Focus of the following: First WFM-DOAS results and identification of Level 1c issues to be resolved for accurate VC retrieval

  4. Examples of WFM-DOAS Fits:

  5. WFM-DOAS Derived Methane Columns:

  6. Conclusions and Recommendations • The major NIR absorbers CH4, H2O, and CO2 have been clearly identified in the spectra • The calibration / Level 0-1 processing needs to be improved for • Accurate quantitative retrieval • Identification of minor NIR absorbers (CO, N2O) • To be improved / investigated: spectral calibration (e.g., -0.3 nm shift @ ~2365 nm); scan angle dependence of radiance; dark signal correction; SMR calibration (D1 ~ 50% too low in Ch.8); missing polarisation correction, etc. • Level 1-2 processing: Significant improvement of BIAS products required