1 / 12

Application Notes for Line Testing with ET 91

Application Notes for Line Testing with ET 91. LCL Balance. Impedance. Return Loss. Near End Crosstalk. Spectrum Analyser. Frequency Response with MTTS. Automatic Master Slave Test. Micro Interruption Analysis. To learn more click on note!. ELEKTR NIKA.

patia
Download Presentation

Application Notes for Line Testing with ET 91

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Application Notes for Line Testing withET 91 LCL Balance Impedance Return Loss Near End Crosstalk Spectrum Analyser Frequency Response with MTTS Automatic Master Slave Test Micro Interruption Analysis To learn more click on note! ELEKTR NIKA

  2. LCL Balance Measurement withET 91 Two balance measuring modes are provided: ■ Measurement with one single frequency ■ Measurement in sweep mode ET 91 performs LCL measurement using the test circuit described in ITU-T Rec. 0.9 Selectable ranges Test results are available in graphic or numeric formats. ELEKTR NIKA

  3. Impedance MeasurementwithET 91 ET 91 provides impedance measurement for balanced and coaxial test objects in fix frequency or sweep modes without any external adapter. Selectable ranges Test results are available in graphic or numeric formats. ELEKTR NIKA

  4. Return Loss MeasurementwithET 91 ET 91 provides return loss measurement for balanced and coaxial test objects in fix frequency or sweep modes without any external adapter. Selectable ranges Test results are available in graphic or numeric formats. ELEKTR NIKA

  5. Near End Crosstalk measurement withET 91 ET 91 provides Near End Crosstalk measurement for balanced and coaxial test objects by transmitting on socket L2 and receiving on L1. Fix frequency or sweep modes are available Selectable ranges Test results are available in graphic or numeric formats. ELEKTR NIKA

  6. Spectrum AnalyzerMeasurement with ET 91 ET 91 provides sophisticated spectrum analyser measurements with extremely large dynamic range and high resolution. Display range: down to -140 dBm/Hz Evaluation: NORM, PEAK, AVG, SAWG Power Spectral Density (PSD) Measurement Noise Level Measurement Selectable ranges Test results are available in graphic or numeric formats. ELEKTR NIKA

  7. Quick Frequency Response Test ofET 91with Multi Tone Test Signal Selectable ranges ELEKTR NIKA

  8. Automatic Line Test in Master Slave Mode ofET 91 ▼ Click hereto see detailed results ELEKTR NIKA

  9. Detailed Test Results of Automatic Master Slave LineMeasurement All the test results are available also in numeric form and they can be transferred to PC via USB interface. ELEKTR NIKA

  10. Micro Interruption Measurement withET 91 An interruption is detected when the level of test tone drops below a designated threshold formore than 0,6 ms. The detected interruptions are included into five categories by duration ▼ Click here to see detailed results in numeric and graphic forms ELEKTR NIKA

  11. Detailed Results of Micro Interruption Measurement All the test results are available also in numeric form and they can be transferred to PC via USB interface. ELEKTR NIKA

  12. THANK YOU FOR YOUR ATTENTION !